Enviro EG31 Nova Скачать руководство пользователя страница 7

Operating Instructions

For Your Safety, Read Safety Precautions And 

Lighting Instructions Before Operating

L

ighting

 i

nstRuctions

:

Figure 3: Gas Valve.

Figure 4: Pilot Burning.

1.   STOP! Read the safety information above on this label.
2.   Turn off all electrical power to this appliance.
3.   Turn off the gas control knob clockwise            to the off position.
4.   Open door. Wait fIve (5) minutes to clear out any gas. Close door. If
      you smell gas STOP! Follow  “B” in the  above safety information. If
      you do not smell gas go to the next step.
5.   Find pilot-located to the left under the front log. Turn the gas control
      knob counter-clockwise

      to “PILOT”. Push the gas control in fully

      and hold, keep knob depressed for about 30 seconds after 
      the pilot is lit. Release knob. If pilot goes out, repeat 
      steps 4 through 5.

CAUTION:

Hot while operating. Do not touch, severe burns may result. Keep children, clothing, 
furniture, gasoline or other  flammable vapors away.

FOR YOUR SAFETY READ BEFORE OPERATING

WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING

 PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. 

 A)  This appliance is equipped with a pilot, which must be lit by hand by
       following these instructions exactly. 
 B)  BEFORE LIGHTING smell all around the appliance area for gas and next to
       the floor because some gas is heavier than air and  will settle on the floor.    
   WHAT TO DO IF YOU SMELL GAS: 
       Do not try to light any appliance. Do not touch any electrical switch: do not
       use any phone in your building. Immediately call your gas supplier from a
       neighbor's phone. Follow  the gas suppliers instructions. If you cannot reach
       your gas supplier, call the fire department.

C)   Use only your hand to push in or turn the gas control knob; 
       NEVER use tools. If the knob will not push in or turn by hand, do 
       not try to repair it. Call a qualified service technician. Force or 
       attempted repair may result in a fire or explosion.
D)   Do not use this appliance if any part has been under water.
       Immediately call a qualified service technician to inspect the
       appliance and to replace any part of the control system and any
       gas control which has been under water.     

LIGHTING INSTRUCTIONS

 WARNING: this gas valve has a lockout device, which will not allow  the
    pilot burner to be relit until the thermocouple has cooled. If the knob does
    not pop up when released, stop and immediately call your service
    technician or gas supplier.
    If  the pilot does not stay lit after several tries, turn the gas control knob  
    to “OFF” and call your service technician or gas supplier.    
6.   Turn the gas control knob counter clockwise            to the  “ON”
      position. Flip the burner switch to “ON” THEN TURN THE “HI/LOW”
      knob to the desired setting.
7.   Turn on the electrical power to the unit.

TO TURN OFF GAS TO APPLIANCE

1. Flip burner switch to “OFF”
2. Turn the gas control knob clockwise             to the “OFF” position.

C-10489

3. Turn off all electrical power to the appliance if service is to be performed.

CAUTION:

 Do not operate this fireplace with the glass removed, cracked or broken. Replacement of the panel(s) should be done by a licensed or 

qualified person! This appliance needs fresh air for safe operation and must be installed with provisions for  combustion and ventilation air. See 
installation and operating instructions manual.  Keep burner and control compartment clean.

WARNING: 

Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage, or loss of life. Refer to owner's 

information manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or the gas supplier.
See installation and operating instructions accompanying appliance. Installation and service must be performed by a qualified installer, service agency, 
or the gas supplier.

O

L I

T

P

T

P

 T
H

      TP

   

   

 T

H

IN               

OUT

H

I

L

O

N

OF

O

F

LI

P

T

O

WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY 

RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OF LOSS OF LIFE.

Figure 2.  Lighting Instruction Label

7

Содержание EG31 Nova

Страница 1: ...personal injury or loss of life Installation and service must be performed by a qualified installer service agency or the gas supplier W A R R A N T Y R E G I S T R A T I O N e n v i r o c o m w a r r...

Страница 2: ...ll your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali...

Страница 3: ...erformed by a qualified installer service agency or gas supplier This installation must conform to local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 or t...

Страница 4: ...ze 14 Direct Vent Model 15 Direct Vent Restrictor Ring 15 Venting Fireplace Inserts 15 Automatic Flue Gas Spill Switch 17 Direct Vent Vertical Vent Termination 18 B Vent Model 19 Converting A Direct V...

Страница 5: ...G METHOD FOR MEASURING ANNUAL FIREPLACE EFFICIENCY This ENVIRO EG31 Fireplace Has been certified for use with either natural or propane gases See rating label Is not for use with solid fuels Is approv...

Страница 6: ...30 39 93 13 99 28 25 2 13 16 14 OR 14 41 18 27 OR 16 54 21 75 19 52 Install Depth If the available depth of install is less than the 16 14 shown above the stove depth can be reduced to 14 41 by removi...

Страница 7: ...re or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and...

Страница 8: ...minutes The speed of the fan can be changed by turning the fan control knob To turn the blower off turn the knob COUNTER CLOCKWISE until it clicks off It is advisable not to operate the blower below 1...

Страница 9: ...s cooled remove the face of the fireplace along with the glass See Maintenance And Service Glass Door Removal Check the gasket material on the back of the glass making sure that it is attached and int...

Страница 10: ...s located in the center of the burner tray see Figure 7 Slide tray to the left and lift out 3 Remove brick panels see Secondary Installation Brick Panels Installation 4 Remove the surround panel by li...

Страница 11: ...ed exactly a fire explosion or production of carbon monoxide may result causing property damage personal injury or loss of life The qualified service agency is responsible for the proper installation...

Страница 12: ...and glass door Also refer to Secondary Installation Installing Log Set and Embers When re installing the burner ensure that the burner to pilot hood relationship is similar to what is shown in Figure...

Страница 13: ...as been installed at an altitude higher than 2000ft 610m it is required to de rate the unit accordingly In the USA The appliance may be installed at higher altitudes Please refer to your American Gas...

Страница 14: ...mm from the bottom of unit If installed at floor level there must be a minimum of 16 406 mm of non combustible material in front of the unit Minimum ceiling clearance is 61 5 1562mm from bottom of un...

Страница 15: ...m Use the vent restrictor ring for installations above 15 feet 4 57 m See Figure 14 for installation of restrictor ring Venting Fireplace Inserts The ENVIRO EG31 may be installed and vented into any...

Страница 16: ...ch side of center line extended above meter regulator assembly 6 ft 1 83 m Radial clearance around service regulator vent outlet 12 in 30 cm Clearance above grade verandah porch deck or balcony 3 ft 0...

Страница 17: ...is heater is equipped with a vent safety shutoff system designed to protect against improper venting of combustion products This safety switch is located on the rear of the appliance close to the draf...

Страница 18: ...m flex vent over the flue collar and secure with three 3 sheet metal screws evenly spaced Note If fireplace opening is lower than 21 75 552 mm remove the vent collar plate from the top of the insert s...

Страница 19: ...eplace To A Direct Vented Fireplace Parts required for conversion 1 Drafthood 2 3 dual pipe chimney connector 2 Air channel cover plates 1 Drafthood cover plate 1 Remove the chimney connector 300 spil...

Страница 20: ...nscrewing the T 20 Torx screw located on the center top of the stove Slide collar plate backwards Properly secure the vent collar plate to the flexible vent pipe liner s previously installed in the ch...

Страница 21: ...GINAL FIREPLACE MAY NEVER BE RETURNED TO SOLID FUEL USE IN THIS CONDITION IMPORTANT If the factory built fireplace has no gas access hole s provided an access hole of 1 5 inch 37 5 mm or less may be d...

Страница 22: ...equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong outlet DO NOT cut or remove the grounding prong...

Страница 23: ...d from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at pressures equal to or less than psig 3 45 KPa Always...

Страница 24: ...uld the need arise follow Steps 1 2 below Figure 27 Proper Pilot Flame 3 8 1 2 10 13mm Thermocouple Proper Flame Adjustment Initial Installation QUALIFIED INSTALLERS ONLY 1 The adjustment screw can be...

Страница 25: ...n brackets will need to be removed as outlined in steps 1 3 below Secondary Installation Extension Brackets Removal REMOVAL 1 Using a T20 screwdriver remove the four 4 screws that secure the Top Exten...

Страница 26: ...are still installed Safety Screen Assembly 1 Attach the left right top bottom brackets onto the safety screen using a T20 screwdriver and the supplied sixteen 16 8 T20 screws see Figure 30 Do not over...

Страница 27: ...Installation Warning The surround becomes hot when the unit is operating ensure that the unit is turned off and that it has cooled to room temperature before begining this installation The safety scre...

Страница 28: ...tip to tip on the rest area One end of the big log twig will rest on the pin on the right log and the other will lay within the left rest area The small log twig should be placed so it sit completely...

Страница 29: ...left then up Gently pull right brick side panel inward from the bottom back Pull towards the back then out freeing it from the front retainer Caution The pilot may damage panel Remove left side panel...

Страница 30: ...replace thermocouple Air in gas line pilot dies while knob is depressed Bleed line Check gas line pressure Contact dealer Burners will not remain lit Problem with thermopile circuit Check gas line pr...

Страница 31: ...Orifice LP Threaded EC 020 3 Pilot Gasket EC 021 4 S I T Piezo Ignitor EC 023 Stainless Steel Flex Connector with Elbow 18 Long EC 024 5 FPI Burner Switch EC 026 6 FPI Fan Controller 115 V EC 039 6 F...

Страница 32: ...Relief Door Gasket 30 034 14 Blank Orifice 73 50 343 BV Flue Collar Gasket 50 528 DV Flue Collar Gasket 50 529 Log Set Embers 50 588 15 Ceramic Brick Liner 50 610 Dual Bulb Door Gasket 10 feet 50 634...

Страница 33: ...33 Parts Diagram Body Focus Components March 2008 14 15 16 2 1 3 17 4 5 6 7 8 10 9 11 12 13 18 EG31 Components...

Страница 34: ...Notes 34...

Страница 35: ...ler including serial number This warranty does not cover any discoloration of the safety screen mesh Exclusions An expanded list of exclusions is available at www enviro com help warranty html This wa...

Страница 36: ...____________________________ MODEL ___________________________________ SERIAL NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy N...

Отзывы: