Using LANVIEW
SecureStack C2 Installation Guide 4-5
UP
Off
No valid connection to switch stack down
connector.
1.
Make sure the switch connected to
the stack down connector is
powered on.
2.
Replace cable with a known good
one.
3.
If the problem still exists, contact
Enterasys Networks for technical
support.
Green
Solid.
Valid connection to switch stack down
connector.
Blinking.
Information is being transferred
through the high-speed stacking cable.
None.
Manager
Off
Switch is operating as a Member in the stack.
None.
Green
Solid.
Switch is operating as the Manager of the
stack.
None.
RPS
Off
RPS not in use.
None.
Amber
Solid.
The switch internal power supply failed,
and the RPS is providing the proper power to
the switch.
If an RPS is connected to the switch and
should be providing power, perform the
following:
1.
Ensure the RPS is powered on.
2.
Ensure that the AC power cord to
the RPS is plugged in correctly and
that there is power at the AC power
source.
3.
Replace the power cord with a
known good one.
4.
Ensure the DC power cord from the
RPS to the switch is plugged in
correctly.
5.
If the problem persists, contact
Enterasys Networks for technical
support.
Table 4-1 LANVIEW LED Diagnostic Indications (continued)
LED
Color
State
Recommended Action
Содержание SecureStack C2 C2G124-48P
Страница 2: ......
Страница 12: ...x...
Страница 16: ...xiv...
Страница 20: ...Conventions Used in This Guide xviii Conventions Used in This Guide...
Страница 32: ...1000BASE T Network 2 4 Network Requirements...
Страница 72: ...Using the Reset Button 4 10 Troubleshooting...
Страница 80: ...Regulatory Compliance A 8 Specifications...