PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE

TECHNICAL MANUAL

50-1483

PELLET STOVE

Evolution-A

PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION 

AND USE OF THIS PELLET-BURNING ROOM HEATER. FAILURE TO 

FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY 

DAMAGE, BODILY INJURY OR EVEN DEATH.

Contact your building or fire officials about restrictions and installation 

inspection requirements in your area. 

Содержание Evolution-A

Страница 1: ...E TECHNICAL MANUAL 50 1483 PELLET STOVE Evolution A PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET BURNING ROOM HEATER FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE BODILY INJURY OR EVEN DEATH Contact your building or fire officials about restrictions and installation inspection requirements in your area ...

Страница 2: ...llation 12 Corner Through Wall Installation 12 Through Wall With Vertical Rise and Horizontal Termination Installation Recommended 14 Through Concrete Wall With Vertical Rise Installations 14 Inside Vertical Installations 15 Outside Vertical Installations 15 Hearth Mount Installation 16 Exterior Mounted Exhaust Blower 17 Typical Through Wall With Exterior Blower Kit Installation Horizontal Termina...

Страница 3: ...ider damper located on the left side of the stove When installing the stove in a mobile home it must be electrically grounded to the steel chassis of the home and bolted to the floor Make sure that the structural integrity of the home is maintained and all construction meets local building codes Minor soot or creosote may accumulate when the stove is operated under incorrect conditions such as an ...

Страница 4: ...s should be installed and maintained in the structure when installing and operating a pellet burning appliance OPERATION The ash pan and door must be closed securely for proper and safe operation of the pellet stove Also ensure all gaskets on the door are checked and replaced when necessary INSTALLATION Be sure to maintain the structural integrity of your home when passing a vent through walls cei...

Страница 5: ... 3 8 619 mm When not installing the optional Hearth Pad on the unit the minimum requirements for floor protection are a width of 243 8 depth of 263 8 Specifications DIMENSIONS Figure 1 Dimensions of EF5 RATING LABEL LOCATION The rating label is located on the inside of the ash pan cover 5 ...

Страница 6: ...chaud quand allumé Ne touchez pas les brûlures sévères peuvent résulter Tenez loin des enfants des vêtements des meubles de l essence ou d autres fluides produisant des vapeurs inflammables Consultez le manuel avec les instructions d installation et d opération DO NOT REMOVE THIS LABEL N ENLEVEZ PAS CETTE ETIQUETTE Floor Protection A B C D Backwall Sidewall INSTALLED AS A FREESTANDING STOVE MODEL ...

Страница 7: ...onal area An interior vent can be used with approved pipe passing through the ceiling and roof 5 Locate the stove in a large and open room that is centrally located in the house This will optimize heat circulation 6 The power cord is 8 feet 2 43 m long and may require a grounded extension cord to reach the nearest electrical outlet REMOVING PELLET STOVE FROM PALLET 1 Remove the right and left hand...

Страница 8: ... Minimum Alcove width 36 inches 91 cm Minimum Alcove height 48 inches 122 cm Maximum Alcove depth 48 inches 122 cm Install vent at clearances specified by the vent manufacturer Side Wall Back Wall A d j a c e n t W a l l 77 8 20cm 4 10cm 4 10cm 48 122cm 48 122cm 48 122cm These dimensions are minimum clearances but it is recommended that you ensure sufficient room for serving routine cleaning and m...

Страница 9: ...arth Pad Pedestal onto EF5 THERMOSTAT INSTALLATION 1 Install the wall thermostat in a location that is not to close too the unit but will effectively heat the desired area 2 Install a 12 or 24 Volt Thermostat using an 18 x 2 gauge wire from the unit to the thermostat If the unit has been placed in the HI LOW mode the unit will be taken to a low or idle setting when the thermostat is not calling fo...

Страница 10: ...termination locations Table 1 Use in conjunction with Figure 8 for allowable exterior vent termination locations Letter Minimum Clearance Description A 24 in 61 cm Above grass top of plants wood or any other combustible materials B 48 in 122 cm Beside below any door or window that may be opened 18 46 cm if outside fresh air installed C 12 in 30 cm Above any door or window that may be opened 9 23 c...

