4
For Illustration Purposes Only:
On-Site Assembly Required
due to shipping weight for all larger systems,
tank, all tank contents and valve must be assembled on site.
Please review the simple steps for proper assembly.
overall
height
79”
tank
height
65”
self leveling
base
tank width 16”
Flexible Connections Required:
Stainless steel corrugated water connectors, PEX or PVC Sch 40 have a flexible capability that may assist with issues where the
rough and finish measurements are slightly off or where pressure surges/spikes or back pressure occur. This flexible connection may
prevent tank and valve issues where rigid or hard pipe create problems over time. This is a requirement of the tank manufacturer
and is stated on the label affixed to every tank. Perform all plumbing according to state or local codes.
Drain Line Air Gap Required and Spring Check Highly Recommended:
Please see information for proper drain line installation in the Product and Installation guide
depth: minimum 24” needed for proper installation
Complete setup, install and startup of these systems can be found in this Product and Installation Guide
*Not Supplied:
Due to variations in installations, length and sizing needed for pipe connections to and from the system (see flexible requirement) and drain line are not supplied
For Illustration Purposes only:
Corrugated flexible stainless not supplied
CAUTION:
all measurements are
approximates and system
heights may have
variances up to 2”.
Pictured:
eWs-1665-2, CWl-1665-2
weight dry: approx 350 lbs
weight wet: approx 850 lbs
Pictured:
eWs-CC-2472-2, CWl-CC-2472-2
depth: minimum 28” needed for proper installation
overall
height
88”
tank
height
72”
weight dry: approx 650 lbs
weight wet: approx 2,400 lbs
tank width 24”
installation dimensions
- Model #’s eWs-1665-2, CWl-1665-2, eWs-CC-2472-2, CWl-CC-2472-2
Valve
(front view)
CauTIoN: If installing other equipment in addition to this system - Contact customer service for proper order of installation
Valve
(front view)
height
to center
incomng
68-3/4”
height
to center
outgoing
68-3/4”
height
to center
drain
73”
height
to center
incomng
78”
height
to center
outgoing
78”
height
to center
drain
82-1/4”
Plumber installed
bypass is required
2.0” brass close or shoulder
nipples, 2.0” corrugated flex-
ible stainless, all incoming/
outgoing piping and 3 ball
valves are not supplied
For Illustration
Purposes Only:
This is an example of 3 valve
bypass using corrugated flexible
stainless to make the final
connections with the valve.
Configuration may vary
Содержание CWL-1665-2
Страница 18: ...18...