30
USER GUIDE
ENTEGRIS, INC.
INVUE INTEGRATED FLOW CONTROLLERS, MODELS NT6510, NT6520
Ordering Information
InVue Integrated Flow Controller
NT6510
6510- - - - - -
Primary/Secondary Seal
U3 = Kalrez 6375UP/Viton®
Setpoint Input Signal, Controller Type
A = 4–20 mA, continuous
B = 0–10 VDC, continuous
C = 0–5 VDC, continuous
K = 4–20 mA, batch
L = 0–10 VDC, batch
M = 0–5 VDC, batch
Electrical Connector Type
V06 = PVC-jacketed 6’ pigtail electrical cable
V12 = PVC-jacketed 12’ pigtail electrical cable
B06 = FEP-jacketed 6’ pigtail electrical cable
B12 = FEP-jacketed 12’ pigtail electrical cable
B30 = FEP-jacketed 30’ pigtail electrical cable
G01 = PVC-jacketed 1’ electrical cable terminated
with 14-pin Turck® connector**
G06 = PVC-jacketed 6’ electrical cable terminated
with 14-pin Turck connector**
Sensor Interface
P7 = CTFE (for acids, bases and
oxidants, typically)
P8 = PFA (for solvents and temperatures
>40°C, typically)
Note: Selection is dependent on application and chemical
media. Please contact Entegris for best selection.
Inlet/Outlet Port Connection***
F02 =
1
⁄
4
” Flaretek tube fitting
F03 =
3
⁄
8
” Flaretek tube fitting
F04 =
1
⁄
2
” Flaretek tube fitting
W02 =
1
⁄
4
” Super 300 type Pillar tube fitting
W03 =
3
⁄
8
” Super 300 type Pillar tube fitting
Flow Range*
TL = 0 –15 mL/min
TT = 0 –25 mL/min
T0 = 0 –50 mL/min
T1 = 0 –125 mL/min
T2 = 0 –250 mL/min
T3 = 0 –500 mL/min
T4 = 0 –1250 mL/min
Y0 = 0 –50 mL/min
Y1 = 0 –125 mL/min
Y2 = 0 –250 mL/min
Y3 = 0 –500 mL/min
Y4 = 0 –1250 mL/min
* Code “T” flow ranges are scaled to zero flow, measurement is from 10 –100% of full scale flow range.
Code “Y” flow ranges are scaled to zero flow, measurements is from 5 -100% of full scale flow range.
** For electrical connector types G01 and G06, a 14-pin mating cable is required for installation.
See “Electrical Mating Cables for InVue Flow Controllers NT6510 and NT6520 – Accessory” (p. 31)
for ordering information.
*** For PrimeLock and other options not shown here, please contact Entegris.
Product specified with a flared tube connection is packaged with two PVDF nuts.
For custom configurations and specifications, please contact Entegris.