Codes And Approvals

DIRECT VENT: 

This type is identified by the prefix 

DV

.  This appliance draws all of its’ air for  

 

combustion from outside the dwelling, through a specially designed vent pipe system.

** DV ONLY**     Certified for installation from 0-4500 ft  (1372 m)

VENTED 

Type is identified by the suffix 

BV.

 This appliance draws in room air for combusion and 

vent dilution air.

•  These appliances have been tested by INTERTEK TESTING SERVICES (

Warnock Hersey

and  found  to  comply  with  the  established  standards  VENTED  GAS  FIREPLACE  HEATER  in 

CANADA and the USA as follows:

VENTED GAS FIREPLACE HEATER (FOCUS BV / DV) (NG/LPG)

TESTED TO: ANSI Z21.88.1998   CSA 2.33.M98 VENTED GAS FIREPLACE HEATER

CSA 2.17 GAS FIRED APPLIANCES FOR HIGH ALTITUDES

**BV ONLY**        

Certified for installation from 0-2000 ft (610 m)

FOR INSTALLATIONS ABOVE 2000 ft (610 m)

In Canada, there appliances are certified for altitudes of 0-2000 ft (610 m) and must be derated by 10% 

for installations at elevations between 2000 ft (610 m) and 4500 ft (1372 m).

NATURAL GAS                                                 PROPANE GAS

INPUT

; 26,700 Btu/h (7.76 kW h)                    

INPUT

; 26,700 Btu/h (7.76 kW h)  

  

                     

ORIFICE SIZE #39 DMS                                  ORIFICE SIZE # 53 DMS

  •  In  the  USA,  these  appliance  are  certified  for  elevations  up  to  2,000  feet  (810  m).    For 

elevations above 2,000 feet (810 m), input should be reduced 4% for each 1,000 feet (405 m) 

above sea level.

This ENVIRO FOCUS Fireplace: 

• Has been certified for use with either natural or propane gas. (See rating label.)

• Is not for use with solid fuels.

• Is approved for bedroom or bed sitting room. (Canada; must install an approved wall thermostat.

• Must be installed on a non combustible surface. 

• Must be installed in accordance with local codes. If none exist, use current installation code CAN/CGA 

B149 in Canada or ANSI Z223.1/NFPA 54 in the USA.

• Must be properly connected to a venting system and not connected to a chimney flue serving a separate 

solid-fuel burning appliance.

•Must have inner flat unit glass installed before bay window can be installed.

WARNING: For installation only in a solid fuel burning fireplace with a working 

flue and constructed of non-combustible material using a chimney liner kit. 

 

4

Содержание FOCUS EG31-118

Страница 1: ...s instructions If you cannot reach your gas supplier call the fire department WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage...

Страница 2: ...o the current CAN CGA B149 installation code Canada or National Fuel Gas Code ANSI Z223 1 2 USA To prevent injury do not allow anyone who is unfamiliar with the stove to operate it To prevent injury i...

Страница 3: ...ings 10 Maintaining Face and Surround Finishes 10 Initial Installation 11 Venting Fireplace Inserts 11 Preparing Your Focus For Installation 12 Fuel Conversion 13 Electrical Requirements 14 Installing...

Страница 4: ...ns between 2000 ft 610 m and 4500 ft 1372 m NATURAL GAS PROPANE GAS INPUT 26 700 Btu h 7 76 kW h INPUT 26 700 Btu h 7 76 kW h ORIFICE SIZE 39 DMS ORIFICE SIZE 53 DMS In the USA these appliance are cer...

Страница 5: ...trol panel and is attached to a rectangular metal sheet that is chained to the fireplace Mantle pillar to glass door 9 22 8 cm From floor to 8 wide mantle 38 96 5 cm Minimum non combustible surface in...

Страница 6: ...ifying the louvers in any way can create hazardous situations either through poor venting or by overheating It is important that this unit has sufficient air circulation for proper venting and combust...

Страница 7: ...nit NOTE Make sure the pilot light completely engulfs the thermocouple and that the burner lights completely Warning The gas valve has a lockout device that prevents the pilot burner from being re lit...

Страница 8: ...r door as the unit will start to smoke and can irritate some people After the unit has gone through the first burn turn the unit off including the pilot let the unit get cold then remove the glass doo...

Страница 9: ...lm on the glass This is a temporary problem It is therefore recommended that the glass be cleaned initially after the first two weeks of use Depending upon the amount of use cleaning should be require...

Страница 10: ...g and light pilot with door open ADJUSTING VENTURI AIR SETTINGS When a plated surround or face is received it should be unpacked unwrapped carefully to avoid getting anything on the surface of the fin...

Страница 11: ...d position must be installed The ENVIRO FOCUS may be installed and vented into any solid fuel fireplace that has been installed in accordance with the National Provincial State and local building code...

Страница 12: ...quirements section 10 Place the assembled surround panel around the stove align the slots Push back then down to engage the surround panel hooks with the slots in the fireplace Install the decorative...

Страница 13: ...the conversion kit STEP 6 Install the new pilot injector supplied with this conversion kit Simply screw the new injector inside the pilot hood and reinstall pilot hood by placing hood on the assembly...

Страница 14: ...tray Slide tray to the left and lift out Remove brick panels see Removing and Installing Brick Panels 2 Remove the surround panel by lifting straight up and then pull out to free from the body of the...

Страница 15: ...jury or property damage Drafthood Cover Plate Chimney Connector Air Channel Cover Plate x2 1 Remove the chimney connector 300 spill switch two 2 B vent air channels and B vent draft diverter plate 2 I...

Страница 16: ...3 45kPa or the valve will be damaged The unit must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping s...

Страница 17: ...e Place the rear log on the two back placement pins Install the left front log on the left placement pin with the narrow end of the log resting on the rectangular rest area Install the right front log...

Страница 18: ...orts If a long delay is noted wait for the appliance to cool down Open the front door of the appliance Carefully reposition the embers making sure that the burner ports are not plugged or blocked Open...

Страница 19: ...ntact dealer Burners will not remain lit Problem with thermopile circuit Check gas line pressure Check for flame impingement in thermopile If low see Pilot will not remain lit Check thermopile for min...

Страница 20: ...EG31 072 Log Set With Embers Pre S N 12663 EG31 074 Brick Liner Ceramic Part Part Description EG31 075 Burner Switch Bracket EG31 089 Window Channel Tape EG31 090 1 Piece Glass With Tape EG31 091 Stee...

Страница 21: ...402 Cast front only no surround glass valve door or clip on Painted 50 403 Cast front only no surround glass valve door or clip on Antique White 50 404 Cast front only no surround glass valve door or...

Страница 22: ...r EC 069 Leveling Bracket Piezo Igniter EC 023 Burner Switch EC 026 Fan Controller EC 039 Painted Door EG31 092 Glass with Tape EG31 090 Rating Label Main Orifice EC 022 Ceramic Brick Liner EG31 074 B...

Страница 23: ...L M O U N T I N G B R A C K E T S Q U A R E F L U S H F A S C I A P A I N T E D E G 3 1 1 1 2 G O L D E G 3 1 1 1 2 N I C K E L 5 0 4 8 7 A R C H E D F L U S H F A S C I A P A I N T E D E G 3 1 1 0 6...

Страница 24: ...Pearl Grey Cast Iron Bay Face and Surround Wedgwood Blue Cast Iron Bay Face and Surround Westport Green 50 811 Cast Iron Bay Face and Surround Antique Chestnut Cast Iron Sides Cast Iron Bay Window Cas...

Страница 25: ...correct conditions Sherwood Industries Ltd offers a two year warranty on all the electrical components and gas components against manufacturing defects Paint is also covered against flaking This offer...

Страница 26: ...____________________________ MODEL ___________________________________ SERIAL NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy N...

Отзывы: