Enterasys SecureStack C2 C2RPS-POE Скачать руководство пользователя страница 4

ii 

Regulatory Compliance Information

Federal Communications Commission (FCC) Notice

This

 

device

 

complies

 

with

 

Part

 

15

 

of

 

the

 

FCC

 

rules.

 

Operation

 

is

 

subject

 

to

 

the

 

following

 

two

 

conditions:

 

(1)

 

this

 

device

 

may

 

not

 

cause

 

harmful

 

interference,

 

and

 

(2)

 

this

 

device

 

must

 

accept

 

any

 

interference

 

received,

 

including

 

interference

 

that

 

may

 

cause

 

undesired

 

operation.

NOTE:

This

 

equipment

 

has

 

been

 

tested

 

and

 

found

 

to

 

comply

 

with

 

the

 

limits

 

for

 

a

 

class

 

A

 

digital

 

device,

 

pursuant

 

to

 

Part

 

15

 

of

 

the

 

FCC

 

rules.

 

These

 

limits

 

are

 

designed

 

to

 

provide

 

reasonable

 

protection

 

against

 

harmful

 

interference

 

when

 

the

 

equipment

 

is

 

operated

 

in

 

a

 

commercial

 

environment.

 

This

 

equipment

 

uses,

 

generates,

 

and

 

can

 

radiate

 

radio

 

frequency

 

energy

 

and

 

if

 

not

 

installed

 

in

 

accordance

 

with

 

the

 

operator’s

 

manual,

 

may

 

cause

 

harmful

 

interference

 

to

 

radio

 

communications.

 

Operation

 

of

 

this

 

equipment

 

in

 

a

 

residential

 

area

 

is

 

likely

 

to

 

cause

 

interference

 

in

 

which

 

case

 

the

 

user

 

will

 

be

 

required

 

to

 

correct

 

the

 

interference

 

at

 

his

 

own

 

expense.

WARNING:

Changes

 

or

 

modifications

 

made

 

to

 

this

 

device

 

which

 

are

 

not

 

expressly

 

approved

 

by

 

the

 

party

 

responsible

 

for

 

compliance

 

could

 

void

 

the

 

user’s

 

authority

 

to

 

operate

 

the

 

equipment.

Industry Canada Notice

This

 

digital

 

apparatus

 

does

 

not

 

exceed

 

the

 

class

 

A

 

limits

 

for

 

radio

 

noise

 

emissions

 

from

 

digital

 

apparatus

 

set

 

out

 

in

 

the

 

Radio

 

Interference

 

Regulations

 

of

 

the

 

Canadian

 

Department

 

of

 

Communications.

Le

 

présent

 

appareil

 

numérique

 

n’émet

 

pas

 

de

 

bruits

 

radioélectriques

 

dépassant

 

les

 

limites

 

applicables

 

aux

 

appareils

 

numériques

 

de

 

la

 

class

 

A

 

prescrites

 

dans

 

le

 

Règlement

 

sur

 

le

 

brouillage

 

radioélectrique

 

édicté

 

par

 

le

 

ministère

 

des

 

Communications

 

du

 

Canada.

Class A ITE Notice

WARNING:

This

 

is

 

a

 

Class

 

A

 

product.

 

In

 

a

 

domestic

 

environment

 

this

 

product

 

may

 

cause

 

radio

 

interference

 

in

 

which

 

case

 

the

 

user

 

may

 

be

 

required

 

to

 

take

 

adequate

 

measures.

 

Clase A. Aviso de ITE

ADVERTENCIA:

 

Este

 

es

 

un

 

producto

 

de

 

Clase

 

A.

 

En

 

un

 

ambiente

 

doméstico

 

este

 

producto

 

puede

 

causar

 

interferencia

 

de

 

radio

 

en

 

cuyo

 

caso

 

puede

 

ser

 

requerido

 

tomar

 

medidas

 

adecuadas.

Klasse A ITE Anmerkung 

WARNHINWEIS:

 

Dieses

 

Produkt

 

zählt

 

zur

 

Klasse

 

A

 

(

 

Industriebereich

 

).

