background image

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.

B Y :   S H E R W O O D   I N D U S T R I E S   L T D

OWNER’S MANUAL

PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE

Venice

Wood Stove

Models: 1200-V & 1700-V Insert

Tested &

Listed By

Beaverton

Oregon USA

OMNI-Test Laboratories, Inc,

C

O-T L

PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS WOOD 

BURNING ROOM HEATER. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT 

IN PROPERTY DAMAGE, BODILY INJURY OR EVEN DEATH.

Contact your local building or fire officials, 

or the authority having jurisdiction about 

restrictions and installation inspection 

requirements in your area. 

This heater meets the U. S. Environmental Protection Agencies emission limits 

for wood heaters sold after July 1st, 1990. Under specific conditions this heater 

has been shown to deliver heat at rates ranging from 11,479 to 34,196 BTU per 

hour for the 1200-V and from 9,425 to 31,780 BTU per hour for the 1700.

50-1040

INSTALLER:

  

Leave this manual with the wood stove.

CONSUMER: 

Retain this manual for future reference.

Содержание 1200-V Insert

Страница 1: ...THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE BODILY INJURY OR EVEN DEATH Contact your local building or fire officials or the authority having jurisdiction about restrictions and installation in...

Страница 2: ...tallation 15 Removal From Pallet 15 Modifications For Installation with 191 16 484mm High Lintel 15 Masonry Fireplace Installation 16 Installation Using A Block Off Plate For USA Only 19 Model 1200 V...

Страница 3: ...supplied through either the bottom or the back of the pedestal Do not burn coal or charcoal as there is danger of carbon monoxide being produced Do not use chemical fluids to start or re fresh the fir...

Страница 4: ...eration the center position is off and when pushed down it will be set to automatic 3 In automatic mode set the rotary switch to the desired setting once operating temperature is reached the fan tempe...

Страница 5: ...on of your stove will help to ensure safe efficient heating Please take a few moments to review these simple operating procedures IMPORTANT Please be aware when loading your stove that the air tubes i...

Страница 6: ...mum fuel occurs when the stove top temperature is between 250 F 120 C and 550 F 290 C The most likely causes of dirty glass are not enough fuel to get the stove thoroughly hot burning green or wet woo...

Страница 7: ...s 5 pounds 2 3 Kg of water To season firewood split and stack it so that air can get to all parts of the wood Burn beach wood only if its salt content has been washed away in a season of rain and then...

Страница 8: ...e a home too airtight An easy way to stop negative pressure in a home is to crack a window in the room containing the stove b Environmental Conditions High trees low lying house location such as in a...

Страница 9: ...gh Twin pilot injection ports Slider plate used for air flow control Intake air Seasoned Firewood Exhaust Smoke 1 2 Ceramic baffle reflects heat down to burn the particles in the smoke Secondary air t...

Страница 10: ...t 461 8 x 28 1171 mm x 711 mm Oversized width x height 461 8 x 331 8 1171 mm x 843 mm Rating Label Location Side of Unit Behind Right Shroud 10 Specifications AIR CONTROL The air wash and pilot air co...

Страница 11: ...m by non combustible spacers 14 357 mm Ceramic tiles or eqivalent non combustible material on non combustible supports with a minimum of 013 0 33mm sheet metal spaced out 1 25mm by non combustible spa...

Страница 12: ...by non combustible spacers 161 8 408 mm Ceramic tiles or eqivalent non combustible material on non combustible supports with a minimum of 013 0 33mm sheet metal spaced out 1 25mm by non combustible sp...

Страница 13: ...1200 V INSERT 34 13 16 885mm 19 1 16 484mm or 19 9 16 497mm 22 5 16 566mm 26 15 16 684mm 20 7 8 530mm 47 3 8 1203mm 20 7 8 529mm 21 9 16 548mm 5 127mm 13 5 16 338mm 20 1 16 509mm 21 15 16 557mm Figur...

Страница 14: ...700 V INSERT 34 13 16 885mm 19 1 16 484mm or 19 9 16 497mm 22 5 16 566mm 26 15 16 684mm 20 7 8 530mm 47 3 8 1203mm 20 7 8 529mm 26 1 8 663mm 5 127mm 17 7 16 453mm 24 9 16 624mm 26 1 2 672mm Figure 5 1...

Страница 15: ...his is done to make unit burn more efficiently Figure 7 Rivet Figure 6 Bolts to remove 15 MODIFICATIONS FOR INSTALLATION WITH 191 16 484MM HIGH LINTEL Insert Cabinet Top Air Deflector Figure 9 Removin...

Страница 16: ...ainless steel liner that goes directly to the top of the chimney and is covered with a rain cap The chimney top is sealed with a flashing or steel plate that supports the weight of the chimney liner T...

Страница 17: ...ure 12 Insert Installation into existing floor level masonry fireplace Installation Floor Protection Combustible Floor Masonry Fireplace 8 203 mm USA 16 406 mm CND 18 450 mm Figure 11 Insert Installat...

Страница 18: ...e gasket cement When the face plate is installed onto the unit the insulation must overlaps the fireplace opening to form a seal between the masonry fireplace and the unit s face plate Let the silicon...

Страница 19: ...front of the fireplace opening Refer to Step 3 NOTE In general masonry fireplaces have square fireboxes while zero clearance metal fireplaces have domed firebox tops Therefore zero clearance block of...

Страница 20: ...off plate Damper must be removed Zero clearance metal firebox IMPORTANT DO NOT modify any part of the ZC fireplace 7 After installing the unit into place and the pipe through the block off plate use h...

Страница 21: ...left until the right end of the tube is freed To installation a secondary air tube reverse the above instructions IMPORTANT All secondary air tubes must be in place for proper operation Partial Brick...

Страница 22: ...the right end of the tube is freed To installation a secondary air tube reverse the above instructions IMPORTANT All secondary air tubes must be in place for proper operation Full Size Brick Partial B...

Страница 23: ...m the plug DO NOT route the power cord beneath the heater WARNING This appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged into a pro...

Страница 24: ...e the four 4 1 2 hex head screws that hold the fan mounting plate to the shroud If doing a fan only replacement remove the four 4 T 20 screws holding the fan to the fan mounting plate 3 Remove the fan...

Страница 25: ...Loosen but do not remove the four 4 1 4 screws holding the cast top 2 List the cast top off the unit and place to the side 3 Loosen the four 4 torx T 20 screws holding the face on the unit 4 Lift the...

Страница 26: ...standards Install and use only in accordance with the manufacturers installation and operating instructions Contact local building or fire officials about restrictions and installation inspection in...

Страница 27: ...50 1105 16 Glass Retainer Kit With Screws 50 1122 17 1200 1700 Left Shield Assembly 50 1144 18 1200 1700 Right Shield Assembly 50 1145 19 1200 C Cast Ceramic Baffle 1 Piece 50 1146 20 1700 C Cast Cera...

Страница 28: ...28 Parts Diagram 10 11 13 12 4 25 5 3 2 1 17 7 18 23 21 29 26 22 6 32 33 16 31 34 28 30 27 8 19 20 9 9 14 15 24...

Страница 29: ...l purchaser Please see the exclusions and limitation section below as certain restrictions and exclusions apply to this warranty How the Warranty Works 1 All warranties by the manufacturer are set her...

Страница 30: ...ty will cover glass thermal breakage only and will not cover misuse of the stove glass including but not limited to a Glass that is struck has surface contaminates or has had harsh or abrasive cleaner...

Страница 31: ...esentations 24 Sherwood Industries Ltd will not cover the cost of the removal or re installation of the stove hearth facing mantels venting or other components 25 Labour to replace or repair items und...

Страница 32: ..._________________ _________________________________________ PHONE ___________________________________ MODEL ___________________________________ SERIAL NUMBER ___________________________ DATE OF PURCHA...

Отзывы: