Copyright © Entrypass Corporation
ENTRYPASS TECHNICAL – WIRING GUIDE
Communication
Data Signal
Max Distance
Description
PC to PCC
RS232
10m
(30 ft)
22 AWG, 2 Pairs, Shielded
PCC to Serial
Controller
RS485
1000m
(3000 ft)
22 AWG, 2 Pairs, Shielded &
Twisted Pair
Network Controller or
Reader to PC or
Network Switch
Network
100m
(300 ft)
24 AWG, 4 Pairs (Cat 5e)
Controller to Reader
Wiegand
30m
(100 ft)
22 AWG, 2 Pairs, Shielded &
Twisted Pair
Controller to Electro-
Magnetic Lock
Power
30m
(100 ft)
18 AWG, 1 Pair
Controller to Push
Button
Contact
30m
(100 ft)
22 AWG, 1 Pair
Controller to Door
Sensor
Contact
30m
(100 ft)
22 AWG, 1 Pair
Controller to Controller
for Cross-Board
Interlock
Contact
100m
(300 ft)
22 AWG, 1 Pair
Serial Controller – S3150, S3200, S3400
Network Controller – N5150, N5200, N5400
Cabling Information