19
Wire
spacers
Figure 25: Wire Spacers.
Cut the hole from the interior through the exterior wall surfaces.
4. Frame the hole as shown in Figure 29.
5. Trim the wall thimble to match the wall thickness as necessary. Install the
wall thimble and secure it to the inner wall frame using four (4) 1½” wood
screws. If a wall is greater than 8” (203mm) in depth, the clearance above
the flex must be 4⅜” (111mm)
6. Apply a bead of Mill-Pac Black sealant to the new Ø4” (10 cm) by 5” (12.5
cm) provided flue collar adaptor. Press the flue collar into the flue outlet of
Figure 26: Wire Spacer in Place.
the fireplace so that the Mill-Pac seals the
flue collar to the flue outlet.
7. Stretch both the Ø4” (10 cm) flex vent and
the Ø6⅝” (16.25 cm) flex intake liner to
the length needed to ensure the flex can be
easily connected to the vent terminal.
8. Slide the Ø6⅝” (16.25 cm) flex intake liner
over the flex vent. Install four (4) wire
spacers around the flex pipe. Ensure the
wire spacers are positioned at either end of
the pipes, and at each end of any elbows in
the liners (refer to Figure 25 and 26).
Initial Installation
QUALIFIED INSTALLERS ONLY
F
iRePLace
h
oRizontaL
v
ent
k
it
50-1235:
Please read and understand these instructions before installing. Failure to follow
these instructions carefully could cause property damage or personal injury.
The Fireplace Horizontal Vent Kit can be installed on the unit as rear vent or top vent.
KIT COMPONENTS:
Qnty
Description
Qnty
Description
1
Horizontal direct vent termination cap
4
Wire spacers
1
Flue collar adapter
1
4 oz tube Mill-Pac Sealant
1
Wall thimble
1
4 oz tube RTV silicone
1
5’ (190 cm) length of Ø4” (10 cm) double walled flex pipe
12
9/16” tech screws
1
5’ (190 cm) length of Ø6⅝” (16.8 cm) double walled flex pipe
8
1½” wood screws
Please ensure that all components are supplied with this kit. If components are missing or have
been damaged, contact your dealer, distributor, or courier company. Do not attempt the installation if
components are missing or damaged.
INSTALLATION INSTRUCTIONS:
1. Plan your installation and clearances to combustibles. Decide on a location for the unit that will meet
the clearances noted in the venting section, and any or all local code requirements.
NOTE:
Additional Flex Vent extension Kits can be added as long as the overall length stays within the
limits of the Vent Chart (refer to Figure 31).
2. Set the appliance in the desired location. Determine if any wall studs, electrical wiring, or plumbing
pipes are in the way of the venting system as it passes through the exterior wall. The fireplace location
should be adjusted if obstructions are found in the wall.
3. Project a line from the center point of the flue outlet upward and outward to the desired flue outlet
location on the exterior wall. Using this center point, scribe a 10” (25.4 cm) hole or square on the wall.