background image

 

 

Overview

 

 

 

 

5

 

2

 

Overview

 

 

 

FIGURE 2-1

 

 
 

 

Item

 

Connection Detail

 

 

Power Supply Unit (PSU)

 

Section 3 - Page 6

 

 

Network Switch

 

 

 

Apartment Station Connections

 

Section 5- Page  

 

 

Apartment Station Network Power 
Isolation Switch

 

 

 
 

 

A

 

B

 

C

 

D

 

A

 

B

 

C

 

D

 

Содержание PRO-SW6

Страница 1: ...PRO SW6 12 Installation Guide Issue 002 ...

Страница 2: ...8th Edition Regulation 444 MEASURES AGAINST ELECTROMAGNETIC DISTURBANCES imposes requirements for segregation of circuits IET Wiring Regulations 18th Edition Regulation 528 PROXIMITY TO WIRING SYSTEMS TO OTHER SERVICES imposes requirements for segregation of door entry access control circuits Band I 230VAC mains circuits Band II and other higher voltage circuits IET Wiring Regulations 18th Edition...

Страница 3: ...Contents 3 Contents 1 Cable Specification 4 Typical Configuration 4 2 Overview 5 3 Power Supply 6 Mains Supply Connections 6 4 UPS Battery Connections 7 5 Apartment Station Connections 7 ...

Страница 4: ...c operation of equipment The specification below shows the minimum cable requirements allow for extra cabling if redundancy is required Connection Cable A Switch to each Apartment Station 1x Cat5e or Cat6 B Between Switches Up to 32 can be cascaded 1x Cat5e or Cat6 Typical Configuration FIGURE 1 1 NOTE For setup of the Apartment Station refer to the PRO AS Installation Guide PRO AS Apartment Sta o...

Страница 5: ...5 2 Overview FIGURE 2 1 Item Connection Detail Power Supply Unit PSU Section 3 Page 6 Network Switch Apartment Station Connections Section 5 Page Apartment Station Network Power Isolation Switch A B C D A B C D ...

Страница 6: ...to Internal Devices Backup Battery Connections for 2x Sealed Lead Acid Batteries Connected in Series See Section 4 Output Voltage Adjustment SYSTEM VOLTAGE 27 6VDC Always test the output voltage Only adjust if required Fuse Holder Mains Supply Cable from Fused Spur 1 5mm Twin Earth LIVE BROWN NEUTRAL BLUE EARTH GREEN YELLOW Sheath A B C D E A B L N E B B L N E E A C D A ...

Страница 7: ...5 1 Connection Cable Type Detail Ethernet to Apartment Stations 1 6 1x Cat5e or Cat6 to each Apartment Station RJ45 T568B Ethernet to Apartment Stations 12 PRO SW12 ENC only 1x Cat5e or Cat6 to each Apartment Station RJ45 T568B FIGURE 5 2 EIA TIA 568B COLOUR CODE A B Up to 90M A B FIGURE 4 1 12V AH SEALED LEAD ACID TYPE RECHARGABLE BATTERY 12V AH SEALED LEAD ACID TYPE RECHARGABLE BATTERY 24V BATTE...

Страница 8: ...Entrotec Ltd 5 Ashwood Court Oakbank Livingston EH53 0TL Telephone 01506 886 230 Support 01506 886 235 www entrotec com ...

Отзывы: