Backplane Connections and Installation Rules
DFE-Platinum Series Hardware Installation Guide 3-5
Example 1 (
Figure 3-1
,
A)
Shows
the
chassis
fully
populated
with
DFE
‐
Platinum
modules
(7xxxxx).
These
modules
communicate
with
each
other
via
the
FTM2
chassis
backplane
and
act
as
a
single
switching
entity
with
one
IP
address.
The
DFE
‐
Platinum
modules
are
configured
using
a
Command
Line
Interface
set
of
commands.
Rule:
DFE
‐
Platinum
modules
can
be
installed
in
any
available
chassis
slot
in
the
Matrix
E7
chassis.
Example 2 (
Figure 3-1
,
B)
Shows
the
chassis
fully
populated
with
third
generation
modules
(6x3xx).
These
modules
can
also
be
installed
in
any
available
chassis
slot
in
the
Matrix
E7
chassis,
but
operate
as
individual
modules
with
separate
IP
addresses.
Each
module
is
configured
using
Local
Management.
Rule:
The
6x3xx
modules
can
be
installed
in
any
available
chassis
slot
in
the
Matrix
E7
chassis.
Example 3 (
Figure 3-1
, C)
Shows
chassis
slots
1
through
5
populated
with
first
and
second
generation
modules
(6x1xx
and
6x2xx).
If
a
6x1xx
or
6x2xx
series
module
is
installed
in
slot
6
or
7,
it
will
operate
in
standalone
mode
(no
backplane
connectivity).
Like
the
6x3xx
modules,
the
6x1xx
and
6x2xx
modules
operate
as
individual
modules
with
separate
IP
addresses,
and
each
one
is
configured
using
Local
Management.
Rule:
The
6x1xx
and
6x2xx
modules
can
communicate
with
each
other
when
they
are
installed
in
chassis
slots
1
through
5
in
the
Matrix
E7
chassis.
If
installed
in
slot
6
or
7,
they
operate
in
standalone
mode.
Example 4 (
Figure 3-1
,
D)
Shows
chassis
slots
1
through
5
populated
with
a
mix
of
6x1xx,
6x2xx,
and
6x3xx
modules
and
only
third
generation
modules
in
slots
6
and
7.
In
this
module
arrangement,
the
6x3xx
module
provides
a
proxy
bridge,
which
enables
the
6x1xx
and
6x2xx
modules
to
communicate
with
6x3xx
modules
in
slot
6
or
7.
If
more
than
one
6x3xx
module
is
installed
in
slots
1
to
5,
the
module
in
the
lowest
numbered
slot
performs
the
proxy
function
for
slots
6
and
7.
Therefore,
if
a
6x3xx
module
is
already
performing
the
proxy
function,
and
another
6x3xx
module
is
inserted
into
a
lower
numbered
slot,
connectivity
will
be
temporarily
interrupted,
as
the
new
board
takes
over
the
proxy
function.
When
a
6x3xx
module
in
a
lower
numbered
slot
is
removed,
and
there
is
a
6x3xx
module
in
a
higher
numbered
slot,
communication
is
not
interrupted.
For
Local
Management,
plugging
the
Local
Management
connection
into
the
6x3xx
modules
will
allow
management
connections
to
all
6x1xx,
6x2xx,
and
6x3xx
modules.
If
the
Local
Management
connection
is
to
a
6x1xx
or
6x2xx
board,
only
the
modules
in
the
first
five
slots
will
be
recognized
by
the
management
client.
Rule:
There
must
be
at
least
one
6x3xx
module
in
slots
1
through
5
to
enable
communications
between
the
6x1xx,
6x2xx,
and
6x3xx
modules.
Содержание Matrix 7H4382-25
Страница 2: ......
Страница 12: ...x...
Страница 16: ...xiv...
Страница 26: ...LANVIEW Diagnostic LEDs 1 6 Introduction...
Страница 54: ...Completing the Installation 3 26 Installation...
Страница 66: ...Regulatory Compliance A 4 Specifications...
Страница 76: ...Memory Locations and Replacement Procedures B 10 Mode Switch Bank Settings and Optional Installations...