![Entrematic SPRINT L Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/entrematic/sprint-l/sprint-l_technical-manual_2415254020.webp)
50
IP2185EN - 2015-09-21
16. Adjustments
Description
OFF
ON
DIP1
Push & Go function.
The manual pushing of the door
activates an automatic opening
operation.
Disabled.
Enabled.
Use the SPRINT SET card to dis-
able the motor closure thrust.
DIP2
Electric lock selection.
Disabled.
Enabled.
When it is about 20° from the
closing stop, the door increases
its force/speed to ensure correct
closure on the electric lock or
electric block.
DIP3
LowEnergy function.
Refer to the Requisites chapter
(page 21) for doors for the tran-
sit of disabled people.
Disabled.
Enabled.
DIP4
Selecting opening direction.
The opening direction is intend-
ed by viewing the automation
from the side being examined.
SEE FIGURE
SEE FIGURE
DIP5
Selection of the type of arm.
SBA articulated arm.
SEE FIGURE
SBS sliding arm
BRAS articulated arm
SEE FIGURE
DIP6
Selecting the G1 output mode
Enable the test on the
safety sensor.
Positive pulse at the start of each
opening operation.
SBA arm
DIP4
DIP5
SBS - BRAS arm
DIP4
DIP5
ON
OFF
OFF
ON
OFF
OFF
ON
ON
The trimmers and DIPs affect the force limiting safety function.
They must be set as instructed. If not, the modifications will not be accepted and the IN LED
will flash.
ǩ SUHVVWKH23(1NH\IRUVHFRQGVWKH,1/('ȍDVKHV
ǩ DGMXVWWKHWULPPHUVDQGVHOHFWWKH',3VZLWKLQWKHPLQXWHWLPHOLPLW
ǩ WRFRPSOHWHWKHSURFHGXUHSUHVVWKH23(1NH\IRUVHFRQGVRUZDLWIRUWKHWLPHOLPLWWR
expire.
16.1 Enabling procedure
16.2 Dip-switches
i
NB: when the door is closed, a closure thrust is maintained by the motor.
Use the additional SPRINT SET card to disable the motor closure thrust.