background image

6. GAS LINE CONNECTIONS and TESTING 

WARNING:  Only persons licensed to work with gas piping may make the necessary gas connections to this appliance.   
 

GAS LINE CONNECTION

 

• 

This stove is equipped with a 3/8  x 3  inch black iron nipple located on the right side of the unit terminating in a 3/8" male 
NPT fitting. Consult your local authorities codes or the CAN/CGA B 149 (1 or 2) installation code in Canada, or in the USA 
gas installations follow either local codes or the current edition of the National Fuel Gas Code ANSI Z223.1. 

• 

The efficiency rating of this appliance is a product thermal efficiency rating determined under continuous operating 
conditions and was determined independently of any installed system. 

 
The appliance and its shutoff valves must be disconnected from the gas supply piping system during any pressure testing 
where the pressure exceeds 1/2 PSIG (3.45 kpa) or damage will occur to the valve. 
 
The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any 
pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa). 

 
Always check for gas leaks with a soap and water solution after completing the required pressure test. 
 
TO TEST VALVE PRESSURES 

 The pressure taps are located on the left side of the valve  

 

• 

Turn set screw 1 turn counter clockwise to loosen,.  

• 

Place 5/16" (8 mm) I.D. hose over pressure tap system.  

• 

Check pressures using a manometer. 

• 

When finished, release pressure, remove hose & tighten set screw. 

 
 

3/8” Pipe 

Gas Control Knob 

Manifold Pressure Tap 

Inlet Pressure Tap

Pilot Adjustment Screw 

Hi Low  Knob 

 

 

ORIFICE SIZES, PRESSURES AND BTU'S 

 

All models are equipped with a variable output gas control.

  

 

 NATURAL PROPANE 

MAIN BURNER ORIFICE: 

#42 DMS 

#53 DMS 

 

 

 

Manifold Press: 

3.8"wc / 0.95 kpa 

11.0"wc / 2.74 kpa 

Min. Manifold Press: 

1.1"wc / 0.27 kpa 

2.7"wc / 0.67 kpa 

Max. Supply Press: 

7.0"wc / 1.74 kpa 

12.0"wc/ 2.98 kpa 

Min. Supply Press: 

5.0"wc / 1.25 kpa 

11.5"wc / 2.86 kpa 

Max. BTUH Input: 

25,000 btu/h/ 7.32 Kw 

25,000 btu/h/ 7.32 Kw 

Min. BTUH Input: 

12,500 btu/h/ 3.66 Kw 

12,500 btu/h/ 3.66 Kw 

Output 

Fan on 18,875 btu/h/ 5.53kw 

Fan on, 19,250 btu/h/ 5.64kw 

 

Fan off 18,000 btu/h/ 5.27 kw 

Fan off 18375 btu/h/ 5.38kw 

NEVER USE AN OPEN FLAME FOR LEAK TESTING

 

 

9

Содержание ACCENT 25BV

Страница 1: ...formed by a qualified installer service agency or the gas supplier WHAT TO DO IF YOU SMELL GAS Open windows Extinguish any open flame Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire departmen...

Страница 2: ... the slight smoking stops Always connect this gas stove to a vent system and vent to the outside of the building envelope Never vent to another room or inside a building Make sure you use the vent pipe that is specified Make sure that the vent is properly sized and is of adequate height to provide the proper draft Inspect the venting system annually for blockage and any signs of deterioration Due ...

Страница 3: ...GAS FIREPLACE HEATER CANADA and U S A CERTIFIED FOR INSTALLATION FROM 0 2000 FT 810 M FOR INSTALLATIONS ABOVE 2000 FEET 810 m In Canada the unit must be derated by 10 for installation at elevations between 2 000 810 m and 4 500 feet 1370 m NATURAL GAS PROPANE GAS INPUT 20814 6 09 Kw 44 DMS INPUT 22257 6 52 Kw 54 DMS In the USA these appliance are certified for elevations up to 2 000 feet 810 m For...

Страница 4: ...t to fit Sherwood Industries Ltd Policy Intertek has approved listed factory built fireplaces as a certified zero clearance kit provided that the following conditions have been met 1 The removal of any part will not weaken the stuctural integrity of the factory built fireplace 2 The factory built fireplace is in good condition 3 There is no alterations in the form of cutting bending or breaking an...

Страница 5: ...APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVICING A SEPARATE SOLID FUEL BURNING APPLIANCE AUTOMATIC FLUE GAS SPILL SWITCH NOTE THIS HEATER MUST BE PROPERLY CONNECTED TO A VENTING SYSTEM THIS HEATER IS EQUIPPED WITH A VENT SAFETY SHUTOFF SYSTEM DESIGNED TO PROTECT AGAINST IMPROPER VENTING OF COMBUSTION PRODUCTS THIS SAFETY SWITCH IS LOCATED ON THE REAR OF THE APPLIANCE CLOSE TO THE DRAFT ...

Страница 6: ... the height of the chimney Make sure that all chimney clean outs are tightly fitting and will not permit air to leak into the chimney The chimney must be clean in good working order and constructed out of non combustible materials Any flue damper must be removed or blocked permanently in the open position Remove the vent collar plate from the top of the insert and connect it securely with sheet me...

Страница 7: ...previously installed in the chimney using 3 three sheet metal screws Be careful not to over stretch the liner 7 Place the unit part way into the fireplace Connect the fireplace insert s rigid gas line to the household gas supply using locally approved methods Place the electric cable so it can be connected to the power supply Adjust the leveling legs 8 Slide the insert into the fireplace ensuring ...

Страница 8: ...Remove the burner tray assembly by removing the two 2 screws on either side of the tray Pull tray up at the back and lift out 2 Disconnect the gas line to the nipple Remove the three 3 screws holding the burner control tray to the back firewall Lift tray up on left side and pull out 3 Pull blower towards you Disconnect wires from the blower and remove 4 To re install perform the preceding steps in...

Страница 9: ... during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa Always check for gas leaks with a soap and water solution after completing the required pressure test TO TEST VALVE PRESSURES The pressure taps are located on the left side of the valve Turn set screw 1 turn counter clockwise to loosen Place 5 16 8 mm I D hose over pressure tap sys...

Страница 10: ...er material from the plastic bag Place a single line of embers on burner as shown beside 4 Carefully avoid any clumping or large build ups Do not pack down leave embers loose 5 Upon the first light up watch for ignition to all burner ports If a long delay is noted First wait for the appliance to cool down Open the front door of the appliance Check to carefully reposition the embers making sure tha...

Страница 11: ...off all electrical power to the appliance 3 Turn the gas control knob clockwise to the off position 4 Open door Wait five 5 minutes to clear out any gas Close door If you smell gas including near the floor STOP Follow B in the above safety information If you don t smell gas go to next step 5 Find the pilot located to the right between the front and rear burner 6 Turn gas control knob counter clock...

Страница 12: ...m corner Close door Glass must be purchased from an Envirogas dealer No substitute materials are allowed CLEANING THE INSIDE OF THE FIREBOX Remove the log carefully from the firebox Gently remove the embers and place on a piece of paper towel Until ready to replace Vacuum the bottom of the firebox thoroughly Carefully clean off any dust on the logs and brick panels and remove any lint from the mai...

Страница 13: ...Install the new pilot injector for the fuel being used BE CAREFUL WHEN TIGHTENING THE PILOT FITTING YOU COULD BREAK THE CERAMIC IGNITER ELECTRODE STEP 6 Re install the pilot assembly in the reverse order of STEP 5 STEP 7 Remove the main burner orifice using a deep socket STEP 8 Install the new orifice supplied Be sure to put a bead of pipe thread sealant or approved Teflon tape on the orifice befo...

Страница 14: ...k gas line pressure Contact dealer Burners will not remain lit Problem with thermopile circuit Check gasline pressure Check for flame impingement on thermopile if low see Pilot will not stay lit Check thermopile for a Minimum of 300 mV when burner switched on Check wiring to thermostat for breaks BV only Check for spillage at draft hood that may trip spill switch Flame lifting Leak in vent pipe Im...

Страница 15: ...40 Thermopile EG25 041 SIT Nova 820 Valve NG 50 turndown EG25 042 SIT Nova 820 Valve LPG 50 turndown EG25 043 NOVA Pilot with Ignitor Electrode Natural Gas EG25 044 NOVA Pilot with Ignitor Electrode Liquid Propane EG25 052 Burner Controls Complete NG EG25 053 Burner Controls Complete LPG EG25 062 3 x 3 8 Black Iron Pipe Nipple EG25 065 Burner Tray EG25 070 ENVIROGAS EG25 Nameplate EG25 072 Log Set...

Страница 16: ... 010 PAN BURNER POST APR 2000 120 F 49 C FAN TEMPERATURE SENSOR EC 001 BRICK CLIPS AND BACK LEDGE VALVE MOUNT CERAMIC BRICK LINERS EG25 074 SIT NOVA 820 GAS VALVE EC 006 NG EC 007 LP DRAFT HOOD SLIDER CONVECTION BLOWER EC 069 MAIN BURNER ORIFICE EC 022 ACCENT 25 INSERT EXPLODED VIEW PAGE 2 of 2 JUNE 2002 PIEZO IGNITER EC 023 CONVECTION BLOWER MOUNT EC 028 RATING LABEL PLATE LEVELING LEGS X 2 300 F...

Страница 17: ...TRIM PAINTED TRIM 50 107 BRASS TRIM 50 011 NICKEL TRIM 50 012 BRASS TRIM CORNER BRACKETS EC053 ACCENT 25 EXPLODED VIEW SURROUND PANELS PAGE 1of 2 JUNE 2002 ON OFF THERMOSTAT SWITCH BURNER SWITCH EC 026 NOT SHOWN ACCENT 25 OVERSIZE SURROUND WITH PAINTED TRIM 50 108 BRASS TRIM 50 013 NICKEL TRIM 50 014 ...

Страница 18: ...s only thereafter The paint on the Metal Brick Liner may peel This is due to the extreme conditions applied to the paint and is no way covered under warranty Your dealer shall make all claims under this warranty in writing A TO A MAXIMUM OF SEVEN YEARS WHEN FILING A WARRANTY CLAIM PLEASE COMPLETE THE FOLLOWING INFORMATION ON AN OFFICIAL WARRANTY CLAIM FORM To the Dealer Name address and telephone ...

Страница 19: ...____________________ Name of Installer ___________________________________________ Address ___________________________________________ ___________________________________________ ___________________________________________ Phone _____________________________________ Model ___________________________________ Serial Number __________________ Date of Purchase __________ ________ ________ Date of Inst...

Отзывы: