Using LANVIEW
4-4 Troubleshooting
Table 4-1 LANVIEW LED Diagnostic Indications
LED
Color
State
Recommended Action
CPU
Off
Power disconnected.
If the LED remains off after connecting
AC power or DC power from an RPS,
check the following:
1.
Make sure there is power at the
power source (AC source and RPS if
applicable).
2.
Replace the power cord with a
known good one or check the
continuity of the power cord.
3.
If the switch still does not power up,
the system may have a fatal error.
Contact Enterasys Networks for
technical support.
Red
Solid.
Boot-up failed.
If the LED remains red for several
minutes, the system may have a fatal
error. Contact Enterasys Networks for
technical support.
Amber
Solid.
Diagnostics are running.
If the LED remains amber for more than
several minutes, contact
Enterasys Networks for technical
support.
Blinking.
Code image is being downloaded.
None.
Green
Solid.
System is fully functional.
None.
Blinking.
Boot-up in process.
None.
DOWN
Off
No valid connection to switch stack up
connector.
1.
Make sure the switch connected to
the stack up connector is powered
on.
2.
Replace cable with a known good
one.
3.
If the problem still exists, contact
Enterasys Networks for technical
support.
Green
Solid.
Valid connection to switch stack up
connector.
Blinking.
Information is being transferred
through the high-speed stacking cable.
None.
Содержание SecureStack C2 C2G124-48P
Страница 2: ......
Страница 12: ...x...
Страница 16: ...xiv...
Страница 20: ...Conventions Used in This Guide xviii Conventions Used in This Guide...
Страница 32: ...1000BASE T Network 2 4 Network Requirements...
Страница 72: ...Using the Reset Button 4 10 Troubleshooting...
Страница 80: ...Regulatory Compliance A 8 Specifications...