a
iR
s
hutteR
:
Behind the valve access door is the air shutter adjustment lever on the right hand side of the venturi box
(see Figure 3) above the control panel. The air shutter allows the amount of air coming into the fireplace
to be adjusted in order to accommodate different climates and venting arrangements. Start the pilot and
then the burner. Make sure the pilot flame is burning normally and none of the burner ports are plugged.
Let the fireplace burn for roughly fifteen minutes and then examine the flames, compare the flames to
Figure 47.
The ideal flame will be blue at the base and light orange above. The flames should be of medium height.
If the flames look like this, no venturi adjustment is needed. If the flames are fairly short and mostly blue,
the fireplace is getting too much air. Therefore, the air shutter should be closed (pulled out) slightly until
the correct flames are achieved. Flames that are very orange, with tall, dark, stringy tips, are not getting
enough air. Open (push in) the venturi until the flames clean up. If the venturi is opened, or closed all the
way, and the correct flames cannot be attained, turn off the gas and contact the dealer.
Warning:
Incorrect shutter adjustment may lead to improper combustion, which is a safety hazard.
Contact the dealer if there is any concern about the venturi adjustment.
Figure 3. Air shutter adjustment lever.
8
Less Air
More Air
Air Shutter Adjustment
Valve
Access
Door
*Parts
Removed for
Clarity*
Operating Instructions
n
oRmaL
s
ounDs
D
uRing
o
peRation
:
Table 1: Normal Sounds
Component
Sound & Reason
S30I
Creaking when heating up or cooling down.
Burner
Light pop or poof when turned off; this is more common with LP units.
Temperature Sensor
Clinking when it senses to turn the blower on or off.
Pilot Flame
Quiet whisper while the pilot flame in on.
Blower / Fan
Air movement that increase and decreases with the speed of the blower. The
blower is pushing the heat from the fireplace into the room.
Gas Control Valve
Dull click when turning on or off, this is the valve opening and closing.
R
emote
c
ontRoL
o
peRations
:
The Proflame 2 GTMFL is a modular remote control system that directs the functions of the S30I.
The Proflame 2 GTMFL is configured to control the on/off main burner operation, its flame levels and
provides on/off and Smart thermostatic control of the appliance. The system controls a remotely actuated
120V/60Hz power outlet, and fan speed through six (6) levels.