Section 3 – Menus
14 |
P a g e
3.2.6. Force menu
If
Force Profile
is not selected (or not shown) in the
Options
menu, the
Force menu will only include the items shown below.
The Force value shown below will be used for the entire duration of the
program:
Monitor
Force
˄
Low Limit
High Limit
5%
5%
Force
500 lb
˅
Wait for
Force
i
Force: Program 0
Force Menu without Force Profile
If
Force Profile
is selected in the
Options
menu, the Force menu will
include the items shown below. Using the Force Profile provides the
opportunity to use different force values in each program interval.
500 lb
Post‐heat
500 lb
Hold
500 lb
Main Heat
450 lb
Cool 2
500 lb
Downslope
˅
˄
Low Limit
High Limit
5%
5%
Monitor
Force
Wait for
Force
Squeeze
500 lb
Pre‐heat
600 lb
Cool 1
500 lb
Upslope
550 lb
i
Force: Program 0
Force Menu with Force Profile