O&M Instructions – Heat Pump  

 
 

ALWAYS 

 

Only use a qualified installer or qualified service person to install the door curtain. If the door curtain is 
installed by an unqualified individual, a fire, electric shocks, injury, refrigerant leakage, noise and or 
vibration may result and the product warranty will be invalidated. 
 

 

If a heat pump model is installed in a small room, take appropriate measures to prevent the refrigerant 
from exceeding the concentration limit if it leaks. Consult the dealer who supplied the heat pump outside 
unit when implementing the measures. Accumulation of highly concentrated refrigerant may cause an 
oxygen deficiency accident.   
 

 

When transporting the door curtain, take care not to hold the bands around the packing carton. Injury 
may result if the bands should break. Wear shoes with additional protective toe caps. 
 

 

Check the structure is capable of supporting the weight of the unit. The designated hanging bolts M10 or 
greater should be used at enough strong places to support the weight of the unit. If the strength is not 
enough, the unit may fall down resulting in injury. 

 

 

Check the unit will cover the full width of the door with minimum 100mm overlap each side. Mount the 
unit as close to the door as possible. 

 

 

Note that the maximum mounting height dimension is from fixed floor level to the discharge grille. 

 

 

Refer to the charts for dimensions and weights. 

 

 

Ensure that a suitable fused isolated earthed and lockable power supply is available (not supplied). The 
isolator must be located at a height of between 0.6m and 1.9m above the service level. (See charts above 
for rating and type). The height of the service level will be dependent upon final fixed position of door 
curtain and type and size of access equipment used to service product. As a guide consider the bottom of 
the air curtain to be the datum. 
 

 

Provide a suitable padlock for the off-switch locking to ensure that the isolated power supply is not 
accidentally switched on during installation or maintenance. 

 
 

NEVER 

 

 

Install the door curtain in a hazardous environment or areas where explosive atmospheres may be 
present. If a combustible gas leaks and becomes concentrated around the unit a fire may occur. This 
equipment is not intended to be used in hazardous environments. 
 

 

Obstruct the filter (minimum recommended free space to obstruction 200mm). 
 

 

Obstruct or cover the linear blade supply air grille. 

 
 
 
 
 
 
 
 
 
 
 

10.0 Installation 
 

 

 

 

Содержание ES D15-HP

Страница 1: ...High Wycombe Bucks HP12 3BX Tel 01494 525 342 Web www envirotec co uk Unit Type ES Type D15 HP RAV SP1104AT E Unit Type ES Type D15 HP RAV SP1104AT E_2016v1 Installation Operation Maintenance Manual...

Страница 2: ...t available to order 9 9 0 Filter Specification and Size 9 10 0 Installation 10 11 0 Operation 14 12 0 Wiring Schematics 15 13 0 Commissioning 18 13 0 Troubleshooting 18 14 0 Service Maintenance Instr...

Страница 3: ...ally hazardous When handling operating or carrying out maintenance on the unit personnel must use safe engineering practices and observe all relevant local health and safety requirements and regulatio...

Страница 4: ...used ladders towers etc are isolated from passing human traffic by the use of an appropriate barrier notice system Any barriers used should be positioned at a suitable distance to remove risk of injur...

Страница 5: ...ow the installation instructions carefully to ensure correct and safe installation of the product Enviroscreen ES Type D Free hanging via drop rods front access to air intake filter Maintenance via fr...

Страница 6: ...V SP1104AT E Heating Capacity kW 2 4 13 0 Heating Power Input kW 2 52 Operating Range Cooling Heating C 43 to 15 15 to 15 Standard Air Flow l s 1683 Standard Air Flow m3 h 6060 Sound Pressure Level Co...

Страница 7: ...S D 15 1500 1470 87 1 0 184 2 5 7 5 0 63 11 20 A 317 340 B Plan View 46 160 53 225 72 29 1 x 20mm 1 x 25mm Coil connections 22mm plain copper tails Cable Entry Points Enviroscreen Type ES D Fixing det...

Страница 8: ...25 Mounting bolt hole 12 17 long hole Mounting bolt hole 12 17 U shape hole B legs Details of A legs Details of B legs A legs 55 95 2 1 64 1 65 7 83 7 Knockout for downward piping Z views 655 121 534...

Страница 9: ...ower Input kW Maximum Operating Current Amp ES 15 SM1104AT E TO 2 8900 I1 SVB CC05 1 3 1 14 4 For isolator sales contact Envirotec on 01494 525342 or sales envirotec co uk quoting model number and ser...

Страница 10: ...Check the unit will cover the full width of the door with minimum 100mm overlap each side Mount the unit as close to the door as possible Note that the maximum mounting height dimension is from fixed...

Страница 11: ...ids available to allow for a safe installation Remove front panel by removing fixing screws to access fixing points Replace screws into holes for safe keeping during installation Make sure that the fi...

Страница 12: ...ince failure to carry out the work properly may result in electric shocks and or electrical leaks When connecting electrical wires repairing the electrical parts or undertaking other electrical jobs w...

Страница 13: ...Megger to check the resistance is 2M or more between the charge section and the non charge metal section Earth section If the resistance value is low a disaster such as a leak or electric shock is cau...

Страница 14: ...eaker and contact a qualified service person Fan Speed button 1 Select Fan speed by pressing 1 Unit may be single speed only If this is the case then this button will have no use Adjust the desired se...

Страница 15: ...earth screw 2 Pole Isolator L1 N 220 240V AC Single Phase Neutral Earth RAV SM1104AT8 E 3 Pole Isolator All A B wiring to be 2 Core Twisted Screened 220 220V AC Single Phase 3 Core Earth BMS Input Dev...

Страница 16: ...urtain earth screw Outdoor Unit earth screw 2 Pole Isolator L1 N 220 240V AC Single Phase Neutral Earth RAV SM1104AT8 E 3 Pole Isolator All A B wiring to be 2 Core Twisted Screened 220 220V AC Single...

Страница 17: ...Door Curtain 1 Remote Control RBC AS41E A B A B All A B wiring to be 2 Core Twisted Screened BMS Input Device Optional Extra Envirotec Drawing Ref GSS1124 Master Slave Door Curtain 2 A B Door Curtain...

Страница 18: ...electrical terminations tight Control panel Switch and unit Checks with power applied Only undertake these test once all covers have been refitted and unit is electrically safe Fan speeds correct if...

Страница 19: ...g diagram is available Climb onto or place objects on top of the door curtain You may fall or objects may fall off and result in injury 14 2 Service ALWAYS Inspect for mechanical and electrical defect...

Страница 20: ...is available This will avoid costly damage 14 7 Washable filters where fitted ALWAYS Inspect the unit after is has been running for two weeks to establish a time scale within which the filters should...

Страница 21: ...Type B Unit Type C Toshiba ES Type with RAV Super Digital Inverter Heat Pump Remark the installer is obligated to ensure that all of the heating system complies with the PED directive If modifications...

Страница 22: ...EQYLURWHF WG HVERURXJK 3DUN 5RDG LJK FRPEH XFNLQJKDPVKLUH 3 DOO PDLO IUHVKWKLQNLQJ HQYLURWHF FR XN...

Отзывы: