43
C
ERAMIC
B
AFFLE
I
NSTALLATION
:
1. Remove the front secondary air tube by placing a screwdriver (any style except flat head) into one
of the air holes and tapping it with a hammer/mallet to the left. Step 1 is only required on the insert
Left Ceramic Baffle
Right Ceramic Baffle
Figure 53: Installation of Ceramic Baffle.
Installation
F
AN
W
IRING
D
IAGRAMS
:
This appliance, when installed, must be electrically connected and grounded in accordance with local
codes or in the absence of local codes, with the current CSA C22.1 CANADIAN ELECTRICAL CODE. Part
1, SAFETY STANDARDS FOR ELECTRICAL INSTALLATIONS, or THE NATIONAL ELECTRICAL CODE ANSI
/ NFPA 70 in the USA.
CAUTION Label all wires prior to disconnection when servicing controls. Wiring errors
can cause improper and dangerous operation. Verify proper operation after servicing.
This is a basic wiring diagram for the option fan installation.
1) Plug the fan assembly into a three (3) prong (grounded) receptacle.
2) Turn the fan controller to the desired setting.
3) Once the unit has reached operating temperature, the fan temperature sensor will turn the fan on
automatically.
4) When the unit cools down the fan temperature sensor will shut the fan off automatically.
models.
2. Slide the right ceramic baffle in
over the secondary air tubes at the
top of the firebox. The tab must be
on the top and pointing towards
the center and the smooth side is
to face down.
3. Hook the outside edge of the baffle
over the top of the secondary air
chamber. This will make room
to for the installation of the left
ceramic baffle.
4. Slide the left ceramic baffle in
over the secondary air tubes. The
tab must be on the bottom and
pointing towards the center and
the smooth side is to face down.
5. Pull the baffles together in the
middle so the right tab rests on top
of the left tab. Ensure the baffles
are flush with the back and both
sides of the firebox.