Страница 11: ...ed It is recommended when you are installing a fresh air system to keep the number of bends in the pipe to a minimum Installation FRESH AIR Figure 9 Outside Air Connection EXHAUST AND FRESH AIR INTAKE LOCATIONS The Exhaust Starter Tube can be installed 2 ways Angled towards the center Use a Tee with vertical for a centered vertical installation Straight out the back For horizontal thru the wall an...

Страница 12: ...an inside diameter of 4 inches 100 mm Installation MOBILE HOME INSTALLATION 3 7 5 cm 3 7 5 cm Fresh Air Intake Wall thimble manufactured by pellet vent manufacturer ENVIRO EF5 1 4 Lag Bolts Securely Fastened Ground Wire Directly to Metal Chassis Optional Hearth Pad Flooring Steel Frame Secure the heater to the floor using the two holes in the pedestal Ensure the unit is electrically grounded to th...

Страница 13: ... forget to place high temperature silicone around the pipe that passes through the thimble 9 Install a vertical pipe or if all requirements for direct venting are met install vent termination The stainless steel cap termination manufactured by the vent manufacturer is recommended However when the vent terminates several feet above ground level and there are no trees plants etc within several feet ...

Страница 14: ...all framing Wall thimble Termination cap Vertical section of vent pipe Horizontal frame for thimble Clean out tee 90o elbow EF 5 Concrete Wall A 45 elbow with a screen may be used in place of the termination cap or stainless steel termination hood Installation to use if there is a concrete or retaining wall in line with exhaust vent on pellet stove The termination must be 12 inches 30 cm from the ...

Страница 15: ...hole about 1 5 8 41 mm in diameter 5 Install the fresh air intake pipe 6 Install the tee with clean out 7 Install the pellet vent upward from there When you reach the ceiling make sure that the vent goes through the ceiling fire stop Maintain a 3 7 6 cm distance to combustibles and keep attic insulation away from the vent pipe Maintain an effective vapor barrier 8 Finally extend the pellet vent to...

Страница 16: ... shelf Installation Rain cap Flashing 24 61 cm 3 7 5cm Tee with cleanout Fresh air intake 3 7 5 cm Clearance Support bracket Type L vent Figure 17 Outside Vertical Installation Figure 18 Hearth mount installation Refer to Figures 18 1 Lock fireplace damper in the open position 2 Install a positive flue connector at the fireplace dampers 3 Connect a tee or a 90 elbow to the exhaust pipe 4 Install f...

Страница 17: ...ture silicone Fasten the box to the wall with 4 four screws seal edges of box to wall with clear silicone 6 Drill a hole through the wall thimble plate for the electrical wires Pass the armored cable through the wall thimble Use the strain relief provided Do not pass cable through vent hole 7 Install the Exhaust Blower motor into the external exhaust blower housing box Make the electrical connecti...

Страница 18: ...hole in the left hand rear hopper pillar Hook up to wires from the exhaust blower wiring harness All electrical connections must be in accordance to local code requirements NOTE Ensure that all vent connections are installed by placing a small bead of high temperature silicone at each chimney connection Also ensure that all vertical vent sections are properly supported and that all clearances to c...

Страница 19: ...damper rod and knob 7 16 Nut 7 16 Clinching Nut Slider damper plate slider damper rod remove the left cabinet side and locate the slider damper plate Install the 7 16 inch nut onto the slider damper rod thread all the way to the end of the threads on rod 2 Slide rod through the hole in the slider damper plate and install the 7 16 clinching nut onto the rod and tighten completely onto the slider da...

Страница 20: ...er operation SPECIAL NOTES Pellet quality is a major factor in how the Pellet stove will operate If the pellets have a high moisture content or ash content the fire will be less efficient and has a higher possibility of the fire building up and creating clinkers hard ash build up Air Intake Box Exhaust Channel Slider Damper Exhaust Blower Figure 27 Slider Damper Plate in Unit If the fire should ha...

Страница 21: ...d in the burn pot üCheck the Heat Level Indicator If the 2 light is flashing see the 2 light is flashing üCheck the fuse on the circuit board üIf the unit still does not start contact your local service dealer for service 2 The stove will not operate when hot üCheck the Heat Level Indicator if a fire is not detected or if the fire has gone out the 3 light will flash because the Exhaust Temperature...

Страница 22: ...is installed Check the operation by opening a window does this solve the problem If it does install fresh air intake to unit or room Venting system may require vertical section to move termination into a low pressure zone üVacuum Switch failure Bypass the vacuum switch if this corrects the problem check for above problems before replacing the Vacuum Switch üDamage to gray wires between Circuit Boa...

Страница 23: ... bright orange in color If not replace the ignitor 9 Control settings Heat Level has no effect on the fire üNOTE If the system light is flashing the Control Board has complete control of the unit When the units system light becomes solid then control of the unit is given back to the operator üIf there is no control of the Heat Level button make sure the thermostat is calling for heat üCall your lo...

Страница 24: ...Orange Orange Yellow Yellow Grey Grey Grey Grey Purple Purple Blue 115V Black 220V Brown Black Black Black Blue Black Armor Cable Supplied Vacuum Switch Combustion Blower Optional Exterior Exhaust Blower Power Cord Ground Ignitor Exhaust Temperature Sensor 5 Amp Fuse High Limit Temperature Sensor Convection Blower Auger Motor Common Hot Thermostat 24 ...

Страница 25: ...ulation Round Drop Tube EF5 124 7 Firebox Panel Set with Insulation Square Drop Tube 50 1474 8 Burn Pot EF5 128 9 Ash Pan EF5 129 10 Ash Pan Cover EF5 131 11 Ash Shelf Nickel EF5 132 12 Glass Retainer Set EF5 133 13 Door Handle EF5 134 14 Door Hinge Bracket EF5 135 15 Door Only Painted EF5 136 16 Slider Damper Plate EF5 137 17 Heat Exchange Rod EF5 138 18 Back Grill EF5 139 19 Hopper Lid Painted E...

Страница 26: ...ouver 50 162 Slider Damper Rod Knob 50 293 Top Glass Retainer 50 294 Control Panel Touch Latch 50 323 Circuit Board Stand Offs 50 331 Circuit Board Wire Harness 50 332 Hopper Guard 50 333 35 Convection Blower 115V No Mount 50 512 36 Convection Blower Mount Hardware 50 585 37 400 Watt Ignitor 115V 50 619 Auger Mounting Hardware 50 689 Auger Plate with Bushing 50 899 38 Exhaust Blower Assembly 115V ...

Страница 27: ...27 Parts Diagram Components Evolution Domestic Components July 2006 ...

Страница 28: ...Parts Diagram Steel Evolution Domestic Steel Components February 2005 28 ...

Страница 29: ...in restrictions and exclusions apply to this warranty Limited Two 2 Year Warranty Under this warranty Sherwood Industries Ltd covers Ignitor Auger Motor Circuit Board Timers Temp Sensors Blowers Vacuum Switch and Wire Harness against defects in materials and workmanship for part repair or replacement for the first two 2 years and limited labour for the first two 2 years to the original purchaser P...

Страница 30: ...lify the Limited Warranty on this stove If unsure as to the extent of this Limited Warranty contact your authorized Enviro dealer before installation 10 Sherwood Industries Ltd will not be responsible for inadequate performance caused by environmental conditions 11 The Limited Warranty does not cover installation and operational related problems such as spillage caused by environmental conditions ...

Страница 31: ...overed per our warranty service fee reimbursement schedule Labour rates are set per component and as such total labour costs may not be covered 27 Sherwood Industries Ltd is not liable for freight or labour on any stove replaced in field and is not liable for travel costs for service work In the event of in home repair work the customer will pay any in home travel fees or service charges required ...

Страница 32: ...RIAL NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy MAGNEHELIC AT INSTALL ___________________ INSTALLER S SIGNATURE _________________________________________ NAME OF INSTALLER _________________________________________ ADDRESS _________________________________________ _________________________________________ ________________...

Отзывы: