20
Initial Installation
QUALIFIED INSTALLERS ONLY
c
LeaRances
to
c
ombustibLes
:
A. Sidewall to unit
11 inches (27.9 cm)
B. Backwall to unit
2.5 inches (6.35 cm)
C. Corner to unit
2.5 inches (6.35 cm)
D. Ceiling
60 inches above floor (152.4 cm)
E. Floor
(hard wood and linoleum) 0 inches
Note: When installing on a carpeted surfaces a non-
combustible hearth pad must be used.
Minimum Alcove Dimensions:
Width
48 inches (121.9 cm)
Height
60 inches (152.4 cm)
Depth (max)
24 inches (60.96 cm)
CLEARANCES MUST BE SUFFICIENT TO ALLOW ACCESS FOR MAINTENANCE AND SERVICE.
P
Lanning
y
ouR
i
nstaLLation
:
When planning your installation, it will be necessary to select the proper length of vent pipe for your
particular requirements. It is important to note when passing through a wall, the maximum allowable
wall thickness is 10 inches (25.4 cm), 1½ inches (3.8 cm) clearance to combustibles must be maintained.
Select the amount of vertical rise desired for “vertical-to-horizontal” type installations. To determine
the length of vent pipe required for vertical installations, measure the distance from the appliance flue
outlet to the ceiling, the ceiling thickness, the vertical rise through the attic or second story, and allow
for sufficient vent height above the roof line. For two story applications, a fire stop is required at each
floor level. If an offset is needed in the attic, additional pipe and elbows will be required. To connect the
venting system to the appliance flue outlet, a twist-lock adapter is built into the appliance at the factory.
Refer to
I
nItIal
I
nstallatIon
- v
ent
c
onfIguratIon
and
r
estrIctor
s
ettIngs
for venting parameters.
B
A
Front
Back wall
Side w
all
C
C
Fr
on
t
Adjacent wall
A
djac
en
t w
all
Figure 15: Clearances to combustibles.