DIRECT VENT: 

This type is identified by the suffix DV. This appliance draws all of its air for combustion from 

outside the dwelling, through a specially designed vent pipe system.
This appliance has been tested and approved for installations from 0 feet to 4500 feet (1372 m) above sea level.

BV: 

This Vented appliance draws all of its combustion air from the dwelling and must be vented using listed B or L 

vent. May also be vented through a conventional chimney using a chimney liner kit.
This appliance has been tested and approved for installations from 0 feet to 4500 feet (1372 m) above sea level.

In the USA:

 The appliance may be installed at higher altitudes. Please refer to your American Gas Association 

guidelines which state: the sea level rated input of Gas Designed Appliances installed at elevations above 2000 

(610 m) feet is to be reduced 4% for each 1000 feet (305 m) above sea level. Refer also to local authorities or 

codes which have jurisdiction in your area regarding the de-rate guidelines.

In Canada

: When the appliance is installed at elevations above 4500 feet (1372 m), the certified high altitude 

rating shall be reduced at the rate of 4% for each additional 1000 feet (305 m).

• 

This appliance has been tested by OMNI - Test Laboratories, Inc and found to comply with the established 

VENTED GAS FIREPLACE HEATER standards in CANADA and the USA as follows:

VENTED GAS FIREPLACE HEATER (SIENNA BV/DV; NG/LPG)

TESTED TO: ANSI Z21.88a-2003/CSA 2.33a-2003 VENTED GAS FIREPLACE HEATERS

CAN/CGA 2.17-M91 GAS-FIRED APPLIANCES FOR HIGH ALTITUDES

CSA P.4.1-02 TESTING METHOD FOR MEASURING ANNUAL FIREPLACE EFFICIENCY

 

4

Codes And Approvals

This ENVIRO SIENNA Fireplace: 

•  Has  been  certified  for  use  with  either  natural  or  propane  gases.  (See  rating 

label.)

• Is not for use with solid fuels.

• Is approved for bedroom or bed sitting room. (

IN CANADA

: must be installed 

with a listed wall thermostat. 

IN USA

: see current ANSI Z223.1 for installation 

instructions.)

• Installation must conform with local codes or, in the absence of local codes, with 

the National Gas and Propane Installation Code, CSA B149.1 in Canada, or the 

National Fuel Gas Code, ANSI Z223.1/NFPA 54 in the USA.

• Must be properly connected to an approved venting system and not connected to 

a chimney flue serving a separate solid fuel-burning appliance.

• Is not approved for closet or recessed installations.

IMPORTANT  NOTICE  (Regarding  first  fire  up):

  When  the  unit  is  turned  on 

for the first time, it should be turned onto high without the fan on for the first 4 

hours. This will cure the paint, logs, gasket material and other products used in 

the manufacturing process. It is advisable to open a window or door, as the unit 

will start to smoke and can irritate some people. After the unit has gone through 

the first burn, turn the unit off including the pilot, let the unit get cold then remove 

the glass door and clean it with a good gas fireplace glass cleaner, available at 

your local ENVIRO dealer.

Содержание Sienna BV

Страница 1: ...nstructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING If the informa...

Страница 2: ...o is unfamiliar with the stove to operate it To prevent injury if the pilot or pilot and burners have gone out on their own open the glass door and wait 5 minutes to air out before attempting to re li...

Страница 3: ...l Conversion 11 Initial Installation 13 Clearances to Combustibles 13 Minimum Fireplace Size 14 B Vent Model 14 Automatic Flue Gas Spill Switch B Vent Model Only 14 Direct Vent Model 15 Preparing Your...

Страница 4: ...GAS FIREPLACE HEATER SIENNA BV DV NG LPG TESTED TO ANSI Z21 88a 2003 CSA 2 33a 2003 VENTED GAS FIREPLACE HEATERS CAN CGA 2 17 M91 GAS FIRED APPLIANCES FOR HIGH ALTITUDES CSA P 4 1 02 TESTING METHOD F...

Страница 5: ...und 14 1 2 369 mm 14 3 8 365 mm From Back Sensor To Surround 17 1 16 434 mm 18 11 16 474 mm 33 x 46 840 x 1930 mm Surround with Trim From Flue To Trim 13 1 4 337 mm 13 1 16 333 mm From Back Sensor To...

Страница 6: ...rim 33 338 mm 20 5 8 523 mm 22 3 4 577 mm 22 11 16 576 mm With Trim 46 1 8 1171 mm Without Trim 46 1168 mm 21 533 mm 13 1 16 333 mm 1 3 8 36 mm 17 3 8 441 mm Shown B Vent with 33 x 46 84cm x 193 cm su...

Страница 7: ...will not allow the pilot burner to be relit until the thermocouple has cooled If the knob does not pop up when released stop and immediately call your service technician or gas supplier If the pilot d...

Страница 8: ...e blower off turn the knob COUNTER CLOCKWISE until it clicks off Figure 6 It is advisable not to operate the blower below 1 3 speed as it puts a strain on the windings of the blower and running the bl...

Страница 9: ...the logs carefully as they are very fragile Gently remove all the embers and rock wool and place on a paper towel Vacuum the bottom of the firebox thoroughly Carefully clean any dust off the logs and...

Страница 10: ...igure 8 Lift the bottom of the door up and remove from unit see Figure 9 CAUTION GLASS MAY SEPARATE FROM DOOR remove the complete gas and electrical tray assembly from the firebox ensuring that no wir...

Страница 11: ...ons is not followed exactly a fire explosion or production of carbon monoxide may result causing property damage personal injury or loss of life The qualified service agency is responsible for the pro...

Страница 12: ...d to pay special attention when installing the burner that the venturi adjustment rod is properly installed into the venturi adjustment piece welded to the burner venturi tube 9 Reconnect the main gas...

Страница 13: ...minimum height of 43 1092 mm from the bottom of unit If installed at floor level a minimum 16 406 mm non combustible material must be installed in front of the unit If installed on a 12 305 mm wide h...

Страница 14: ...AS SPILL SWITCH B VENT MODEL ONLY NOTE This heater must be properly connected to a venting system This heater is equipped with a vent safety shutoff system designed to protect against improper venting...

Страница 15: ...ue before installing the stove Failure to do so may result in fumes or dirt being blown into the room and may cause a fire leading to death or serious injury 1 Remove the unit from the box and remove...

Страница 16: ...State and local building codes and has been constructed of non combustible materials This appliance must not be connected to a chimney flue serving a separate solid fuel burning appliance Before start...

Страница 17: ...learance to a building opening or combustion air inlet of another appliance except with the approval of the authority having jurisdiction for the following reduced clearances 9 in 0 23 m Exception for...

Страница 18: ...three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong outlet DO NOT cut or remove the grounding prong from this plug C...

Страница 19: ...piping system at test pressures equal to or less than 1 2 psi 3 5 kPa The unit must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure te...

Страница 20: ...Ensure the tabs are under the brackets at the back and the holes at the front line up Secure into place with the two 2 T 20 screws at the front of the unit 4 Disconnect the two 2 blue wires at the ope...

Страница 21: ...r tighten the screw in each corner bracket in the side trims then tighten the top trim 2 Slide the two 2 attached trim pieces onto the surround panel 3 Attach the other side trim piece to the top trim...

Страница 22: ...re 32 First Stage Log Set Installation Figure 33 Second Stage Log Set Installation Figure 32 The left log and the right log both have two 2 holes in them that will rest over their corresponding two 2...

Страница 23: ...his ember material as this could create an unsafe condition The pieces should be lightly placed so they don t block any of the burner ports DO NOT allow any of the embers to rest against the pilot ass...

Страница 24: ...as door Never operate the fireplace with the glass door removed When lighting the fireplace for the first time since the log set and embers have been installed replaced watch for ignition at ALL the b...

Страница 25: ...n the firebox If the side and front panels must be removed continue with steps 5 6 7 and 8 5 Lift the front panel located on the firebox bottom from one end and remove the panel at an angle through th...

Страница 26: ...replace thermocouple Air in gas line pilot dies while knob is depressed Bleed line Check gas line pressure Contact dealer Burners will not remain lit Problem with thermopile circuit Check gas line pre...

Страница 27: ...t 1 8 Tube with End Furrels 1 piece 30 043 11 Blank Orifice 73 50 343 Embers 50 491 On Off Remote Control Kit 50 559 Programmable Wall Mounted Remote Control 50 583 12 Dual Bulb Door Gasket 10 feet 50...

Страница 28: ...Parts Diagram Components SIENNA Components October 2004 28...

Страница 29: ...29 Parts Diagram Burner SIENNA Burner October 2004...

Страница 30: ...e Cottage Trim Kit Pewter 50 549 1A The Cottage Trim Kit Antique Copper 50 550 1A The Cottage Trim Kit Painted Black 50 694 2A Cape Cod Doors 50 1097 3A Unit Panel Keystone 50 1108 4A Cottage 50 1109...

Страница 31: ...31 Parts Diagram Options SIENNA Options October 2004...

Страница 32: ...Year Warranty Under this warranty Sherwood Industries Ltd covers all exterior surface finishes against defects in materials and workmanship for part repair or replacement and limited labour for the fi...

Страница 33: ...trees buildings roof tops wind hills mountains inadequate venting or ventilation excessive offsets negative air pressures or other influences caused by mechanical systems such as furnaces fans clothe...

Страница 34: ...stries Ltd is not liable for freight or labour on any stove replaced in field and is not liable for travel costs for service work In the event of in home repair work the customer will pay any in home...

Страница 35: ...____________________ MODEL ___________________________________ SERIAL NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy DIRECT VE...

Отзывы: