background image

Operating Instructions

O

PERATING

 Y

OUR

 P

ELLET

 S

TOVE

:

PRE-BURN INSTRUCTIONS

: The burn pot liner holes must be clear and the liner installed properly 

against the ignitor tube for proper operation.  Check the hopper for enough pellets to start the unit. 

 

DO NOT OPERATE THE UNIT WITH THE DOOR OR ASH PAN OPEN. 

Note: 

The thermostat mode can be changed during normal operation.

MANUAL MODE:

All control of circuit board function is adjusted at the circuit board.

To START:

 Press the ON / OFF button. The stove will turn on. The 

system light will flash. The Auger Light will flash with each pulse of 

the auger (the Auger Feed Rate is pre-programmed during start-up). 

The Heat Level Indicator will show the Heat Level that the stove will 

run at after start-up.

If this is the first time the unit has been started or the unit has run out of fuel, the auger will need to 

be primed.  Press the Manual Auger Feed button until fuel starts to drop into the Burn Pot Liner (see 

O

PERATING

 I

NSTRUCTIONS

; C

ONTROL

 B

OARD

 F

UNCTIONS

”). 

To OPERATE: 

When a fire has been established, the System Light will turn solid (after approximately 10 

- 15 minutes) and the Auger Light will continue to flash to the corresponding Heat Level setting. The Heat 

Level button can now be pressed at this time to change the desired Heat Level Output setting. 

The convection blower (room air blower) will turn on. The speed of this blower is controlled by the setting 

of the heat level output indicator. The convection blower can be turned OFF by depressing the convection 

blower control button. For the best efficiency and to prevent cycling, the convection blower should be 

left on at all times.

When operating on LOW HEAT LEVEL, the feed rate can be adjusted, using the auger trim, for different 

quality fuels. These settings can be used if the fire keeps going out on low (poor quality fuel). Or if the 

low setting is too hot for the room (see “

O

PERATING

 I

NSTRUCTIONS

; C

ONTROL

 B

OARD

 F

UNCTIONS

”). 

Figure 3: Thermostat Switch in 

MANUAL poition.

Figure 4: Thermostat Switch in 

HIGH/LOW poition.

HIGH/LOW MODE:

 (Requires a thermostat)  

INITIAL START-UP

: See manual mode above.

OPERATION

:  When  the  thermostat  calls  for  heat  (contacts  are 

closed) the stove settings are adjustable as per Manual Mode.  When 

the thermostat contacts open, the HEAT LEVEL and Fans will drop 

down to the LOW setting until the thermostat contacts close again.  

*The LOW heat setting can be adjusted for different fuel qualities 

(see “

O

PERATING

 I

NSTRUCTIONS

 - C

ONTROL

 B

OARD

 F

UNCTIONS

”). The stove will 

come back to the previous HEAT LEVEL setting when the thermostat contacts close again.       

AUTO/OFF MODE:

 (Requires a thermostat)  

INITIAL START-UP

:  See manual mode above.

 







 







1

2

3

4

5

6

7

8

9

 







 







 







 







1

2

3

4

5

6

7

8

9

 







 







8

Содержание 50-1021

Страница 1: ...NS COULD RESULT IN PROPERTY DAMAGE BODILY INJURY OR EVEN DEATH Contact your building or fire officials about restrictions and installation inspection requirements in your area SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY THIS MANUAL IS PRINTED ON RECYCLED PAPER PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE OWNER S MANUAL 50 1021 ...

Страница 2: ...Dimensions 6 Rating Label Location 6 Operating Instructions 7 Control Board Functions 7 Automatic Safety Features of Your Pellet Stove 7 Operating Your Pellet Stove 8 Turning Your Pellet Stove Off 9 Slider Damper Set Up 9 Routine Cleaning and Maintenance 11 Warranty 14 Installation Data Sheet 15 Table of Contents ...

Страница 3: ...maximum Ash Content 1 maximum Premium grade 3 maximum Standard grade Moisture Content 8 maximum Heat Content approximately 8200 Btu per pound minimum ASH The ash content of the fuel and operation of your stove will directly determine the frequency of cleaning The use of high ash fuels may result in the stove needing to be cleaned daily A low ash fuel may allow longer intervals between cleaning CLI...

Страница 4: ...sure that the structural integrity of the home is maintained and all construction meets local building codes Minor soot or creosote may accumulate when the stove is operated under incorrect conditions such as an extremely rich burn black tipped lazy orange flames If you have any questions with regard to your stove or the above mentioned information please feel free to contact your local dealer for...

Страница 5: ...ds to start or freshen up a fire in the heater Keep all such liquids well away from the heater while it is in use SMOKE DETECTOR Smoke detectors should be installed and maintained in the structure when installing and operating a pellet burning appliance OPERATION The ash pan and door must be closed securely for proper and safe operation of the pellet stove Also ensure all gaskets on the door are c...

Страница 6: ... 3 8 619 mm When not installing the optional Hearth Pad on the unit the minimum requirements for floor protection are a width of 243 8 depth of 263 8 Specifications DIMENSIONS Figure 1 Dimensions of EF5 6 RATING LABEL LOCATION The rating label is located on the inside of the ash pan cover ...

Страница 7: ... will turn off after 60 seconds and then must be released and pressed again 5 SYSTEM LIGHT Responsible for signaling the state of the control board When the light is flashing during start up the stove is in an automatic start mode When the light is solid the Heat Level Setting can be altered 6 ON OFF BUTTON Used to turn the unit ON and OFF 7 HEAT LEVEL ADJUSTMENT When pressed will change the heat ...

Страница 8: ...his time to change the desired Heat Level Output setting The convection blower room air blower will turn on The speed of this blower is controlled by the setting of the heat level output indicator The convection blower can be turned OFF by depressing the convection blower control button For the best efficiency and to prevent cycling the convection blower should be left on at all times When operati...

Страница 9: ...s more air Open slider pull out slightly A short brisk flame like a blowtorch has too much air Close slider push in slightly Figure 5 Thermostat Switch in ON OFF poition 1 2 3 4 5 6 7 8 9 OPERATION When the thermostat contacts close the unit will light automatically Once up to temperature the stove operates the same as in MANUAL When the thermostat contacts open the stove s HEAT LEVEL and Fans wil...

Страница 10: ... liner s holes Then dispose of the scrapped ashes from the liner and from inside the burn pot Place the burn pot back into the stove making sure that the pipes are properly inserted into the burn pot Place the liner back into the burn pot making sure that the ignitor hole in the liner is aligned with the ignitor tube Pushing the liner up against the ignitor tube If after long periods of burning th...

Страница 11: ... dry soft cloth If the glass has build up that can not be removed with only the cloth clean the glass using paper towel and a gas appliance glass cleaner this may be purchased through most dealers If a gas appliance glass cleaner is not available use a damp paper towel dipped in fly ash to clean the glass After the glass has been cleaned use the dry soft cloth to wiping down the outside and inside...

Страница 12: ...inished using the pellet appliance for the season unplug the stove for added electrical protection It is very important that the stove be cleaned and serviced as stated above CLEANING PLATED SURFACES Please clean all fingerprints off of all plated parts with denatured alcohol on a soft cloth before firing the unit each time Fingerprints etc can become permanently etched into the plating if not rem...

Страница 13: ... THE COMPLAINT DEFECT PERIODICAL MALFUNCTION ETC The limited warranty covers defects in materials and workmanship as long as the products has been installed according to the manual s instruction If the product is damaged or broken as a result of mishandling or misuse the warranty does not apply Removal and re installation costs are not covered under this warranty It is the manufacturer s option wh...

Страница 14: ...L NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy MAGNEHELIC AT INSTALL ___________________ INSTALLER S SIGNATURE _________________________________________ NAME OF INSTALLER _________________________________________ ADDRESS _________________________________________ _________________________________________ ___________________...

Отзывы: