49
Initial Installation
QUALIFIED INSTALLERS ONLY
R
eLocating
g
as
c
onnection
1.
Disconnect the two (2) T20 screws securing the ball valve
plate (see Figure 88).
2.
Disconnect the four (4) T20 screws securing the ball
valve.
3.
Loosen off ball valve jam screw and reattach ball valve
cradle onto the relocation plate (included in the manual
bag, refer to Figure 90 for proper geometry and orien-
tation). Re-tighten jam screw and ensure ball valve is
secure.
4.
Use appropriate thread sealant and connect the 1/2”
elbow fitting (included in the manual bag). Orientate the
fitting downward.
5.
Work the flex line and get the gas connection assembly
into position as shown in Figure 92. Attach the assembly
to the firebox using two (2) 5/16” hex head bolts from
below.
Figure 88:
Gas Plate Disconnection
Figure 89:
Gas Plate Removal
Figure 90: Gas Adapter Connection
Figure 91: 1/2” Elbow Fitting Connection
Figure 92:
Gas Connection Re-installation