Secondary Installation

L

OG

 S

ET

 

AND

 E

MBER

 I

NSTALLATION

:

NOTE: The logs are fragile and should be handled gently.

The placement of the logs is not arbitrary. If they are positioned incorrectly, the flames can be “pinched” 

and will not burn correctly. The burner, and a few of the logs come with locator pins, notches and ledges, 

which make alignment easier.  Using the pictures provided, carefully set the logs in place (see Figures 31 

through 36). 

Figure 31: Empty firebox with grate and locator pins.

Figure 32.  First Stage Log Set Installation.

Figure 33.  Second Stage Log Set Installation.

Figure  32:  The 

left  log 

and 

the 

right  log 

both  have  two 

(2)  holes  in  them  that  will  rest 

over  their  corresponding  two 

(2)  locator  pins  pointed  out  in 

Figure 31.

Figure  33:  The  bottom  of  the 

left/center  log 

will  rest  over 

the  locator  pin  on  the  burner 

and  against  the  grate.  The  top 

half of the log must rest against 

the back log, see Figure 32. The 

center spot shown in Figure 32 

is a knot in the back log for the 

left/center  log  to  rest  against. 

Ensure  the  log  does  not  block 

any burn ports. 

Figure 31: The first log to 

be placed is the 

back log

It leans on the back of the 

firebox, push it back as far  

as you can.

22

Содержание Sienna BV

Страница 1: ...nstructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING If the informa...

Страница 2: ...o is unfamiliar with the stove to operate it To prevent injury if the pilot or pilot and burners have gone out on their own open the glass door and wait 5 minutes to air out before attempting to re li...

Страница 3: ...l Conversion 11 Initial Installation 13 Clearances to Combustibles 13 Minimum Fireplace Size 14 B Vent Model 14 Automatic Flue Gas Spill Switch B Vent Model Only 14 Direct Vent Model 15 Preparing Your...

Страница 4: ...GAS FIREPLACE HEATER SIENNA BV DV NG LPG TESTED TO ANSI Z21 88a 2003 CSA 2 33a 2003 VENTED GAS FIREPLACE HEATERS CAN CGA 2 17 M91 GAS FIRED APPLIANCES FOR HIGH ALTITUDES CSA P 4 1 02 TESTING METHOD F...

Страница 5: ...und 14 1 2 369 mm 14 3 8 365 mm From Back Sensor To Surround 17 1 16 434 mm 18 11 16 474 mm 33 x 46 840 x 1930 mm Surround with Trim From Flue To Trim 13 1 4 337 mm 13 1 16 333 mm From Back Sensor To...

Страница 6: ...rim 33 338 mm 20 5 8 523 mm 22 3 4 577 mm 22 11 16 576 mm With Trim 46 1 8 1171 mm Without Trim 46 1168 mm 21 533 mm 13 1 16 333 mm 1 3 8 36 mm 17 3 8 441 mm Shown B Vent with 33 x 46 84cm x 193 cm su...

Страница 7: ...will not allow the pilot burner to be relit until the thermocouple has cooled If the knob does not pop up when released stop and immediately call your service technician or gas supplier If the pilot d...

Страница 8: ...e blower off turn the knob COUNTER CLOCKWISE until it clicks off Figure 6 It is advisable not to operate the blower below 1 3 speed as it puts a strain on the windings of the blower and running the bl...

Страница 9: ...the logs carefully as they are very fragile Gently remove all the embers and rock wool and place on a paper towel Vacuum the bottom of the firebox thoroughly Carefully clean any dust off the logs and...

Страница 10: ...igure 8 Lift the bottom of the door up and remove from unit see Figure 9 CAUTION GLASS MAY SEPARATE FROM DOOR remove the complete gas and electrical tray assembly from the firebox ensuring that no wir...

Страница 11: ...ons is not followed exactly a fire explosion or production of carbon monoxide may result causing property damage personal injury or loss of life The qualified service agency is responsible for the pro...

Страница 12: ...d to pay special attention when installing the burner that the venturi adjustment rod is properly installed into the venturi adjustment piece welded to the burner venturi tube 9 Reconnect the main gas...

Страница 13: ...minimum height of 43 1092 mm from the bottom of unit If installed at floor level a minimum 16 406 mm non combustible material must be installed in front of the unit If installed on a 12 305 mm wide h...

Страница 14: ...AS SPILL SWITCH B VENT MODEL ONLY NOTE This heater must be properly connected to a venting system This heater is equipped with a vent safety shutoff system designed to protect against improper venting...

Страница 15: ...ue before installing the stove Failure to do so may result in fumes or dirt being blown into the room and may cause a fire leading to death or serious injury 1 Remove the unit from the box and remove...

Страница 16: ...State and local building codes and has been constructed of non combustible materials This appliance must not be connected to a chimney flue serving a separate solid fuel burning appliance Before start...

Страница 17: ...learance to a building opening or combustion air inlet of another appliance except with the approval of the authority having jurisdiction for the following reduced clearances 9 in 0 23 m Exception for...

Страница 18: ...three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong outlet DO NOT cut or remove the grounding prong from this plug C...

Страница 19: ...piping system at test pressures equal to or less than 1 2 psi 3 5 kPa The unit must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure te...

Страница 20: ...Ensure the tabs are under the brackets at the back and the holes at the front line up Secure into place with the two 2 T 20 screws at the front of the unit 4 Disconnect the two 2 blue wires at the ope...

Страница 21: ...r tighten the screw in each corner bracket in the side trims then tighten the top trim 2 Slide the two 2 attached trim pieces onto the surround panel 3 Attach the other side trim piece to the top trim...

Страница 22: ...re 32 First Stage Log Set Installation Figure 33 Second Stage Log Set Installation Figure 32 The left log and the right log both have two 2 holes in them that will rest over their corresponding two 2...

Страница 23: ...his ember material as this could create an unsafe condition The pieces should be lightly placed so they don t block any of the burner ports DO NOT allow any of the embers to rest against the pilot ass...

Страница 24: ...as door Never operate the fireplace with the glass door removed When lighting the fireplace for the first time since the log set and embers have been installed replaced watch for ignition at ALL the b...

Страница 25: ...n the firebox If the side and front panels must be removed continue with steps 5 6 7 and 8 5 Lift the front panel located on the firebox bottom from one end and remove the panel at an angle through th...

Страница 26: ...replace thermocouple Air in gas line pilot dies while knob is depressed Bleed line Check gas line pressure Contact dealer Burners will not remain lit Problem with thermopile circuit Check gas line pre...

Страница 27: ...t 1 8 Tube with End Furrels 1 piece 30 043 11 Blank Orifice 73 50 343 Embers 50 491 On Off Remote Control Kit 50 559 Programmable Wall Mounted Remote Control 50 583 12 Dual Bulb Door Gasket 10 feet 50...

Страница 28: ...Parts Diagram Components SIENNA Components October 2004 28...

Страница 29: ...29 Parts Diagram Burner SIENNA Burner October 2004...

Страница 30: ...e Cottage Trim Kit Pewter 50 549 1A The Cottage Trim Kit Antique Copper 50 550 1A The Cottage Trim Kit Painted Black 50 694 2A Cape Cod Doors 50 1097 3A Unit Panel Keystone 50 1108 4A Cottage 50 1109...

Страница 31: ...31 Parts Diagram Options SIENNA Options October 2004...

Страница 32: ...Year Warranty Under this warranty Sherwood Industries Ltd covers all exterior surface finishes against defects in materials and workmanship for part repair or replacement and limited labour for the fi...

Страница 33: ...trees buildings roof tops wind hills mountains inadequate venting or ventilation excessive offsets negative air pressures or other influences caused by mechanical systems such as furnaces fans clothe...

Страница 34: ...stries Ltd is not liable for freight or labour on any stove replaced in field and is not liable for travel costs for service work In the event of in home repair work the customer will pay any in home...

Страница 35: ...____________________ MODEL ___________________________________ SERIAL NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy DIRECT VE...

Отзывы: