Entrotec PRO-SW6 Скачать руководство пользователя страница 2

Legal

 

 

2

 

Legal and Copyright Notice

 

Entrotec regularly develop and enhance product lines, these changes will be included in the latest 
documentation.  Whilst every effort has been made to ensure the accuracy of the information 
supplied herein, Entrotec is not responsible for any errors or omissions.  Many of the images 
shown are for illustration purpose only.  The actual product may vary due to product enhancement 
or custom configurations.  The materials contained in this document are protected and may be 
subject to intellectual property rights.

 

 

Copyright 2021 Entrotec Limited.  All rights reserved.

 

Installation Specification

 

It is the responsibility of the installer to follow Entrotec’s installation and cable specification as well 
as ALL relevant wiring regulations.  Failure to comply with Entrotec’s installation and cable 
specification may result in erratic operation of equipment and could invalidate any warranty.

 

 

Installations must comply with the following applicable standards:

 

 

BS 7671

: Requirements for electrical installations.  IET Wiring Regulations 18th Edition.

 

 

The Electricity at Work Regulations 1989

 

 

ANSI/TIA-568.0-D

: Generic Telecommunications Cabling for Customer Premises.

 

 

ANSI/TIA-568.1-D

: Commercial Building Telecommunications Cabling Standard.

 

 

IET Wiring Regulations 18th Edition: Regulation 444 (MEASURES AGAINST ELECTROMAGNETIC 
DISTURBANCES) imposes requirements for segregation of circuits.

 

 

IET Wiring Regulations 18th Edition: Regulation 528 (PROXIMITY TO WIRING SYSTEMS TO OTHER 
SERVICES) imposes requirements for segregation of door entry / access control circuits (Band I), 
230VAC mains circuits (Band II) and other higher voltage circuits.

 

 

IET Wiring Regulations 18th Edition: Regulations 541 and 542 impose requirements for earthing 
and bonding conductors.  Ensure ALL metalwork is bonded to the buildings earth, this includes call 
panels, exit switches, cabinets and metal conduit.  Ring terminals and earth points are provided on 
call panels and cabinets to terminate earth cables, ensure these connections are made.

 

 

  

 

 

 

WARNING - ISOLATION OF ELECTRICAL EQUIPMENT

 

In compliance with 

The Electricity at Work Regulations 1989,

 electrical equipment should be 

made dead to prevent danger while work is carried out on or near that equipment.  No person 
shall be engaged in any work activity on or so near any live conductor.

 

 

Warranty and Support

 

Entrotec systems are renowned for their reliability and have a 2-year warranty on all Entrotec 
manufactured products as standard.  This warranty does not cover water damage, vandalism, 
mains electrical faults, lightning strikes, damage caused by miswiring or cable faults.

 

 

Entrotec offer complimentary training courses and telephone support:

 

01506 886 235 - 

8:30am to 5pm Mon-Thurs and 8:30am to 4pm Friday.

 

[email protected]

 

Содержание PRO-SW6

Страница 1: ...PRO SW6 12 Installation Guide Issue 002 ...

Страница 2: ...8th Edition Regulation 444 MEASURES AGAINST ELECTROMAGNETIC DISTURBANCES imposes requirements for segregation of circuits IET Wiring Regulations 18th Edition Regulation 528 PROXIMITY TO WIRING SYSTEMS TO OTHER SERVICES imposes requirements for segregation of door entry access control circuits Band I 230VAC mains circuits Band II and other higher voltage circuits IET Wiring Regulations 18th Edition...

Страница 3: ...Contents 3 Contents 1 Cable Specification 4 Typical Configuration 4 2 Overview 5 3 Power Supply 6 Mains Supply Connections 6 4 UPS Battery Connections 7 5 Apartment Station Connections 7 ...

Страница 4: ...c operation of equipment The specification below shows the minimum cable requirements allow for extra cabling if redundancy is required Connection Cable A Switch to each Apartment Station 1x Cat5e or Cat6 B Between Switches Up to 32 can be cascaded 1x Cat5e or Cat6 Typical Configuration FIGURE 1 1 NOTE For setup of the Apartment Station refer to the PRO AS Installation Guide PRO AS Apartment Sta o...

Страница 5: ...5 2 Overview FIGURE 2 1 Item Connection Detail Power Supply Unit PSU Section 3 Page 6 Network Switch Apartment Station Connections Section 5 Page Apartment Station Network Power Isolation Switch A B C D A B C D ...

Страница 6: ...to Internal Devices Backup Battery Connections for 2x Sealed Lead Acid Batteries Connected in Series See Section 4 Output Voltage Adjustment SYSTEM VOLTAGE 27 6VDC Always test the output voltage Only adjust if required Fuse Holder Mains Supply Cable from Fused Spur 1 5mm Twin Earth LIVE BROWN NEUTRAL BLUE EARTH GREEN YELLOW Sheath A B C D E A B L N E B B L N E E A C D A ...

Страница 7: ...5 1 Connection Cable Type Detail Ethernet to Apartment Stations 1 6 1x Cat5e or Cat6 to each Apartment Station RJ45 T568B Ethernet to Apartment Stations 12 PRO SW12 ENC only 1x Cat5e or Cat6 to each Apartment Station RJ45 T568B FIGURE 5 2 EIA TIA 568B COLOUR CODE A B Up to 90M A B FIGURE 4 1 12V AH SEALED LEAD ACID TYPE RECHARGABLE BATTERY 12V AH SEALED LEAD ACID TYPE RECHARGABLE BATTERY 24V BATTE...

Страница 8: ...Entrotec Ltd 5 Ashwood Court Oakbank Livingston EH53 0TL Telephone 01506 886 230 Support 01506 886 235 www entrotec com ...

Отзывы: