Troubleshooting Checklist
4-8 Troubleshooting
Cannot contact the
switch through in-
band management.
IP address not assigned.
Refer to the
SecureStack B2 Configuration Guide
for the IP
address assignment procedure.
Port is disabled.
This is normal if the switch is a Member in a stack.
If operating as a standalone switch or as the Manager in a
stack, enable the port. Refer to the
SecureStack B2
Configuration Guide
for instructions to enable/disable ports.
No link to device.
Verify that all network connections between the network
management station and the device are valid and operating.
If the problem continues, contact Enterasys Networks for
technical support.
Port(s) goes into
standby for no
apparent reason.
Loop condition detected.
Verify that Spanning Tree is enabled. Refer to the
SecureStack B2 Configuration Guide
for the instructions to
set the type of STA.
Review the network design and delete unnecessary loops.
If the problem continues, contact Enterasys Networks for
technical support.
User parameters
(IP address, device
and module name,
etc.) were lost
when the switch
power was cycled.
Clear NVRAM was set using
CLI commands.
Reenter the lost parameters as necessary. Refer to the
SecureStack B2 Configuration Guide
for the instructions to
configure the switch using CLI commands.
If the problem continues, contact Enterasys Networks for
technical support.
Table 4-5 Troubleshooting Checklist (continued)
Problem
Possible Cause
Recommended Action
Содержание SecureStack B2 B2G124-48P
Страница 2: ......
Страница 12: ...x ...
Страница 21: ...x ...
Страница 25: ...xiv ...
Страница 29: ...Conventions Used in This Guide xviii About This Guide ...
Страница 41: ...1000BASE T Network 2 4 Network Requirements ...
Страница 81: ...Using the Reset Switch 4 10 Troubleshooting ...
Страница 89: ...Regulatory Compliance A 8 Specifications ...