background image

Introduction

ASHES:

 Disposed ashes should be placed in a metal container with a tight fitting lid. The closed container 

of ashes should be on a non-combustible floor on the ground, well away from all combustible materials 

pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally dispensed, they 

should be retained in the closed container until all cinders have been thoroughly cooled.

ELECTRICAL:  The  use  of  a  surge  protected  power  bar  is  recommended. 

The  unit  must  be 

grounded. The grounded electrical cord should be connected to a standard 115 volts (4.7 Amps), 60 

hertz electrical outlet.  Be careful that the electrical cord is not trapped under the appliance and that it is 

clear of any hot surfaces or sharp edges and also must be accessible. If this power cord should become 

damaged, a replacement power cord must be purchased from the manufacture or a qualified ENVIRO 

dealer. This unit’s maximum power requirement is 540 watts.

GLASS:

 Do not abuse the glass by striking or slamming the door.  Do not attempt to operate the stove 

with broken glass. The stove uses ceramic glass. Replacement glass must be purchased from an ENVIRO 

dealer.  Do not attempt to open the door and clean the glass while the unit is in operation or if glass is 

hot. To clean the glass, use a soft cotton cloth and mild window cleaner, gas or wood stove glass cleaner, 

or take a damp paper towel and dip into the fly ash. This is a very mild abrasive and will not damage the 

glass.

FLAMMABLE  LIQUIDS:

 

Never 

use  gasoline,  gasoline-type  lantern  fuel,  kerosene,  charcoal  lighter 

fluid, or similar liquids to start or “freshen up” a fire in the heater.  Keep all such liquids well away from 

the heater while it is in use.

SMOKE  DETECTOR:

  Smoke  detectors  should  be  installed  and  maintained  in  the  structure  when 

installing and operating a pellet burning appliance.

OPERATION:

 The ash pan and door must be closed securely for proper and safe operation of the pellet 

stove. Also ensure all gaskets on the door are checked and replaced when necessary.  

KEEP ASH PAN FREE OF RAW FUEL. 

DO NOT PLACE UNBURNED OR NEW PELLET FUEL IN ASH PAN. A fire in the ash pan may occur.

INSTALLATION:

 Be sure to maintain the structural integrity of your home when passing a vent through 

walls, ceilings, or roofs. It is recommended that the unit be secured into its position in order to avoid any 

displacement.

DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT.

DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.

FRESH AIR:

 Outside Fresh Air connection is optional. Must be connected to all units installed in Mobile 

and “Air Tight Homes” (R2000) or where required by local codes. Consider all large air moving devices 

when installing your unit and provide room air accordingly. Limited air for combustion may result in poor 

performance, smoking and other side effects of poor combustion.

If you have any questions with regards to your stove or the above-mentioned information, please feel 

free to contact your local dealer for further clarification and comments.

SINCE  SHERWOOD  INDUSTRIES  LTD.  HAS  NO  CONTROL  OVER  THE  INSTALLATION  OF 

YOUR STOVE, SHERWOOD INDUSTRIES LTD. GRANTS NO WARRANTY IMPLIED OR STATED 

FOR  THE  INSTALLATION  OR  MAINTENANCE  OF  YOUR  STOVE.  THEREFORE,  SHERWOOD 

INDUSTRIES LTD. ASSUMES NO RESPONSIBILITY FOR ANY CONSEQUENTIAL DAMAGE(S).

SAVE THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE

5

Содержание 50-1021

Страница 1: ...NS COULD RESULT IN PROPERTY DAMAGE BODILY INJURY OR EVEN DEATH Contact your building or fire officials about restrictions and installation inspection requirements in your area SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY THIS MANUAL IS PRINTED ON RECYCLED PAPER PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE OWNER S MANUAL 50 1021 ...

Страница 2: ...Dimensions 6 Rating Label Location 6 Operating Instructions 7 Control Board Functions 7 Automatic Safety Features of Your Pellet Stove 7 Operating Your Pellet Stove 8 Turning Your Pellet Stove Off 9 Slider Damper Set Up 9 Routine Cleaning and Maintenance 11 Warranty 14 Installation Data Sheet 15 Table of Contents ...

Страница 3: ...maximum Ash Content 1 maximum Premium grade 3 maximum Standard grade Moisture Content 8 maximum Heat Content approximately 8200 Btu per pound minimum ASH The ash content of the fuel and operation of your stove will directly determine the frequency of cleaning The use of high ash fuels may result in the stove needing to be cleaned daily A low ash fuel may allow longer intervals between cleaning CLI...

Страница 4: ...sure that the structural integrity of the home is maintained and all construction meets local building codes Minor soot or creosote may accumulate when the stove is operated under incorrect conditions such as an extremely rich burn black tipped lazy orange flames If you have any questions with regard to your stove or the above mentioned information please feel free to contact your local dealer for...

Страница 5: ...ds to start or freshen up a fire in the heater Keep all such liquids well away from the heater while it is in use SMOKE DETECTOR Smoke detectors should be installed and maintained in the structure when installing and operating a pellet burning appliance OPERATION The ash pan and door must be closed securely for proper and safe operation of the pellet stove Also ensure all gaskets on the door are c...

Страница 6: ... 3 8 619 mm When not installing the optional Hearth Pad on the unit the minimum requirements for floor protection are a width of 243 8 depth of 263 8 Specifications DIMENSIONS Figure 1 Dimensions of EF5 6 RATING LABEL LOCATION The rating label is located on the inside of the ash pan cover ...

Страница 7: ... will turn off after 60 seconds and then must be released and pressed again 5 SYSTEM LIGHT Responsible for signaling the state of the control board When the light is flashing during start up the stove is in an automatic start mode When the light is solid the Heat Level Setting can be altered 6 ON OFF BUTTON Used to turn the unit ON and OFF 7 HEAT LEVEL ADJUSTMENT When pressed will change the heat ...

Страница 8: ...his time to change the desired Heat Level Output setting The convection blower room air blower will turn on The speed of this blower is controlled by the setting of the heat level output indicator The convection blower can be turned OFF by depressing the convection blower control button For the best efficiency and to prevent cycling the convection blower should be left on at all times When operati...

Страница 9: ...s more air Open slider pull out slightly A short brisk flame like a blowtorch has too much air Close slider push in slightly Figure 5 Thermostat Switch in ON OFF poition 1 2 3 4 5 6 7 8 9 OPERATION When the thermostat contacts close the unit will light automatically Once up to temperature the stove operates the same as in MANUAL When the thermostat contacts open the stove s HEAT LEVEL and Fans wil...

Страница 10: ... liner s holes Then dispose of the scrapped ashes from the liner and from inside the burn pot Place the burn pot back into the stove making sure that the pipes are properly inserted into the burn pot Place the liner back into the burn pot making sure that the ignitor hole in the liner is aligned with the ignitor tube Pushing the liner up against the ignitor tube If after long periods of burning th...

Страница 11: ... dry soft cloth If the glass has build up that can not be removed with only the cloth clean the glass using paper towel and a gas appliance glass cleaner this may be purchased through most dealers If a gas appliance glass cleaner is not available use a damp paper towel dipped in fly ash to clean the glass After the glass has been cleaned use the dry soft cloth to wiping down the outside and inside...

Страница 12: ...inished using the pellet appliance for the season unplug the stove for added electrical protection It is very important that the stove be cleaned and serviced as stated above CLEANING PLATED SURFACES Please clean all fingerprints off of all plated parts with denatured alcohol on a soft cloth before firing the unit each time Fingerprints etc can become permanently etched into the plating if not rem...

Страница 13: ... THE COMPLAINT DEFECT PERIODICAL MALFUNCTION ETC The limited warranty covers defects in materials and workmanship as long as the products has been installed according to the manual s instruction If the product is damaged or broken as a result of mishandling or misuse the warranty does not apply Removal and re installation costs are not covered under this warranty It is the manufacturer s option wh...

Страница 14: ...L NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy MAGNEHELIC AT INSTALL ___________________ INSTALLER S SIGNATURE _________________________________________ NAME OF INSTALLER _________________________________________ ADDRESS _________________________________________ _________________________________________ ___________________...

Отзывы: