OCTO MK2 (71521)
Visit the ENTTEC website for the latest version.
..
USER MANUAL
20
|
ID: 5928937
Document Updated: Jan 2022
Using web interface
The reset to defaults command can be found under the Settings tab of the OCTO.
Once the command is pressed, a pop-up would appear as shown in the image below:
Using the reset button
The reset button restores the network configuration of the OCTO to factory defaults:
To reset to factory defaults, the following procedure must be performed:
Power off the unit
Press and hold the Reset button.
While holding the Reset button, power up the unit, and keep holding the button for 3 seconds.
Release the Reset button once the status led starts blinking red.
Tips and guidelines
I’m unable to connect to the OCTO web interface:
Ensure that the OCTO and your computer are on the same subnet
To troubleshoot:
1.
Connect the OCTO directly to your computer using a Cat5 cable and power it on.
2.
Give your computer a Static IP address (e.g.: 192.168.0.20)
3.
Change computer Netmask to (255.0.0.0)
4.
Open NMU and select the network adaptor connected to your OCTO.
5.
If you have multiple networks (WiFi etc.), please try to disable all other networks except the one OCTO
is connected to.
6.
Once NMU finds the OCTO, you will be able to open the device webpage and configure it.
7.
Factory Reset the device using the button if following the steps above and navigate to the OCTO’s default
IP if this did not resolve the issue.
Is it possible to run pixel tapes and dots using different protocols and voltages at the same time?
No, only one LED protocol can be selected to drive the output at a given time.
What is the minimum DC voltage for powering the OCTO?
The minimum DC voltage the OCTO requires to run is 4v.