Environmental Instruments Fluoroprobe FL-2-S0 Скачать руководство пользователя страница 2

 

Fluoroprobe 

 

TABLE OF CONTENTS 

 
 

Section 1

   Product Description  

 

 

Section 2

   Control Settings - Description  

 

Control and Set Points  

 

 

Section 3

   Introduction to Calibration  

 

1.  Air Saturated Water Calibration  

2.  Zero Calibration  

3. Air 

Calibration 

4.  Calibration Using Hand Held DO Meter  

5.  Probe and Sensor Maintenance  

6.  Troubleshooting and Tips  

 

 

Figure -1

   Installation Illustration 

 

 

Figure -2

   Face Plate – Descriptions/Drawing  

 

 

Figure -3

   Relay Description - Terminal Location  

 

 

Figure -4

   4 to 20 mA Board Drawing/Connection  

 

 

Figure -5

   Fluoroprobe Specifications  

 

 

Figure -6

   Calibration Tables and Altitude Correction Factors  

 

 

Figure -7

   Warranty 

Содержание Fluoroprobe FL-2-S0

Страница 1: ...O M Manual MODEL FL 2 S0 NEW WEBSITE WWW thefluoroprobe com ENVIRONMENTAL INSTRUMENTS LLC 144 Industrial Park Drive SuiteA 3 Waynesville NC 28786 From Process Control Services Phone 02 9319 1808 Fax...

Страница 2: ...ibration 3 Air Calibration 4 Calibration Using Hand Held DO Meter 5 Probe and Sensor Maintenance 6 Troubleshooting and Tips Figure 1 Installation Illustration Figure 2 Face Plate Descriptions Drawing...

Страница 3: ...tional solar powered brush for cleaning the sensor can be ordered mounted on a float for remote or aquaculture applications Unlike polargraphic and Galvanic probes the FluoroprobeTM sensor does not co...

Страница 4: ...ibrating The FluoroprobeTM is very stable and the longer it stays in the water the better The FluoroprobeTM is calibrated before shipping to a known zero 0 ppm standard and air saturated water 8 47 D...

Страница 5: ...owth or debris covering the sensor will cause oxygen reading to slowly fall to zero the only maintenance needed is once a month toothbrushing Many aeration basins never have this growth problem 1 Air...

Страница 6: ...t twenty 20 minutes Do not air calibrate if air and water temperatures are or 10o C difference Using the enclosed pressure altitude chart fig 3 and the altitude of the location where the unit will be...

Страница 7: ......

Страница 8: ......

Страница 9: ...1 2 3 4 1 2 3 4 A B C D A B C D Title Size Number Rev Date File Name Drawn By Sheet of RELAY LOCATION RELAY 3 10A 250VAC RELAY 2 10A 250VAC RELAY 15A 250VAC TERMINAL POS WARRANTY ZERO LEAVE ALONE...

Страница 10: ...ile Name Drawn By Sheet of THIS POT ADJUSTS THE 4mA AT 0 PPM THIS POT ADJUSTS THE SPAN CAN BE ADJUSTED FOR 20mA AT 10 PPM TO 19 99 PPM BLUE WIRE 4 20 WHITE WIRE 4 20 NOTE MAX LOOP RESISTANCE IS 550 oh...

Страница 11: ...MODEL FL 2 SWING OUT WIRING DIAGRAM LINE NEU 4 20 4 20 Earth RELAY 1 RELAY 1 RELAY 2 RELAY 2 230 VAC RELAY 3 RELAY 3...

Страница 12: ...0 2ppm Sensor Lifetime Based solely upon the application environment and the effect on Silicone Rubber 3 year Sensor warranty on approved applications 4 20 mA Max Resistance 550 ohms Features Tempera...