Specifications
A
UTOMATIC
F
LUE
G
AS
S
PILL
S
WITCH
:
NOTE:
THIS HEATER MUST BE PROPERLY CONNECTED TO A VENTING SYSTEM. THIS HEATER IS EQUIPPED WITH
A VENT SAFETY SHUTOFF SYSTEM DESIGNED TO PROTECT AGAINST IMPROPER VENTING OF COMBUSTION
PRODUCTS. THIS SAFETY SWITCH IS LOCATED ON THE REAR OF THE APPLIANCE CLOSE TO
THE DRAFT HOOD
RELIEF OPENING. IF THE SWITCH TRIPS MORE THAN ONCE, THE VENTING SHOULD BE INSPECTED BY A
QUALIFIED SERVICE TECHNICIAN FOR POSSIBLE BLOCKAGE OR SEVERE DOWN DRAFT CONDITIONS.
BV Only:
The draft hood must be in the same pressure zone as the air inlet. To inspect draft from the front of
the unit, locate the 1/4” tube between the louvers and check for a draft using smoke. A vacuum or suction into
the tube will indicate proper drafting.
This model can be vented with 4” aluminum or stainless steel flex vent and/or certified Type B Gas Vent. The flue
collar of the appliance will fit inside of a standard 4” vent and may be fastened directly to the vent, check periodically
that the vent is unrestricted and an adequate draft is present when the unit is in operation.
CHECK
DRAFT WITH
A MATCH OR
SMOKE IN
1/4” TUBE
LOCATED
HERE
B V
ENT
M
ODEL
:
WARNING
:
This appliance has been designed to operate by drawing combustion air and dilution air from the
room. It is also designed to draw room air for proper heat circulation from the sides of the unit. Blocking or
modifying the louvers in any way can create hazardous situations, either through poor venting or by overheating. It
is important that this unit has sufficient air circulation for proper venting and combustion. Provisions must be made
for the supply of adequate combustion and ventilation air. These openings must not be blocked. The appliance must
not be connected to a chimney flue servicing a separate solid fuel burning appliance.
D
IRECT
V
ENT
M
ODEL
:
WARNING: This appliance has been designed to draw room air for proper heat circulation from the
sides of the unit. Blocking or modifying the louvers in any way can create hazardous situations.
This model is vented with TWO (2) 3” aluminum or stainless steel flex vent leading into a co-linear to co-axial vent
adaptor and using a Simpson Dura Vent vertical termination cap. The flue collars of this model will fit inside of
standard 3” vent and may be fastened directly to the vent. The Exhaust vent is in the center of the flue connector.
The Air Intake is on the left side of the vent collar plate (this outlet is not in the center it is off to one side of the
vent collar plate.)
Check periodically that the vents are unrestricted. Also ensure that all direct vent pipes have been properly sealed
and installed after routine inspection or cleaning. The air intake and exhaust pipes must be installed in the correct
locations on the removable draft hood connector.
WARNING:
Operation of this heater when not connected to a properly installed and maintained venting
system can result in carbon monoxide (CO) poisoning and possible death.