Installing the Hardware
62
Enterasys X-Pedition 8000/8600 Getting Started Guide
X-Pedition 8000 DC Power Supply
Figure 25
shows the front view of an X-Pedition 8000 DC power supply.
Figure 25. Front view of an X-Pedition 8000 DC power supply
The X-Pedition 8000 DC power supply has a three-terminal wiring block on the front panel,
consisting of a positive (+) terminal, negative (-) terminal and a safety ground. The DC supply is
designed to be powered by a 48-volt DC source.
X-Pedition 8600 DC Power Supply
Figure 26
shows the front view of an X-Pedition 8600 DC power supply.
Figure 26. Front view of an X-Pedition 8600 DC power supply
The X-Pedition 8600 DC power supply has a five-terminal wiring block on the front panel. The
wiring block contains two positive (+) terminals, two negative (-) terminals, and a safety ground.
The DC supply is designed to be powered by a 48-volt DC source.
SSR-PS-8-DC
PWR
SN
!
To
be
installed
in
a
restricted
access
area
in
accordance
with
the
NEC
or
authority
having
jurisdiction.
See
manual
for
installation
instructions.
48/60V
14A
MAX
PWR
SSR-PS-16-DC
SN
48/60V
27A MAX
!
To be installed in a restricted
access area in accordance
with the NEC or authority
having jurisdiction.
See manual for installation
instructions.
Содержание 8000/8600
Страница 1: ...Getting Started Guide Revision Date 11 27 2002 8000 8600 9032552 16...
Страница 8: ...vi Enterasys X Pedition 8000 8600 Getting Started Guide...
Страница 116: ...104 Enterasys X Pedition 8000 8600 Getting Started Guide...
Страница 142: ...Index 130 Enterasys X Pedition 8000 8600 Getting Started Guide...