 

In

 

Wohnbereichen

 

kann

 

es

 

hierdurch

 

zu

 

Funkstörungen

 

kommen,

 

daher

 

sollten

 

angemessene

 

Vorkehrungen

 

zum

 

Schutz

 

getroffen

 

werden.

 

Product Safety

This

 

product

 

complies

 

with

 

the

 

following:

 

UL

 

60950,

 

CSA

 

C22.2

 

No.

 

60950,

 

73/23/EEC,

 

EN

 

60950,

 

IEC 60950.

Seguridad del Producto

El

 

producto

 

de

 

Enterasys

 

cumple

 

con

 

lo

 

siguiente:

 

UL

 

60950,

 

CSA

 

C22.2

 

No.

 

60950,

 

73/23/EEC,

 

EN 60950,

 

IEC 60950.

Produktsicherheit 

Dieses

 

Produkt

 

entspricht

 

den

 

folgenden

 

Richtlinien:

 

UL

 

60950,

 

CSA

 

C22.2

 

No.

 

60950,

 

73/23/EEC,

 

EN 60950,

 

IEC 60950.

 

Содержание SecureStack C2 C2RPS-POE

Страница 1: ...xx indicates a SecureStack C2 PoE non compliant device and is not compatible with this power system Precauci n La fuente de poder C2RPS POE no es compatible con switches SecureStack C2 que no cumplan...

Страница 2: ......

Страница 3: ...rasys Networks Inc 50 Minuteman Road Andover MA 01810 2005 Enterasys Networks Inc All rights reserved Part Number 9033995 01 April 2005 ENTERASYS ENTERASYS NETWORKS ENTERASYS MATRIX LANVIEW MATRIX NET...

Страница 4: ...al apparatus does not exceed the class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications Le pr sent a...

Страница 5: ...entspricht den folgenden Richtlinien 47 CFR Parts 2 and 15 CSA C108 8 89 336 EEC EN 55022 EN 61000 3 2 EN 61000 3 3 EN 55024 AS NZS CISPR 22 VCCI V 3 VCCI Notice This is a class A product based on th...

Страница 6: ...td Nexus House Newbury Business Park London Road Newbury Berkshire RG14 2PZ England Conformance to Directive s Product Standards EC Directive 89 336 EEC EN 55022 EN 61000 3 2 EN 61000 3 3 EN 55024 EC...

Страница 7: ...VISIONS THE LICENSE THE DISCLAIMER OF WARRANTY AND THE LIMITATION OF LIABILITY IF YOU DO NOT AGREE TO THE TERMS OF THIS AGREEMENT OR ARE NOT AUTHORIZED TO ENTER INTO THIS AGREEMENT ENTERASYS IS UNWILL...

Страница 8: ...security controls as identified on the U S Commerce Control List or iii if the direct product of the technology is a complete plant or any major component of a plant export to Country Groups D 1 or E...

Страница 9: ...dge and agree that any breach of Sections 2 4 or 9 of this Agreement by You may cause Enterasys irreparable damage for which recovery of money damages would be inadequate and that Enterasys may be ent...

Страница 10: ...viii...

Страница 11: ...ackets and Installing in Rack 2 6 Connecting C2RPS POE Cable and AC Power Cord 2 7 Appendix A Specifications C2RPS POE Specifications A 1 C2RPS POE Redundant Power Supply Output Connector A 2 Complian...

Страница 12: ...fications 1 3 2 1 Contents of N POE Chassis Carton 2 2 2 2 C2RPS POE Status LED Indications and Recommended Actions 2 7 A 1 C2RPS POE Specifications A 1 A 2 C2RPS POE Redundant Power Supply Connector...

Страница 13: ...e This preface provides an overview of this guide and the SecureStack C2 manual set for PoE compliant devices and explains the symbols used throughout this manual Chapter 1 Introduction discusses the...

Страница 14: ...sical layer components The manuals can be accessed on the World Wide Web using the following URL http www enterasys com support manuals Caution The C2RPS POE power supply does not support non PoE comp...

Страница 15: ...ical Hazard Warns against an action that could result in personal injury or death due to an electrical hazard Riesgo Electrico Advierte contra una acci n que pudiera resultar en lesi n corporal o la m...

Страница 16: ...Conventions Used in This Guide xiv About this Guide...

Страница 17: ...lation Guide 1 1 1 Introduction This chapter provides the following information For information about Refer to page C2RPS POE Overview 1 2 C2RPS POE Status LED 1 2 Power Classifications and Deployment...

Страница 18: ...e following LED on RPS operating properly LED off RPS failed Power Classifications and Deployment Each PD has a Power Classification that indicates how much power it will consume as shown in Table 1 1...

Страница 19: ...ample of a C2RPS POE Power Configuration Note Use the highest power rating of PoE Power Class of each PD to calculate the maximum wattage For example such as 12 95 for a Class 0 device Table 1 1 Power...

Страница 20: ...n of any action s already taken to resolve the problem for example changing mode switches rebooting the unit etc The serial and revision numbers of all involved Enterasys Networks products in the netw...

Страница 21: ...lectrical Hazard Only qualified personnel should perform installation procedures Riesgo Electrico Solamente personal calificado debe realizar procedimientos de instalacion Elektrischer Gefahrenhinweis...

Страница 22: ...feet is recommended to prevent the C2RPS POE from sliding on a flat surface Installing the rubber feet is optional if you are installing the C2RPS POE in a rack To install the rubber feet proceed to...

Страница 23: ...POE Figure 2 1 C2RPS POE Bottom Rubber Feet Placement 4 Remove the protective strip from the back of one rubber foot and position it on a marked location and press firmly into place Repeat this proced...

Страница 24: ...rance space of 5 1 cm 2 0 in at the left right and rear of the switch Do not connect the switch to the AC power source until instructed to do so later in the installation process Precauci n Para asegu...

Страница 25: ...est tica Caution To ensure proper ventilation and prevent overheating leave a minimum clearance space of 5 1 cm 2 0 in at the left right and rear of the switch Do not connect the switch to the AC pow...

Страница 26: ...hed position the switch between the vertical frame members of the 19 inch rack as shown in Figure 2 4 Then fasten the C2RPS POE securely to the frame using four mounting screws user supplied Figure 2...

Страница 27: ...successful connection and the C2RPS POE is operating properly If the LED remains off refer to Table 2 2 for the recommended action 4 If two or more power supplies are being installed repeat steps 1 t...

Страница 28: ...page 1 4 for instructions Figure 2 5 C2RPS POE Cable Figure 2 6 Power Connector on C2RPS POE rear view 1 AC power plug 3 Redundant Power Supply connector 2 AC power connector AC LIN E 10 0 2 40 VA C 5...

Страница 29: ...ice 4 Switch device Redundant Power Supply connector 2 C2RPS POE Cable 5 AC power cord type varies depending on country 3 C2RPS POE Redundant Power Supply output connector 6 AC power outlet with groun...

Страница 30: ...Connecting C2RPS POE Cable and AC Power Cord 2 10 Installation...

Страница 31: ...ort specifications as follows For information about Refer to page C2RPS POE Specifications A 1 C2RPS POE Redundant Power Supply Output Connector A 2 Compliance Standards A 3 Table A 1 C2RPS POE Specif...

Страница 32: ...3 47 kg 7 63 lb 4 95 kg 10 89 lb MTBF 589 644 Hours at 25 C 77 F Environmental Operating Temperature 5 C to 40 C 41 F to 104 F Storage Temperature 30 C to 73 C 22 F to 164 F Operating Relative Humidi...

Страница 33: ...ber Function 1 50 V return 2 50 Vdc 3 12 Vdc output 4 12 Vdc output 5 12 Vdc output 6 12 Vdc output 7 Ground 8 Ground 9 No connection 10 RPS present 11 Status 1 12 Status 2 13 Power good 14 Ground Tab...

Страница 34: ...Compliance Standards A 4 Specifications...

Отзывы: