Maintenance And Service
8. Reinstall the burner, brick panels, log set, embers, and glass door.
Also refer to
S
econdary
i
nStallation
- i
nStallinG
l
oG
S
et
and
e
MberS
in your Owner’s Manual. When re-installing the burner, ensure that
the burner to pilot hood relationship is similar to what is shown in
Figure 14. On some units you will need to pay special attention when
installing the burner that the venturi adjustment rod is properly
installed into the venturi adjustment piece welded to the burner
venturi tube
Figure 13: O-ring on valve screw.
9. Reconnect the main gas line if it was disconnected and open the shut-off valve at the gas line to the
unit.
10. Use a small brush to apply a warm soapy water solution to all gas connections (use a half dish soap
and half warm water). If a gas leak is present, bubbling will occur. Gas leaks can be repaired by
using an approved pipe thread sealant or approved Teflon tape. NEVER USE AN OPEN FLAME WHEN
TESTING FOR LEAKS.
11. Reconnect the electrical power to the unit.
12. Relight the main burner in both the “HI” and “LO” positions to verify proper burner ignition and
operation and proper flame appearance. Also refer to
S
econdary
i
nStallation
- i
nStallinG
l
oG
S
et
and
e
MberS
in your Owner’s Manual for a flame appearance picture.
13. MAKE SURE that the conversion label is installed on or close to the rating label to signify that the
unit has been converted to a different fuel type.
Figure 14. Ignitor assembly
beside the burner.
g) Re-attach the black protection
cap that was removed in step
a (Figure 10).