Doc. No. MO-RKN-3062
Version 1.5: Sep. 08, 2010
21 (38)
ALERTS AND ALARMS
ALERTS AND ALARMS
Alerts and Actions to be Taken
If any
alert is activated the yellow indicator is flashing on the control unit and the alert is shown on
the control unit display. Refer to section "Control unit operation".
"Battery below 9.5 V"
Reason:
The battery voltage is below 9.5 V.
Action:
Check the battery level immediately. The batteries can be used down to 9.0 V; the
purpose of the alert is to inform that the battery level is going towards 9.0 V and that
change of batteries should be considered depending on remaining shipping time. Refer
to section "Control unit operation".
"Fan 1 Warning"
Reason:
If the control unit has detected a "Fan 1 Error" it will be indicated as an alarm.
However if the fan subsequently is detected as working, the fan alarm is cleared and
replaced by this "Fan 1 Warning" alert. This alert is raised permanently as a need-
for-inspection indication (after shipment) and can only be cleared by authorized
personnel.
Action:
The shipment can proceed as normal. After shipment it is recommended to inspect
the container and have the alert cleared by authorized personnel.
"Ambient Temp Out of Spec"
Reason:
The ambient temperature is out of specification (above +40°C / +104°F).
Action:
Move the container to an area with temperature within the specifications. Refer to
section "Limits, ambient conditions".
Note!
Do not use the ambient temperature displayed by the control unit as a reference for verifying
ambient temperature conditions.