14. Outputs and accessories
Output
Value - Accessories
Description
0 1
+
-
24V 0.3 A
Power supply to accessories.
Output for power supply to external accessories.
NB: the maximum absorption of 0.3 A corresponds to the sum of
all terminals 1.
-LK+
12V 1.2 A
Electric lock.
Output for electric lock or electric block power supply.
The power supply to the electric lock has a lead time of 0.1 s and a
duration of 1 s.
G1 0
-
+
24V 30 mA
General purpose output.
With DIP6=ON, the output supplies a positive pulse at the start of each
opening operation.
With DIP6=OFF, a test is activated on the safety sensor when each
opening operation is completed. If the test fails, the SA LED comes on
and the test is repeated.
SWITCH
ON/OFF switch.
Switch for turning on and off.
When the device is switched ON, the first operation is performed
with the acquisition of the stop positions.
When it is switched OFF, the line power supply and batteries (if in-
stalled) are disconnected from the control panel.
WARNING: jumper the contact if it is not used.
COM
SPRINTSET
This defines the G1 output operating mode using the SPRINTSET
customisation module.
WARNING: the module must be inserted and removed with the
power supply disconnected.
MOT
+
-
ENC
Motor-encoder connection.
Connect the motor and encoder to the control panel by means of
the cables supplied.
SPRINTBAT
1 x 12V 1.2 Ah
Anti-panic mode batteries.
With the mains power supply off, the automation will carry out an
opening operation at low speed. When the door is open, the power
supply is disconnected from the control panel.
To charge the batteries, connect the mains power and the battery
kit at least 30 minutes before starting up the system.
WARNING: for charging purposes, the battery kit must be connect-
ed to the control panel at all times. Periodically check the efficiency
of the battery kit.
Continuous mode batteries.
With the mains power supply off, the battery kit will guarantee con-
tinuous operating.
To charge the batteries, connect the mains power and the battery
kit at least 30 minutes before starting up the system.
WARNING: for charging purposes, the battery kit must be connect-
ed to the control panel at all times. Periodically check the efficiency
of the battery kit.