SIXTH STAGE cont. - Wireless units only

To pair additional remote control switches:

1.  Turn the unit off at the isolation point.
2.  Restore power; for 20 seconds from restart 

the unit will be in pairing mode.

3.  Press the remote button once within the 20 

seconds and the control will pair to the unit.

4.  Successful pairing is indicated by a green 

light on the control.

N.B:

 When the battery needs replacing, unscrew 

the front cover. The battery is located on the 

back of the cover. 
Battery type - 3V Lithium, CR2032.

To change speed setting

Next press moves the unit to the 

next speed and so on. When the 

speed is chosen the LED remains 

on for a few seconds

On commission the unit will 

default to the trickle flow rate 

with heater enable on

Press button once, to indicate 

current fan speed and heater 

status. LEDs stay on constant 

for a few seconds

Содержание Mr Venty ECO2 Loft

Страница 1: ...ECO2 Loft ECO2 Twin INSTALLATION GUIDE FOR ENGINEER INSTALLER...

Страница 2: ...1 ECO2 Loft ECO2 Twin 0345 27 27 810 SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL US ON...

Страница 3: ...S AllwiringmustcomplywithBuilding Regulations and the current I E E Wiring Regulations BS7671 or the equivalent standards for your country The final installation should be examined and tested by a qua...

Страница 4: ...unit will operate continuously for 5 years and beyond without a major service Please therefore ensure that this product is treated with care and installed properly i e for the life of the building If...

Страница 5: ...damaged seek advice if the flue is in a poor state of repair Check for any flued appliance which may draw air from the loft report to the client Check for any holes in the ceilings which may allow lea...

Страница 6: ...tructions please refer to the fixing instructions Fig 1 on page 6 405mm Heater enable disable switch Heater version only volt free Subject to capacity it is possible to connect the ECO2 Loft Unit with...

Страница 7: ...ting onto the neck of the diffuser using rest of the tape provided Ensure that the diffuser is aligned correctly with the walls of the hallway Adjust if necessary Fix the diffuser in position using pl...

Страница 8: ...onds and the control will pair to the unit 4 Successful pairing is indicated by a green light on the control N B When the battery needs replacing unscrew the front cover The battery is located on the...

Страница 9: ...enable ON Auto LED stays on constant for a few seconds Heater enable OFF Auto LED flashes for a few seconds Boost Green Green Remote Control out of range Red Heater enable Red Remote Control in range...

Страница 10: ...n the positions chosen where air is required to be delivered Use the distance from the ECO2 Loft Unit to each hole to balance favour airflow i Equal air supply required diffusers equidistant from unit...

Страница 11: ...ivated and that they are still delivering air into the property In the case of a fire the system should be thoroughly checked Smoke alarm For installations in 3 storey dwellings the ECO2 Loft should b...

Страница 12: ...s specification and appearance without notice We want to hear from you Your feedback is important to us as we strive to improve our products services and overall customer experience Please email us to...

Отзывы: