Rating Label
Certified for use in Canada & USA /
Certifié pour installation au Canada et aux
Etats-Unis.
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
LISTED GAS FIREPLACE HEATER /
LISTE DES
APP
AREILS
AU GAZ VENTILÉS
Serial No. / No. De Serié:
DATE OF MANUFACTURE /
DATE DE FABRICATION:
J F M A M J J A S O N D 2015 2016
2017 2018 2019
C-14558
MANUFACTURED BY /
FABRIQUE PAR
: SHERWOOD INDUSTRIES LTD. 6782 OLDFIELD ROAD, SAANICHTON, BC CANADA
MADE IN CANADA /
FABRIQUE AU CANADA
Model
/
Modèle:
S30 Nova Log Burner
S30I IPI Log Burner
4001609
Fuel
/
Carburant:
NA
T
(Gaz naturel)
LPG (Propane)
INPUT
(E
NT
RÉ
E
À) at 0-4500 feet/pied (0-1372 m):
NA
T (Gaz naturel)
LPG (Propane)
MAX: 20,000 Btu/hr (5.86 kWh) MIN: 13,600 Btu/hr (3.98 kWh)
MAX: 18,500 Btu/hr (5.42 kWh) MIN: 14,500 Btu/hr (4.25 kWh)
MANIFOLD PRESSURE (P
RE
SS
IO
N
DE
S
CO
ND
UI
TS
):
ORIFICE SIZE (
GROSSEUR DE L'ORIFICE
):
# 46
1.2 mm
GAS SUPPL
Y PRESSURE
(P
RE
SS
IO
N
D'
AP
PR
O
VI
SI
O
NN
EM
EN
T
DU
G
AZ
):
MAX: 3.5 inch W
.C. (0.87 kPa)
MIN: 1.5 inch W
.C. (0.37 kPa)
MAX: 10 inch W
.C. (2.49 kPa)
MIN: 6.4 inch W
.C. (1.59 kPa)
MAX: 7 inch W
.C. (1.74 kPa)
MIN: 4.5 inch W
.C. (1.12 kPa)
MAX: 1
1 inch W
.C. (2.74 kPa)
MIN: 10.4 inch W
.C. (2.59 kPa)
DV
CAUTION/A
TTENTION
:
Hot while in operation. Do not touch. Severe burns may result. Keep children, clothing, furniture, gasoline and other liquids h
aving flammable vapours away / Chaud pendant
le fonctionnement. Ne touchez pas. Des brûlures gr
aves peuvent en résulter
. Gardez les enfants, les vêtements, meubles, essence et autres liquides ayant des vapeurs inflammables loin.
CONFORMS
TO / Conforme :
ANSI Z21.88-2014, CERITIFIED
TO /
Agréé : CSA
2.33-2014
VENTED GAS FIREPLACE HEA
TERS /
APP
AREIL
DE CHAUFF
AGE À
ÉV
ACUA
TION DIRECTE, CAN/CGA
2.17-M91 (R2014) GAS FIRED
APPLIANCES FOR
HIGH
AL
TITUDES /
APP
AREIL
AU GAZ POUR HAUTES
AL
TITUDES.
This appliance
equipped o
nly for altitudes 0-2000 feet (0-610 m). In Canada 0-4500 feet (1370 m) / Cet
appareil pe
ut être utilisé à des altitudes comprises entre 0 et 610 mètres (0 et 2000 pieds)
seulement. En Canada 0 et 1370 mètres (0-4500 pieds). For use only with barriers Part Numbers 50-3070. Follow installation instructions / Utiliser uniquement avec l’écran no 50-3070. Suivre les instructions d’installation.
CAUTION/A
TTENTION
:
Do not operate the appliance with glass removed, cracked or broken. Replacement of the panel should be done by a licensed of qu
alified service person /
Ne pas faire
fonctionner l'appareil avec un verre enlevée, fissurée ou
cassée. Remplacement du panneau doit être ef
fectuée par une personne de service certifié ou qualifié.
CLEARANCES TO COMBUSTIBLES / CLAIRANCE DES COMBUSTIBLES:
All Models Minimum Alcove / tous les modèles alcôve minimum:
From Sides / partir de côtés: 10.75” (273mm) From Back / de l'arrière: 4” (101.6mm) From Top / de haut: 12.0” (304.8mm) Floor / étage: N/A
VENT PIPE CLEARANCES
: See manufacturer’s listing, label and installation instructions. May be installed in a bedroom or
bedsitting room (IN CANADA a listed wall thermostat). The total vent length must be between 7in (17.7cm) and 44ft (13.4m).
This appliance must be properly connected to a venting system in accordance with the manufacturer’s installation
instructions. If any of the venting is disassembled after installation, it must be properly resealed according to the instructi
ons
in the owners manual. This appliance must be installed in accordance with local codes, if any; if none, follow the National
Fuel Gas Code, ANSI Z223.1/NFPA 54, or Natural Gas and Propane Installation Codes, CSA B149.1. This vented gas
fireplace heater is not for use with air filters. FOR USE WITH GLASS DOORS CERTIFIED WITH THE APPLIANCE ONLY.
This appliance is only for use with the type of fuel indicated on this rating label. See owner's manual for details. This
appliance is not convertible for use with other gases, unless a certified kit is used. Keep burner and control compartment
clean. See installation and operating instructions accompanying appliance.
.
WARNING: Failure to install this appliance per the manufacturer’s instructions or failure to use only parts specifically appro
ved with this appliance may result in property damage or personal injury. WARNING: Do not operate the
appliance until all sections have been assembled and installed
in accordance with the manufacturers instructions. This model c
an be vented with approved 4” x 6 ⅝“ galvanized or stainless st
eel solid vent.
CL
AIR
AN
CE
D
ES
T
UY
AU
X D
E V
EN
TIL
AT
IO
N: C
on
su
lte
z l
es
lis
te
s, l
es
é
tiq
ue
tte
s e
t l
es
in
str
uc
tio
ns
d'installation du manufacturier
. Ces appareils peuvent être installés dans une chambre à coucher (au CANADA
avec thermostat mural). La longueur totale du conduit doit être comprise entre 7 pouces (17.7cm) et 44 pieds (13.4m). Pour une
installation dans un âtre ventilé et composé de matériaux non
combustibles. Si aucun code n'existes, utilisez les codes ci-inclus : CAN/CGA
B149 au Canada ou
ANSI Z223.1 / NFP
A 54 aux États-Unis. Cet appareil au gaz ne doit pas être utilisé avec des filtres à air
. POUR UTILISA
TION UNIQUEMENT
A
VEC LES POR
TES EN VERRE CER
TIFIÉES
AVEC L
’APP
AREIL.
Ve
nte
d G
as
Fir
ep
lac
e H
ea
ter
- N
ot f
or
U
se
w
ith
So
lid
Fu
el
Foyer au gaz à évacuation. Ne pas utiliser avec du combustible solide.
W
ARNING/A
VERTISSEMENT
: Fire or explosion hazard. Can cause property damage, severe injury
,
or death.
This is a fast-acting thermocouple. Replace it only w
ith another fast-acting thermocouple specified
by the manufacturer
. Refer to the manual for the part number
/ Risque d’incendie ou d’explosion. Peut
entraîner des dommages matériels, des blessures graves ou
la mort. Ceci est un thermocouple rapide. Peut
être remplacé uniquement par un autre thermocouple rapide s
pécifié par le fabricant de l’appareil. V
euillez
consulter à la notice pour le numéro de pièce
Keep burner and control compartment clean. See installation and operating instructions accompanying appliance / S’assurer que l
e brûleur et le compartiment des commandes sont propres. V
oir les instructions d’installation et d’utilisation qui accompagnent l’appareil.
VITRE CHA
UDE –
RISQUE
DE BRÛL
URE
S.
NE T
OUCHE
Z P
AS
UN
E
VITRE N
ON REFR
OIDIE.
NE LAISSE
Z J
AMAIS
UN
ENF
AN
T T
OUCHER LA VITRE.
de
brûlur
e en c
as de c
on
tact acciden
te
l a
ve
c la vitr
e
et des per
sonne
s à risques.
HO
T GLASS
WILL
CA
USE BURN
S
DO NO
T T
OUCH
GLASS
UN
TIL C
OOLED
.
NEVER
ALL
OW CHILDREN
TO T
OUCH GLASS.
A barrie
r designe
d t
o r
educe
the
risk
of burns fr
om the
hot vie
wing glass is pr
ovided with this appliance and shall
individuals.
Les appareils de chauf
fage à évacuation direct ne doivent pas être utilisés avec des carburants solides. Utilisez seulement des
portes vitrées approuvées pour cet appareil.
AVER
TISSEMENT
: Si vous installez cet appareil selon les instructions du fabricant
ou de l'échec d'utiliser seulement les pièces spécifiquement approuvé avec cet appareil peut entraîner des dommages matériels
ou corporels.Cet appareil doit être utilisé seulement avec le type de carburant mentionné et requis sur l'étiquette de classifi
cation
de cet appareil. Consultez le guide du propriétaire pour plus de détails. Cet appareil ne peut être converti pour utilisation a
vec
d'autres gaz que celui mentionné sur l'étiquette de classification, sauf si une trousse de conversion certifiée est utilisée.
AVER
TISSEMENT
: Ne faites pas fonctionner l'appareil tant que toutes les pièces et les sections ne soient pas assemblées et/ou
installées en concordance avec les instructions du manufacturie
r. Ce modèle peut être évacué avec approuvé 4"x 6 ⅝" partie
galvanisé ou en acier inoxydable solide évent.
ELECTRICAL
REQUIREMENTS / BESOINS ÉLECTRIQUES:
115 V
AC, 60 Hz, 0.9
Amp (fan type vented circulator
,
Sherwood Industries Ltd Part #50-2493 / V
entilateur de type cage d'écureuil, Les Industries Sherwood Ltée. Pièce #50-2493
S
AMPLE