In the illustration shown the flexible piping would cross in 

order for the correct connection into the inlet side and the 

outlet side of this valve. 

Your configuration may vary

IllusTraTIoN aboVe rePreseNTs THe serVICe PosITIoN:

In & out valves are open and bypass valve in closed position

CAUTION: 

 all valves should remain closed until startup procedure

in raw 

water supply

bypass

closed

connect to 

inlet

connect to 

outlet

Plumber installed 

bypass is required 

2.0” brass close or shoulder nipples, 2.0” corrugated flexible 

stainless, all incoming/outgoing piping and 3 ball valves are 

not supplied

FOR ILLUSTRATION 

PURPOSES ONLY: 

This is an example of 3 valve bypass using corrugated flexible stainless to make the final connections with the valve. 

Configuration may vary 

RECOMMENDATION 

leT’s buIld THe byPass agaINsT THe Wall, 

use less space and make the correct connections:

1.   build your bypass.

2.   secure against the wall. 

3.   Connect 24” flexible corrugated stainless to your bypass. 

4.   Create a gentle curve in the flexible piping to avoid rigid connection.

5.  Using 2.0” close or shoulder nipples connect your flexible piping to the proper inlet and outlet on the valve

NOTE:

  Valve has flow in & out direction  arrows on the brass inlet & outlet

If you build a bypass and secure to the wall, using 

the required flexible piping will allow you to move the 

system close to the wall. 

This will also allow you to move the flexible piping to 

connect to the proper inlet and out of the valve and 

assist with the installation where rough plumbing and 

finish measurements are slightly off 

bypass - big picture with some great information

out filtered to 

home or facility

Содержание CWL-1665-2

Страница 1: ...ing line size Model Numbers Home and Commercial Water Filtration Conditioning Systems EWS 1665 2 EWS CC 2472 2 Home and Commercial Water Filtration Systems CWL 1665 2 CWL CC 2472 2 Retain this Product...

Страница 2: ...alve closed Page 13 6 Allow system to start itself up and self clean the filtration media Page 14 7 Open valve on the outgoing line keep bypass closed and put system in service position and flush wate...

Страница 3: ...if needed Open Outlet Side of Bypass System Ready for Use Run Water throughout the Home Product Blow Out for illustration purposes 17 Valve Parts Blow Out 18 Warranty 19 Back Cover with EWS Contact In...

Страница 4: ...ions in installations length and sizing needed for pipe connections to and from the system see flexible requirement and drain line are not supplied For Illustration Purposes Only Corrugated flexible s...

Страница 5: ...lbs of underbed grey pea gravel with the Black Funnel and load all materials until box is empty Caution Slowly fill and make small adjustments as needed to make sure Riser Tube is straight up and dow...

Страница 6: ...d system to conform with all codes and ordinances Installation location Install system in a protected area Always connect the system to the main water supply pipe feeding the entire home before the wa...

Страница 7: ...ID and install a non restrictive spring check valve in drain line within the first 2 of the drain port if drain line exceeds 20 in total length or drain line flows over 5 above the height of the drai...

Страница 8: ...rts or boxes lying around Once filled with water correcting something can be a problem 5 Locate water line or pipe to be cut and make sure of direction of water flow CAUTION Do not cross connect or pl...

Страница 9: ...the main supply before the system or a check valve on the outlet side of the the system water heater will require expansion tank to prevent backflow and excessive head pressure may be required Locatio...

Страница 10: ...ections with the valve Configuration may vary recommendation Let s build the bypass against the wall use less space and make the correct connections 1 Build your bypass 2 Secure against the wall 3 Con...

Страница 11: ...n drain line within the first 2 of the drain port to prevent possible back flow minimum 1 air gap normal flow 7 Plumb rigid tubing only PVC recommended if code applicable directly to the 3 4 FNPT bras...

Страница 12: ...y ground system to conform with all codes and ordinances 4 _ SRV 00 00PM REGEN IN 06 DAYS Set Up Button Adjusts Clock Up Adjusts Other Settings as needed Set Down Button Adjusts Clock Down Adjusts Oth...

Страница 13: ...out filtered to home bypass closed valve closed clear the plumbing lines and connections 11 1 Keep the inlet and outlet closed to and from the system 2 Turn on main water supply 3 Go to a tub best or...

Страница 14: ...Pre set next backwash in 6 days and correct time of day CYCLE 2 00 04 59 BRINE SLOW RINSE CYCLE 3 00 09 59 RAPID RINSE 4 _ SRV 00 00PM REGEN IN 06 DAYS Start Up TO Flush the system 13 Press the Extra...

Страница 15: ...rain water remains grey Press the Extra Cycle Button and repeat the flushing sequence until the water from the drain line runs clear minimum 1 air gap look for clear water coming from the drain Extra...

Страница 16: ...y Water If water appears cloudy allow to run for several more minutes until all air is expelled or until clear NOTE Pre existing conditions older homes or facilities heavy sediment If location is a ye...

Страница 17: ...utlet Valve Inlet Front View Fully Ported 2 0 Valve 4 valve base Note Freeboard Top 1 3 of tank is empty for proper backwash and lift of filtration media for the automatic self cleaning of the system...

Страница 18: ...18...

Страница 19: ...bsites and in all service guides supplied with all product Limited Warranty EWS Inc a Nevada corporation hereby warrants all products to the original consumer purchaser to be free from defects in mate...

Страница 20: ...bing Wholesale Supply Locations and their building plumbing HVAC and service contractors and Authorized Online Distributors EWS is a Proud Contributor and Sponsor of Organizations Dedicated to Improvi...

Отзывы: