EDSL450 User manual
8
1.5
Program selector switch
The Program switch is used to select the required program. The program switch can be installed close
to the door or at another location in the building.
1.6
Program selection and interaction
The program switch is used to select the program that will be used for the sliding door.
1.7
Program selection
Selection is done with a key switch. The switch can be positioned in six different positions, five of
which are programs and one is used for error reporting and reset (position F).
See the table below for the list of programs that can be selected. To prevent multiple changes to the
selected program while switching from one to another, the switch has to remain stationary for more
than two seconds before the new program is activated.
Position
Function
A
Program close
. Door is closed and locked. Sensors will not open the door. Only
porter input can be used to open the door.
B
Program exit-only + full open
. Door opens on activation of inside motion sensor.
An open door will remain open if either inside or outside presence sensor is
active. Door is opened to the full open position.
C
Program aut full open.
The door will open on activation of all sensors,
inside or outside. Door is opened to full open position.
D
Program aut reduced open
. The door will open on activation of all
sensors, inside or outside. Open position will be to the reduced open position or
full open position depending on the activator. This program cannot be used in
escape routes.
E
Program open + full open.
Door opens and remains open during this program
regardless of sensors active.
F
Error reporting and reset.
When the controller has a warning or is in error, placing
the switch in this position will cause program switch to display the warning or
error code.
A
B
C
D
E
F