Section 1 – How to use the touch-screen
5 |
P a g e
1.3 Status screen
This screen presents useful information regarding the status of the control and
the measurements from the last weld. Access the
Status
screen by tapping on
the
i
icon on the banner of any menu.
Pos t‐hea t
Progra m
2
Force
100 lb
˄
Ready
1
2
3
4
5
6
Conducti on
35.5%
7
˅
2.00 kA
5.00 kA
1.00 kA
Pre‐heat
Ma i n Hea t
i
Status
1
This field displays the control status. Tapping on this field will display
a message screen giving the option to reset the status.
2
Pre-heat current from the last weld
3
Main heat current from the last weld
4
Post-heat current from the last weld (
Extended Features
must be
enabled in the
Configuration
menu)
5
Program used for the last weld
6
Force measured from the last weld
7
Percent Conduction of the SCR from the last weld
Tap the
i
in the center of the banner to return to the previous screen.
Tap the