SIMPLE STEPS FOR A CORRECT INSTALLATION AND HAPPY CUSTOMER

  ......................................  

  2

INSTALLATION DIMENSIONS FOR 1665-2 AND 2472-2 SYSTEMS     

   ..................................................  

  4

ASSEMbLY INSTRUCTIONS     

   ................................................................................................................  

  5

 

IMPORTANT SAFETY INFORMATION – All Systems

 

Instructions before Using

 

........................................................................................................ 

  6

LOCATION AND SETUP - All Systems

 .......................................................................................................  

  7

 

Unpacking and Inspection 

 

Where to Install the system

 

drain location

 

outside Installation (where applicable)

 

INSTALLATION INSTRUCTIONS - All Systems

  

 

Plumbing Connections and bypass 

........................................................................................... 

  8

 

drain line 

.................................................................................................................................. 

 11

 

electrical Connection  ..................................................................................................................... 

 12 

START-UP PROCEDURES - All Systems

 

set the Time of day 

..................................................................................................................... 

 13 

 

Tank Fill Slowly .................................................................................................................................. 

 13

 

Flushing the system Procedure  ........................................................................................................ 

 14

 

last steps before leaving the system  ........................................................................................... 

 15

 

 

repeat Flushing (if needed)

 

 

open outlet side of bypass

 

 

system ready for use

 

 

run Water throughout the Home 

 

 

 

Product blow-out (for illustration purposes) 

.............................................................................. 

 17 

 

 

Valve Parts blow-out  ........................................................................................................................ 

 18 

 

Warranty  

.................................................................................................................................. 

 19 

 

Back Cover with EWS Contact Information ....................................................................................... 

 20

For additional installation information and videos, troubleshooting and questions & answers - please visit www.ewswater.com 

or email the eWs crew @ [email protected] or call us @ 702.256.8182

 during normal business hours, Monday through Friday from 8am to 4:30pm pacific standard time 

www.ewswater.com  o. 702.256.8182; (m-f; 8:00am-4:30pm; PsT)  f. 702.256.3744  e-mail. [email protected]

table of contents

CoMPlIaNCes, CalIForNIa CoMPlIaNCes, ProduCT guIdelINes, FaCTory PreParaTIoN, 

ProduCT PerForMaNCe aNd geNeral TerMs aNd sTaNdard CoNdITIoNs oF sale are 

aVaIlable uPoN requesT or PublIsHed oN WWW.eWsWaTer.CoM 

Содержание CWL-1665-2

Страница 1: ...ing line size Model Numbers Home and Commercial Water Filtration Conditioning Systems EWS 1665 2 EWS CC 2472 2 Home and Commercial Water Filtration Systems CWL 1665 2 CWL CC 2472 2 Retain this Product...

Страница 2: ...alve closed Page 13 6 Allow system to start itself up and self clean the filtration media Page 14 7 Open valve on the outgoing line keep bypass closed and put system in service position and flush wate...

Страница 3: ...if needed Open Outlet Side of Bypass System Ready for Use Run Water throughout the Home Product Blow Out for illustration purposes 17 Valve Parts Blow Out 18 Warranty 19 Back Cover with EWS Contact In...

Страница 4: ...ions in installations length and sizing needed for pipe connections to and from the system see flexible requirement and drain line are not supplied For Illustration Purposes Only Corrugated flexible s...

Страница 5: ...lbs of underbed grey pea gravel with the Black Funnel and load all materials until box is empty Caution Slowly fill and make small adjustments as needed to make sure Riser Tube is straight up and dow...

Страница 6: ...d system to conform with all codes and ordinances Installation location Install system in a protected area Always connect the system to the main water supply pipe feeding the entire home before the wa...

Страница 7: ...ID and install a non restrictive spring check valve in drain line within the first 2 of the drain port if drain line exceeds 20 in total length or drain line flows over 5 above the height of the drai...

Страница 8: ...rts or boxes lying around Once filled with water correcting something can be a problem 5 Locate water line or pipe to be cut and make sure of direction of water flow CAUTION Do not cross connect or pl...

Страница 9: ...the main supply before the system or a check valve on the outlet side of the the system water heater will require expansion tank to prevent backflow and excessive head pressure may be required Locatio...

Страница 10: ...ections with the valve Configuration may vary recommendation Let s build the bypass against the wall use less space and make the correct connections 1 Build your bypass 2 Secure against the wall 3 Con...

Страница 11: ...n drain line within the first 2 of the drain port to prevent possible back flow minimum 1 air gap normal flow 7 Plumb rigid tubing only PVC recommended if code applicable directly to the 3 4 FNPT bras...

Страница 12: ...y ground system to conform with all codes and ordinances 4 _ SRV 00 00PM REGEN IN 06 DAYS Set Up Button Adjusts Clock Up Adjusts Other Settings as needed Set Down Button Adjusts Clock Down Adjusts Oth...

Страница 13: ...out filtered to home bypass closed valve closed clear the plumbing lines and connections 11 1 Keep the inlet and outlet closed to and from the system 2 Turn on main water supply 3 Go to a tub best or...

Страница 14: ...Pre set next backwash in 6 days and correct time of day CYCLE 2 00 04 59 BRINE SLOW RINSE CYCLE 3 00 09 59 RAPID RINSE 4 _ SRV 00 00PM REGEN IN 06 DAYS Start Up TO Flush the system 13 Press the Extra...

Страница 15: ...rain water remains grey Press the Extra Cycle Button and repeat the flushing sequence until the water from the drain line runs clear minimum 1 air gap look for clear water coming from the drain Extra...

Страница 16: ...y Water If water appears cloudy allow to run for several more minutes until all air is expelled or until clear NOTE Pre existing conditions older homes or facilities heavy sediment If location is a ye...

Страница 17: ...utlet Valve Inlet Front View Fully Ported 2 0 Valve 4 valve base Note Freeboard Top 1 3 of tank is empty for proper backwash and lift of filtration media for the automatic self cleaning of the system...

Страница 18: ...18...

Страница 19: ...bsites and in all service guides supplied with all product Limited Warranty EWS Inc a Nevada corporation hereby warrants all products to the original consumer purchaser to be free from defects in mate...

Страница 20: ...bing Wholesale Supply Locations and their building plumbing HVAC and service contractors and Authorized Online Distributors EWS is a Proud Contributor and Sponsor of Organizations Dedicated to Improvi...