Operation mode selectors
The door functions are set with different operate mode selectors.
The operation mode selector is available with 5 buttons (plus RESET).
The key on the PS-6 mode selector must always be removed on emergency escape doors after
changing settings.
Functions
OPEN, AUTO PARTIAL, AUTO, ONE WAY and OFF functions can be obtained.
Function
Text
Symbol
The door is permanently open. The door can be moved by hand
e.g. for window cleaning. All activation units except for the emer-
gency push button (if fitted) are disconnected.
OPEN
Two-way traffic, AUTO PARTIAL is obtained. The door can be
opened partially with the inner and outer activation units and with
a key switch (if fitted). With an emergency push-button the door
opens fully.
AUTO
PARTIAL
Two-way traffic, normal operation of the door. The door can be
opened with the inner and outer activation units and with a key
switch/emergency push-button (if fitted).
AUTO
Passage from inside only. The door is normally locked if an elec-
tromechanical locking device has been fitted. The door can only
be opened with the inner activation unit or with a key
switch/emergency push-button (if fitted).
ONE
WAY
This function is only used on emergency escape doors after it is
certain that all people have left the building.
The door cannot be opened with inner and outer activation units.
The door is locked if an electromechanical locking device has been
fitted. The door can be opened partially with a key switch (if fitted).
With an emergency pushbutton (if fitted) the door opens fully.
The door can also be opened partially from the operation mode
selector if the arrow down button is held for 2 seconds. No access
code is necessary for this and the key impulse is indicated by briefly
showing a blue light to the left of the open symbol or text and
then a flashing blue light to the left of the closed symbol or text
for another 15 seconds.
OFF
By briefly pushing the green dot with a narrow object, the door
operator will make a RESET function with a system test. The door
will return to the closed position (if not in operation mode selec-
tion OPEN or if an error is present) and is then ready for normal
operation.
RESET
Turn the key clockwise to the position “R” (six o’clock) and insert
a narrow object in the small hole on the operation mode selector
and push briefly. Then turn the key counter-clockwise back to the
requested setting and the door operator will make a RESET function
with a system test. The door will return to the closed position (if
not in operation mode selection OPEN or if an error is present)
and is then ready for normal operation.
Note! The key cannot be removed in the "R" position.
RESET
2
3
5
4
A
A
B
SECTION A-A
DETAIL B
SCALE 5 : 1
* Assembled on site
1
pcs. PLASTIC BAG 150x200
701002
7
1
pcs. WIRING HARNESS MS BASIC RJ45 CABLE
1008972 *
6
1
pcs. Software MS BwL
1007926
5
1
pcs. PCB Assembly Mode Selector Basic with LED
1008140
4
1
pcs. Pin flush mounted MS
1008773
3
1
pcs. STICKER EM SL 40x80 5 POS SYMBOL
1010411 *
2
2
pcs. SCREW ISO 7049 C (RTS) ST2.9x16 FZB 4.8
724462 *
1
1
pcs. FRAME 40x80 Flush
1008102
Pos. Qty. Unit Description
Art.no.
Remark
All rights in and to this material are the sole property of ASSA ABLOY Entrance Systems AB. Copying, scanning, alterations or modifications are expressly forbidden without the prior written consent of ASSA ABLOY Entrance Systems AB.
©
0.4
12-586
Date
Done
CM-No.
Change
No.
SEJOB
-
1 (1)
Sheet
Remark
Date
Size
Rev.
Drawing No.
Drawn
Status
Material
Scale
ISO 2768
Surface treatment
General tolerance
Description
Proj. method
A3
-
1:1
SEJOB
40x80 FLUSH 5 SYMB
MODE SELECTOR EM SL
0.4
1010412
Draft
ASSA ABLOY Entrance Systems AB
New article
1009216-EMEI-4.0
Issue 2016-03-14