![Enviro ACCENT 25BV Скачать руководство пользователя страница 3](http://html.mh-extra.com/html/enviro/accent-25bv/accent-25bv_owners-manual_2415688003.webp)
TABLE OF CONTENTS
SECTION
PAGE
1. Code
Approvals
3
2. Dimensions and Clearances to Combustibles
5
3. Venting
6
4. Assembly and Installation Instructions
7
5. Electrical
Requirements
8
6. Gas Line Connection and Testing
9
7. Installation of Log Sets and Embers and Brick Panels
10
8. Operating
Instructions
11
9. Routine Maintenance and Service
12
10. Fuel Conversion
13
11. Trouble
Shooting
14
12. Parts and Accessories
15
13. Warranty
16
14. Installation Data Sheet
17
1. CODES AND APPROVALS
VENTED
type is identified by the suffix BV
. This appliance draws in room air for combustion and vent dilution
air.
•
These appliances have been tested by Intertek Testing Services. and found to comply with the established standards for
GAS FIRED VENTED ROOM HEATER in CANADA and the USA as follows:-
LISTED VENTED ROOM HEATER (EG 25 BV Nat. & LPG )
TESTED TO: ANSI Z21.88-1998 CSA 2.33.M98 VENTED GAS FIREPLACE HEATER
CANADA and U.S.A.
CERTIFIED FOR INSTALLATION FROM 0 - 2000 FT (810 M)
FOR INSTALLATIONS ABOVE 2000 FEET (810 m)
•
In Canada the unit must be derated by 10% for installation at elevations between 2,000 (810 m)and 4,500
feet (1370 m).
NATURAL
GAS
PROPANE
GAS
INPUT: 20814 (6.09 Kw) #44 DMS
INPUT: 22257 (6.52 Kw) #54 DMS
•
In the USA, these appliance are certified for elevations up to 2,000 feet (810 m). For elevations above 2,000
feet (810 m), input should be reduced 4% for each 1,000 feet (405 m) above sea level.
ACCENT 25
•
Has been certified for use with either natural or propane gases. (see rating label.)
•
Is not for use with solid fuels.
•
Is approved for bedroom or bedsitting room. (A thermostat must be installed in Canada.)
•
Must be installed in accordance with local codes.
If none exist use current installation code CAN/CGA B149 in Canada or ANSI Z223.1/NFPA 54 in the USA.
•
Must be properly connected to a venting system
WARNING: For installation only in a solid fuel burning fireplace with a working flue and
constructed of non-combustible material using a chimney liner kit.
3