Section 3 – Menus
18 |
P a g e
Features
Electrodes WAV
Motor
Standard
n/a
AV1
n/a
AV1 is
automatically
assigned
Extended
(spot)
Single
AV1
n/a
AV1 is
automatically
assigned
Multi
AV1 – AV8
n/a
Any AV output
may be assigned
Extended
(seam)
Single
AV1
AV2
AV1 and AV2 are
automatically
assigned
Multi
AV1 – AV8 AV1 – AV8 Any AV output
may be assigned
3.2.7.1. WAV
The WAV (Weld Air Valve) turns on at the start of the sequence
and turns off at the end of Hold. Valves not being used for the
WAV function may be used as AUX valves. WAV settings will
always override any AUX setting assigned to the same valve.
3.2.7.2. MOTOR
This feature is available in
Seam
mode only. For normal seam
welding, the MOTOR output turns on according to the
2
nd
Stage
setting in the
Configuration
menu and turns off at the start of the
Hold interval. If the
Roll-spot
option is
selected, the MOTOR
output operates during the Off interval only. Valves not being used
for the MOTOR function may be used as AUX valves. MOTOR
settings will always override any AUX setting assigned to the same
valve.
3.2.7.3. AUX
An AUX valve may be programmed to turn on during any interval in
the welding sequence.
Repeat mode
must be enabled in the
Options
menu to access the OFF interval. WAV and MOTOR
settings will always override any AUX setting assigned to the same
valve.
Extended