Enviro FOCUS EG31-118 Скачать руководство пользователя страница 20

20

Parts List

Part #

Part Description

30-030

Extension Knob (Pilot)

30-031

Extension Knob (HI-LO)

30-034

Relief Door & Gasket

50-343

Blank Orifice #73

50-506

Rear Log

50-507

Left Front Log

50-508

Right Front Log

50-509

Big Log Twig

50-510

Small Log Twig

50-520

300°F (149°C) Temperature Sensor N/C 

Spill Switch

50-528

BV Flue Collar Gasket

50-529

DV Flue Collar Gasket

50-531

Steel Bay Cover - Painted

50-588

Log Set & Embers (Post S/N 12663)

50-634

Dual Bulb Door Gasket (10 feet)

50-897

Pan Burner

EC-001

120°F (49°C) Ceramic Fan Temperature 

Sensor

EC-006

S.I.T. Nova Valve NG (50% Turn Down)

EC-007

S.I.T. Nova Valve LP (50% Turn Down)

EC-009

Thermocouple (Post 10/00)

EC-011

Spark Electrode with Ignitor Cable (Post 

10/00)

EC-012

Thermopile

EC-015

Fully Assembled Pilot NG

EC-016

Fully Assembled Pilot LP

EC-021

Pilot Gasket

EC-023

S.I.T. Piezo Ignitor

EC-026

FPI Burner Switch 

EC-039

FPI Fan Controller - 115V

EC-041

FPI Fan Controller Knob

EC-042

Domestic Power Cord - 115V

EC-044

Heyco Strain Relief

EC-046

Embers (Coal & Wool)

EC-069

Convection Blower - 115V

EG31-052 Burner Control Assembly NG
EG31-053 Burner Control Assembly LP
EG31-062 18” Flex Line With 3⁄8 Elbow
EG31-072 Log Set With Embers (Pre S/N 12663)
EG31-074 Brick Liner - Ceramic

Part #

Part Description

EG31-075 Burner Switch Bracket
EG31-089 Window Channel Tape
EG31-090 1 Piece Glass With Tape
EG31-091 Steel Bay 3 Pieces Glass Set with Tape
EG31-092 Door Only - Painted
EG31-099 Venturi
EG31-118 Owner’s Manual
EG31-124 3⁄8” NTP Male 3⁄8 Comp. 90° Elbow
EG31-125 1⁄4” NTP Female 3⁄8 Comp. 90° Elbow
EG31-200 LP to NG Conversion Kit
EG31-202 NG to LP Conversion Kit
EG31-205 Conversion Kit BV to DV
EG31-206 Conversion Kit DV to BV
50-092

Bay Face - Polished Nickel

50-111

Regular Surround Panel - Black Trim

50-112

Oversized Surround Panel - Black Trim

50-123

Trim Only - Black

50-135

Trim Only - Nickel

50-141

Steel Bay Face With Glass -  Painted 

Black

50-142

Steel Bay Cover - Gold

50-143

Steel Bay Cover - Polished Nickel

50-487

Square Face - Nickel

50-505

Louvre Set Top & Bottom -  Painted 

Black

50-595

Cape Cod Front

50-597

Cottage Trim Kit - Gold

50-598

Cottage Trim Kit - Pewter

50-599

Cottage Trim Kit - Antique Copper

50-610

Ceramic Brick Liner (Post S/N 12663)

50-695

Cottage Face - No Trim

50-696

Cottage Trim Kit - Painted Black

EG31-103 Standard Surround Panel Trim - Brass
EG31-106 Arched Face -  Painted Black
EG31-107 Oversized Surround Panel Trim - Nickel
EG31-108 Arched Face - Gold
EG31-110 Square Face - Painted Black
EG31-112 Square Face - Gold
EG31-113 Arched Face - Nickel

Содержание FOCUS EG31-118

Страница 1: ...s instructions If you cannot reach your gas supplier call the fire department WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage...

Страница 2: ...o the current CAN CGA B149 installation code Canada or National Fuel Gas Code ANSI Z223 1 2 USA To prevent injury do not allow anyone who is unfamiliar with the stove to operate it To prevent injury i...

Страница 3: ...ings 10 Maintaining Face and Surround Finishes 10 Initial Installation 11 Venting Fireplace Inserts 11 Preparing Your Focus For Installation 12 Fuel Conversion 13 Electrical Requirements 14 Installing...

Страница 4: ...ns between 2000 ft 610 m and 4500 ft 1372 m NATURAL GAS PROPANE GAS INPUT 26 700 Btu h 7 76 kW h INPUT 26 700 Btu h 7 76 kW h ORIFICE SIZE 39 DMS ORIFICE SIZE 53 DMS In the USA these appliance are cer...

Страница 5: ...trol panel and is attached to a rectangular metal sheet that is chained to the fireplace Mantle pillar to glass door 9 22 8 cm From floor to 8 wide mantle 38 96 5 cm Minimum non combustible surface in...

Страница 6: ...ifying the louvers in any way can create hazardous situations either through poor venting or by overheating It is important that this unit has sufficient air circulation for proper venting and combust...

Страница 7: ...nit NOTE Make sure the pilot light completely engulfs the thermocouple and that the burner lights completely Warning The gas valve has a lockout device that prevents the pilot burner from being re lit...

Страница 8: ...r door as the unit will start to smoke and can irritate some people After the unit has gone through the first burn turn the unit off including the pilot let the unit get cold then remove the glass doo...

Страница 9: ...lm on the glass This is a temporary problem It is therefore recommended that the glass be cleaned initially after the first two weeks of use Depending upon the amount of use cleaning should be require...

Страница 10: ...g and light pilot with door open ADJUSTING VENTURI AIR SETTINGS When a plated surround or face is received it should be unpacked unwrapped carefully to avoid getting anything on the surface of the fin...

Страница 11: ...d position must be installed The ENVIRO FOCUS may be installed and vented into any solid fuel fireplace that has been installed in accordance with the National Provincial State and local building code...

Страница 12: ...quirements section 10 Place the assembled surround panel around the stove align the slots Push back then down to engage the surround panel hooks with the slots in the fireplace Install the decorative...

Страница 13: ...the conversion kit STEP 6 Install the new pilot injector supplied with this conversion kit Simply screw the new injector inside the pilot hood and reinstall pilot hood by placing hood on the assembly...

Страница 14: ...tray Slide tray to the left and lift out Remove brick panels see Removing and Installing Brick Panels 2 Remove the surround panel by lifting straight up and then pull out to free from the body of the...

Страница 15: ...jury or property damage Drafthood Cover Plate Chimney Connector Air Channel Cover Plate x2 1 Remove the chimney connector 300 spill switch two 2 B vent air channels and B vent draft diverter plate 2 I...

Страница 16: ...3 45kPa or the valve will be damaged The unit must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping s...

Страница 17: ...e Place the rear log on the two back placement pins Install the left front log on the left placement pin with the narrow end of the log resting on the rectangular rest area Install the right front log...

Страница 18: ...orts If a long delay is noted wait for the appliance to cool down Open the front door of the appliance Carefully reposition the embers making sure that the burner ports are not plugged or blocked Open...

Страница 19: ...ntact dealer Burners will not remain lit Problem with thermopile circuit Check gas line pressure Check for flame impingement in thermopile If low see Pilot will not remain lit Check thermopile for min...

Страница 20: ...EG31 072 Log Set With Embers Pre S N 12663 EG31 074 Brick Liner Ceramic Part Part Description EG31 075 Burner Switch Bracket EG31 089 Window Channel Tape EG31 090 1 Piece Glass With Tape EG31 091 Stee...

Страница 21: ...402 Cast front only no surround glass valve door or clip on Painted 50 403 Cast front only no surround glass valve door or clip on Antique White 50 404 Cast front only no surround glass valve door or...

Страница 22: ...r EC 069 Leveling Bracket Piezo Igniter EC 023 Burner Switch EC 026 Fan Controller EC 039 Painted Door EG31 092 Glass with Tape EG31 090 Rating Label Main Orifice EC 022 Ceramic Brick Liner EG31 074 B...

Страница 23: ...L M O U N T I N G B R A C K E T S Q U A R E F L U S H F A S C I A P A I N T E D E G 3 1 1 1 2 G O L D E G 3 1 1 1 2 N I C K E L 5 0 4 8 7 A R C H E D F L U S H F A S C I A P A I N T E D E G 3 1 1 0 6...

Страница 24: ...Pearl Grey Cast Iron Bay Face and Surround Wedgwood Blue Cast Iron Bay Face and Surround Westport Green 50 811 Cast Iron Bay Face and Surround Antique Chestnut Cast Iron Sides Cast Iron Bay Window Cas...

Страница 25: ...correct conditions Sherwood Industries Ltd offers a two year warranty on all the electrical components and gas components against manufacturing defects Paint is also covered against flaking This offer...

Страница 26: ...____________________________ MODEL ___________________________________ SERIAL NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy N...

Отзывы: