35
IP1851EN - 2014-09-30
Output
Value - Accessories
Description
0
-
1
+
24 V 0,3 A
Accessories power supply.
Power supply output for external accessories, including automa-
tion status lamps.
AUX
SOFA1-SOFA2
GOPAV
The control panel is fitted with a housing for a plug-in card, such as
radio receivers, magnetic loops, etc.
Operating of the plug-in card is selected by DIP1A.
WARNING: the plug-in cards must be inserted and removed with
the power supply disconnected.
COM
STORAGE
MODU�E
The storage module allows remote controls to be stored and the
type of control panel application to be defined (see TECHNICA�
SPECIFICATIONS on page 4).
If the control panel is replaced, the storage module being used can
be inserted in the new control panel.
WARNING: the storage module must be inserted and removed with
the power supply disconnected.
BAT
BATK3
2x12 V 2Ah
Barrier operation.
The batteries are kept charged when the power supply is on. If the
power supply is off, the panel is powered by the batteries until the
power is re-establish or until the battery voltage drops below the
safety threshold. The panel turns off in the last case.
WARNING: the batteries must always be connected to the control
panel for charging. Periodically check the efficiency of the batteries.
N.B.: the operating temperature of the rechargeable batteries is
approxi5°C/+40°C.
1 5 9 13 20
24 V 3 W
Automation status lamp (proportional)
The light goes off when the automation is closed.
The light comes on when the automation is open.
The light flashes with a variable frequency while the automation is
operating.
14 0
�AMPH
24 V 25 W
Flashing light.
WITH DIP5A=OFF it is activated during the opening and closing
operations.
C NO
L N
230 V~ 400 W
External courtesy light.
With DIP5A=OFF, a courtesy light can be connected in series to the NO
contact, which activates for 180 s on each opening (total or partial),
step-by-step and closing command.
0
14
NO
C
�AMPH
24 V 25 W
Flashing light.
WITH DIP5A=ON it is activated during the opening and closing
operations.
WARNING: use a double insulated cable
�. Barrier outputs and accessories