FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” HEATER, 

PLEASE CAREFULLY READ THE FOLLOWING INFORMATION:

•  All ENVIRO gas-fired appliances must be installed 

in accordance with their instructions. Carefully read all 

the instructions in this manual first. Consult the building 

authority having jurisdiction to determine the need for 

a permit prior to commencing the installation.
•   

NOTE:

  Failure  to  follow  these  instructions  could 

cause  a  malfunction  of  the  fireplace,  which  could 

result in death, serious bodily injury, and/or property 

damage.
•  Failure to follow these instructions may also void 

your fire insurance and/or warranty.

GENERAL

•  Installation  and  repair  should  be  done  by  a 

qualified  service  person.  The  appliance  should  be 

inspected before the first use and, at least, annually 

by  a  qualified  service  person.  More  frequent 

cleaning  may  be  required  due  to  excessive  lint  from 

carpeting, bedding material, etc.  It is imperative the 

control  compartments,  burners  and  circulating  air 

passageways of the appliance be kept clean.
•  Due  to  high  temperatures,  the  appliance  should 

be  located  out  of  high  traffic  areas  and  away  from 

furniture and draperies.

Children  and  adults  should  be  alerted  to  the 

hazards  of  high  surface  temperatures  and 

should  stay  away  to  avoid  burn  or  clothing 

ignition.

•  Young  children  should  be  carefully  supervised 

when in the same room as the appliance.
•  Clothing or other flammable materials should not 

be placed on or near the appliance.

FOR YOUR SAFETY

•  Installation and service must be performed by a 

qualified installer, service agency or gas supplier.
•  This installation must conform to local codes or, in 

the absence of local codes, to the current CAN/CGA-

B149 installation code (Canada) or National Fuel Gas 

Code ANSI Z223.1.2 (USA)
•  To  prevent  injury,  do  not  allow  anyone  who  is 

unfamiliar with the stove to operate it.

 

To  prevent  injury,  if  the  pilot  or  pilot  and 

burners have gone out on their own, open the 

glass door and wait 5 minutes to air out before 

attempting to re-light the stove.

•  Always  keep  the  area  around  these  appliances 

clear  of  combustible  material,  gasoline  and  other 

flammable liquids and vapours.
•  These appliances should not be used as a drying 

rack for clothing or for hanging Christmas stockings/

decorations.
•  Due to the paint curing on the stove, a faint odor 

and  slight  smoking  will  likely  be  noticed  when  the 

stove is first used.  Open a window until the smoking 

stops.
Always connect this gas stove to a vent system and 

vent  to  the  outside  of  the  building  envelope.  Never 

vent to another room or inside the building. Make sure 

the specified vent pipe is used, properly sized and of 

adequate  height  to  provide  sufficient  draft.    Inspect 

the venting system annually for blockage and signs of 

deterioration.

WARNING: 

Failure to position the parts in accordance 

with the diagrams in this booklet, or failure to use only 

parts  specifically  approved  with  this  appliance,  may 

result in property damage or personal injury.

WARNING: 

Do  not  operate  with  the  glass  front 

removed,  cracked  or  broken.    Replacement  of  the 

glass should be done by a licensed or qualified service 

person.
•  Never  use  solid  fuels  such  as  wood,  paper, 

cardboard, coal, or any flammable liquids, etc., in this 

appliance.
•  Do not use this heater if any part has been under 

water. Immediately call a qualified service technician 

to inspect the heater and to replace any part of the 

control or gas control systems that have been under 

water.
•  Do not abuse the glass by striking it or slamming 

the door shut.
•  If the Sienna unit is pulled out of its installation, 

and  the  vent-air  intake  system  is  disconnected  for 

any  reason,  ensure  that  the  vent-air  intake  pipes 

are  reconnected  and  re-sealed  in  accordance  to  the 

instructions  noted  in 

I

NITIAL

  I

NSTALLATION

  -  V

ENTING

 

F

IREPLACE

 I

NSERTS

.

s

Safety Precautions

Содержание Sienna BV

Страница 1: ...nstructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING If the informa...

Страница 2: ...o is unfamiliar with the stove to operate it To prevent injury if the pilot or pilot and burners have gone out on their own open the glass door and wait 5 minutes to air out before attempting to re li...

Страница 3: ...l Conversion 11 Initial Installation 13 Clearances to Combustibles 13 Minimum Fireplace Size 14 B Vent Model 14 Automatic Flue Gas Spill Switch B Vent Model Only 14 Direct Vent Model 15 Preparing Your...

Страница 4: ...GAS FIREPLACE HEATER SIENNA BV DV NG LPG TESTED TO ANSI Z21 88a 2003 CSA 2 33a 2003 VENTED GAS FIREPLACE HEATERS CAN CGA 2 17 M91 GAS FIRED APPLIANCES FOR HIGH ALTITUDES CSA P 4 1 02 TESTING METHOD F...

Страница 5: ...und 14 1 2 369 mm 14 3 8 365 mm From Back Sensor To Surround 17 1 16 434 mm 18 11 16 474 mm 33 x 46 840 x 1930 mm Surround with Trim From Flue To Trim 13 1 4 337 mm 13 1 16 333 mm From Back Sensor To...

Страница 6: ...rim 33 338 mm 20 5 8 523 mm 22 3 4 577 mm 22 11 16 576 mm With Trim 46 1 8 1171 mm Without Trim 46 1168 mm 21 533 mm 13 1 16 333 mm 1 3 8 36 mm 17 3 8 441 mm Shown B Vent with 33 x 46 84cm x 193 cm su...

Страница 7: ...will not allow the pilot burner to be relit until the thermocouple has cooled If the knob does not pop up when released stop and immediately call your service technician or gas supplier If the pilot d...

Страница 8: ...e blower off turn the knob COUNTER CLOCKWISE until it clicks off Figure 6 It is advisable not to operate the blower below 1 3 speed as it puts a strain on the windings of the blower and running the bl...

Страница 9: ...the logs carefully as they are very fragile Gently remove all the embers and rock wool and place on a paper towel Vacuum the bottom of the firebox thoroughly Carefully clean any dust off the logs and...

Страница 10: ...igure 8 Lift the bottom of the door up and remove from unit see Figure 9 CAUTION GLASS MAY SEPARATE FROM DOOR remove the complete gas and electrical tray assembly from the firebox ensuring that no wir...

Страница 11: ...ons is not followed exactly a fire explosion or production of carbon monoxide may result causing property damage personal injury or loss of life The qualified service agency is responsible for the pro...

Страница 12: ...d to pay special attention when installing the burner that the venturi adjustment rod is properly installed into the venturi adjustment piece welded to the burner venturi tube 9 Reconnect the main gas...

Страница 13: ...minimum height of 43 1092 mm from the bottom of unit If installed at floor level a minimum 16 406 mm non combustible material must be installed in front of the unit If installed on a 12 305 mm wide h...

Страница 14: ...AS SPILL SWITCH B VENT MODEL ONLY NOTE This heater must be properly connected to a venting system This heater is equipped with a vent safety shutoff system designed to protect against improper venting...

Страница 15: ...ue before installing the stove Failure to do so may result in fumes or dirt being blown into the room and may cause a fire leading to death or serious injury 1 Remove the unit from the box and remove...

Страница 16: ...State and local building codes and has been constructed of non combustible materials This appliance must not be connected to a chimney flue serving a separate solid fuel burning appliance Before start...

Страница 17: ...learance to a building opening or combustion air inlet of another appliance except with the approval of the authority having jurisdiction for the following reduced clearances 9 in 0 23 m Exception for...

Страница 18: ...three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong outlet DO NOT cut or remove the grounding prong from this plug C...

Страница 19: ...piping system at test pressures equal to or less than 1 2 psi 3 5 kPa The unit must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure te...

Страница 20: ...Ensure the tabs are under the brackets at the back and the holes at the front line up Secure into place with the two 2 T 20 screws at the front of the unit 4 Disconnect the two 2 blue wires at the ope...

Страница 21: ...r tighten the screw in each corner bracket in the side trims then tighten the top trim 2 Slide the two 2 attached trim pieces onto the surround panel 3 Attach the other side trim piece to the top trim...

Страница 22: ...re 32 First Stage Log Set Installation Figure 33 Second Stage Log Set Installation Figure 32 The left log and the right log both have two 2 holes in them that will rest over their corresponding two 2...

Страница 23: ...his ember material as this could create an unsafe condition The pieces should be lightly placed so they don t block any of the burner ports DO NOT allow any of the embers to rest against the pilot ass...

Страница 24: ...as door Never operate the fireplace with the glass door removed When lighting the fireplace for the first time since the log set and embers have been installed replaced watch for ignition at ALL the b...

Страница 25: ...n the firebox If the side and front panels must be removed continue with steps 5 6 7 and 8 5 Lift the front panel located on the firebox bottom from one end and remove the panel at an angle through th...

Страница 26: ...replace thermocouple Air in gas line pilot dies while knob is depressed Bleed line Check gas line pressure Contact dealer Burners will not remain lit Problem with thermopile circuit Check gas line pre...

Страница 27: ...t 1 8 Tube with End Furrels 1 piece 30 043 11 Blank Orifice 73 50 343 Embers 50 491 On Off Remote Control Kit 50 559 Programmable Wall Mounted Remote Control 50 583 12 Dual Bulb Door Gasket 10 feet 50...

Страница 28: ...Parts Diagram Components SIENNA Components October 2004 28...

Страница 29: ...29 Parts Diagram Burner SIENNA Burner October 2004...

Страница 30: ...e Cottage Trim Kit Pewter 50 549 1A The Cottage Trim Kit Antique Copper 50 550 1A The Cottage Trim Kit Painted Black 50 694 2A Cape Cod Doors 50 1097 3A Unit Panel Keystone 50 1108 4A Cottage 50 1109...

Страница 31: ...31 Parts Diagram Options SIENNA Options October 2004...

Страница 32: ...Year Warranty Under this warranty Sherwood Industries Ltd covers all exterior surface finishes against defects in materials and workmanship for part repair or replacement and limited labour for the fi...

Страница 33: ...trees buildings roof tops wind hills mountains inadequate venting or ventilation excessive offsets negative air pressures or other influences caused by mechanical systems such as furnaces fans clothe...

Страница 34: ...stries Ltd is not liable for freight or labour on any stove replaced in field and is not liable for travel costs for service work In the event of in home repair work the customer will pay any in home...

Страница 35: ...____________________ MODEL ___________________________________ SERIAL NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy DIRECT VE...

Отзывы: