User Manual
ODE Mk2 MANUAL
For latest version visit:
May 18
ID: 3275345 Rev:33
Page|
5
Art-Net Send Test
NMU can also be used to troubleshoot the DMX output
on your ODE. Art-Net Test can be accessed from the top
menu: Art-net
→
Art-net
Test
When first opened, the Art-Net is set to Disabled, please
set it to Enabled, and then you can use either the DMX
faders to test one or more DMX channels, or use the test-
patterns from the options available.
Please set the ODE to be Art-Net output and on the same
universe as being used to send Art-Net from NMU.
DMX wiring
5pin DMX OUT/ DMX IN:
•
Pin 1: Ground
•
Pin 2: Data -
•
Pin 3: Data +
•
Pin 4: NC
•
Pin 5: NC
Any suitable 3 to 5pin DMX adaptor can be used to
connect to 3pin DMX cables or fixtures. Please note the
pinout, before connecting to any non-standard DMX
connector.
Specifications
Due to continuous improvements and innovations of all
ENTTEC products, specifications and features are subject to
change without notice.
Item
Value
Input Voltage
7V - 12V DC
Nominal Cur-
rent
800 mA
Wattage
5.6W
Supported
Protocols
DMX512A / RDM / ArtNet / sACN /
ESP
Width:
130mm / 5.12”
Height
40mm / 1.58”
Depth
60mm / 2.36”
Weight
0.26 kg / 0.58 lbs
Shipped Weight
0.48 kg / 0.68 lbs
Operating
Environment
0° to 50°C
Connectors
1x RJ45 Ethercon Connection
1x Male DMX XLR 5pin
1x Female DMX XLR 5pin
1x DC Jack
Ordering Information
The ENTTEC ODE and compatible products can be ordered
from our website or through your ENTTEC dealer.
PN
Description
70405
ODE Mk2
70406
ODE Mk2 with POE
79111
Replacement Power Supply Kit
70041
Truss Mounting Yoke (not included)
70029
3-pin female to 5-pin male adapter
70030
5-pin female to 3-pin male adapter