LIMITS, AMBIENT CONDITIONS
• The container is designed to maintain the temperature of the cargo shipped by cooling or
heating the air inside the container.
The following conditions must apply for the container to work properly:
2.1
PRE-CONDITIONING OF CARGO
• The container does not have battery capacity to cool down or heat up a large quantity of
cargo.
• The container is designed to maintain the temperature of the cargo. It is therefore important
that the cargo is pre-conditioned correctly.
2.2
MINIMUM OPERATING TIME - FULLY CHARGED CONTAINER
• For a +5°C (+41°F) container set temperature the minimum operating time without
recharging the batteries is 30 hours provided that the ambient temperature is between -10°C
and +30°C (+14°F and +86°F). However, the operating time will increase if the ambient
temperature is closer to the container set temperature of the cargo space.
• For other container set temperatures contact Envirotainers Customer Care team for advice:
2.3
EXPOSURE TO AMBIENT TEMPERATURE ABOVE +30°C (+86°F)
The container can maintain the temperature in the loading area even if the ambient temperature
is b30°C and +40°C (+77°F and +104°F), but the battery consumption will increase,
and the container operating time will therefore decrease.
For example, if the ambient temperature is +35°C (+95°F) and the container set temperature is
+5°C (+41°F), the container can maintain the temperature but the container operating time will
be reduced.
NOTE!
The container remains operational b40°C and +50°C (+104°F and 122°F), but may not
be able to maintain the container set temperature.
5 (40)
Doc No:
MO-RAP-3079
Revision:
17
State:
Released
Release Date:
2019-04-25
Approved By:
maxf