Initial Installation
QUALIFIED INSTALLERS ONLY
Warning:
Failure to position the parts in accordance with this manual, or failure to use only parts
specifically approved with this appliance may result in property damage or personal injury.
c
LeaRances
to
c
ombustibLes
WARNING:
Operation of this heater when not connected to a properly installed and maintained
venting system can result in carbon monoxide (CO) poisoning and possible death.
Maintain sufficient clearances for operation, service
and maintenance.
• A minimum distance of 9” (229mm mm) is required
from the side of the unit to the sidewalls.
• A 8” (200 mm) wide mantel can be mounted at a
minimum height of 38” (965 mm) from the bottom
of unit.
• If installed at floor level there must be a minimum
of 16” (406 mm) of non-combustible material in
front of the unit.
• Minimum ceiling clearance is 61.5” (1562mm)
from bottom of unit.
Warning:
Clearances must be sufficient to allow
access for operation, maintenance and service.
Stove must sit on a non-combustible surface
m
inimum
F
iRepLace
s
ize
:
Table 3: Minimum dimensions of fireplace for EG31 to be installed into.
Width
Height
Depth
Fireplace Dimensions
34” (864 mm)
21” (533 mm)
18” (457 mm)
NOTE: Space must be provided for gas line on right side of unit for servicing purposes. The EG31 can
only be installed into masonary or zero-clearance fireplaces.
Figure 13: Mantle width and height.