OCTO MK2 (71521)
Visit the ENTTEC website for the latest version.
..
USER MANUAL
19
|
ID: 5928937
Document Updated: Jan 2022
Updating firmware
It is strongly recommended that the OCTO is updated with the latest firmware, available on the ENTTEC
website. This firmware can be loaded to the driver through its web interface by carrying out the following
steps:
1.
Browse and select the correct firmware version on your PC.
2.
Press the Update Firmware button.
Once the firmware update is complete, the device will reboot while the web interface displays the message
shown in the image below:
Reset to factory defaults
Factory resetting the OCTO results in the following:
Resets the device name.
Enables DHCP.
Static IP Address reset (IP address = 192.168.0.10).
Resets the gateway IP.
Netmask is set to 255.0.0.0
Restores standalone shows to factory default.
Direct mode is activated.
Input protocol is set to Art-Net.
LED protocol is set as WS2812B.
Pixel color is set to RGB.
Both ports are set to output 4 universes. The start universe for output 1 & output 2 is set as 0.
Mapped pixels value is set to 680 pixels.
DMX start address is set to 0.
APA-102 global intensity set to maximum.